Brand:

Danfoss 060-316466 KPI 35 Pressure Switch Gold Contacts

Description

060-316466: Danfoss KPI 35 liquid-capable switch with gold contacts

The KPI line is Danfoss’s answer to pressure switching on liquids as well as gases, and 060-316466 is the KPI 35 with a gold-plated contact set. Its setting range is -0.2 to 8.0 bar, the differential is adjustable from 0.4 to 1.5 bar, and the permissible operating pressure and maximum test pressure are both 18 bar. The product page lists water pumps and air compressors as the intended applications.

Unlike the KP, the KPI has an omega spring between bellows and contact system and a bellows that moves in proportion to pressure, a design the datasheet describes in its function section. The practical benefit is stable switching on liquid systems where pressure pulsates. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Reading the KPI 35 numbers

A 0.4 bar lower differential limit is handy on small pressure-boosting sets. Imagine a booster pump that should start at 2.0 bar and stop at 3.4 bar; the differential of 1.4 bar is inside the adjustable window. For a low-pressure application the datasheet adds that the restart pressure equals cut-out plus differential.

Because the maximum permissible pressure is 18 bar and the test pressure is also 18 bar, the unit is not designed for hydrostatic tests above the working limit; plan tests accordingly.

Specification table for 060-316466

Parameter Value
Code number 060-316466
Type KPI 35 single pressure switch
Setting range -0.2 to 8.0 bar
Differential 0.4 to 1.5 bar
Operating pressure 18 bar
Test pressure 18 bar
Connection G 1/4 A
Contacts SPDT, gold-plated silver
Gold low-level rating 1 to 30 mA at 5 to 30 V
Contact load after gold wear AC-1 10 A 440 V, AC-3 6 A 440 V, AC-15 4 A 440 V, DC-13 12 W 220 V
Locked rotor LR 36 A 240 V and 48 A 120 V on the product page
Bellows Phosphor bronze
Connector Brass
Fluid Gases and liquids
Enclosure IP30
Ambient -40 to 65 C
Net weight 0.305 kg
EAN 5702423147526

Applications of 060-316466

Small pressure-booster sets for buildings in Muscat, filtered-water skids, cooling circuits, and closed hydraulic loops with a low working pressure are all legitimate uses. The gold contacts make the switch suitable for a controller input that watches the low-pressure alarm of such a loop.

For a booster pump the contact must handle the motor starter coil, so check the type of load: with a gold set, an interposing relay is wise because a coil’s switching energy would soon burn the gold off.

How 060-316466 differs from other KPI variants

Parameter Value
060-121766 KPI 35, same range and differential, silver contacts
060-316466 KPI 35, gold-plated contacts
060-121966 KPI 35, silver contacts, differential 0.5 to 2.0 bar
060-118966 KPI 36, 4.0 to 12.0 bar, 0.5 to 1.6 bar differential
060-508166 KPI 38, 8.0 to 28.0 bar, 1.8 to 6.0 bar differential, 30 bar limit

Within the KPI 35 group, the choice is almost entirely about the contact metal and, for 060-121966, about the differential window.

Selection and installation of 060-316466

Specify the switch when the medium is clean water or similar fluid compatible with brass and phosphor bronze. Do not use it with aggressive liquids; for those, ask for a stainless version in the KP or KPI families. Mount it with the connector down, ensure the impulse line is bled, and use a 6 to 14 mm cable through the gland.

Insulation level is 400 V, pollution degree 3, and the circuit should be fused at 16 A or less.

Maintenance

Use the manual trip to prove wiring and check settings once a year with a calibrated gauge. If the pump cycles too often, widen the differential. Replace the switch if water seeps from the housing.

Ordering notes

Quote 060-316466 exactly. KPI 35 has silver and gold codes and IP55 transparent versions.

Contact and electrical data for 060-316466

Even though it is a gold-contact unit, the datasheet records the heavier ratings that apply after the gold layer has gone: AC-1 10 A at 440 V, AC-3 6 A at 440 V, AC-15 4 A at 440 V and DC-13 12 W at 220 V. The product page adds locked-rotor values of 36 A at 240 V and 48 A at 120 V, which shows that this series was also approved for small single-phase pump motors in the North American market.

The EN 60947 properties are an insulation level of 400 V, pollution degree 3, a 4 kV impulse rating and a recommended fuse of 16 A. Conductors of 0.75 to 2.5 mm2 solid or 0.5 to 1.5 mm2 flexible with ferrules fit the terminals, and the rubber gland takes cable between 6 and 14 mm.

Approvals shown on the product page include CE, CCC, EAC, RINA, CMIM and UL 873 with CSA C22.2, so the switch can be accepted by most shipping and industrial inspectors.

Commissioning example for 060-316466

Suppose a small booster set must maintain 3 bar at the highest tap. Set the range scale for 2.0 bar cut-in and the differential for 1.0 bar so that the pump stops at 3.0 bar. Run the pump, close the discharge slowly, and read the true cut-out pressure on a reference gauge; the scales are only a guide. Then trip the manual lever to make sure the pump starter and alarm circuits respond. Record the settings and fit the sealing screw if tampering is a concern.

Documents and quotation

The industrial KP and KPI datasheet accompanies this listing. Send an RFQ with the part number and quantity.

Delivery to Sites in Oman and the GCC

Delivery of the Danfoss 060-316466 is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive pressure switches equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Selection Notes for the Danfoss 060-316466

When comparing the Danfoss 060-316466 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Danfoss pressure switches range and confirm the correct order code before you commit.

Other Models in the Kpi Industrial Range

Seven Star LLC supplies models from the Kpi Industrial range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Danfoss 060-508166 KPI 38 Pressure Switch 8-28 barPressure SwitchesView details
Danfoss 060-118966 KPI 36 Pressure Switch 4-12 barPressure SwitchesView details
Danfoss 060-316466 KPI 35 Pressure Switch Gold ContactsPressure SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Danfoss 060-316466 KPI 35 Pressure Switch Gold Contacts Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 060-316466 KPI 35 Pressure Switch Gold

Answers from our engineering team on installation, compatibility and integration.

01What range does Danfoss 060-316466 cover?
A KPI 35 setting range of -0.2 to 8.0 bar with a differential of 0.4 to 1.5 bar.
02Can 060-316466 be used on liquids?
Yes, KPI switches are for liquid and gaseous fluids, and the product page lists water pumps and air compressors as applications.
03What is the pressure limit of 060-316466?
The permissible operating pressure is 18 bar and the maximum test pressure is also 18 bar.
04Why does 060-316466 have gold contacts?
Gold plating supports reliable closure of low-energy circuits, quoted at 1 to 30 mA and 5 to 30 V on the product page.
05Which material is the connector on 060-316466?
The datasheet lists a brass pressure connector and a phosphor bronze bellows for KPI 35 and KPI 36.