Hydac EDS 4448-0040-1-PP-000 is a compact programmable pressure switch for the lowest range of the EDS 4400 series, 0 to 40 bar. It has one PNP output, a G1/4 A male process port to ISO 1179-2 and a 5-pole M12x1 plug. The stainless steel cell uses a thin-film strain gauge on the membrane, so the switch point is electronic and not a spring setting. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Overview of EDS 4448-0040-1-PP-000

In day-to-day plant language the instrument is a pressure switch you program rather than adjust. Hydac designed the 4400 series so that one part number can replace many fixed-setting models, which is a real saving in stock when a site holds spares for several machines. Here the range of 40 bar suits lube-oil, air and low-pressure hydraulic circuits: the overload reserve is 80 bar, twice the range, and the burst limit is 200 bar.

Features of EDS 4448-0040-1-PP-000

  • Programmable switch point, hysteresis, N/O or N/C direction and delay times.
  • Switch-point step 0.1 bar, the finest of the 4448 ranges.
  • PNP output up to 1.2 A, more than 100 million cycles.
  • Supply 8 to 32 V DC, protected against reversed polarity and short circuit.
  • IP 67 with a mating connector fitted.
  • Settings protected: a stored configuration survives disconnection of the programmer.

Technical specifications for EDS 4448-0040-1-PP-000

Parameter Value
Model code EDS 4448-0040-1-PP-000
Material number (catalog) 920089
Setting range 0 to 40 bar
Overload pressure 80 bar
Burst pressure 200 bar
Process connection G1/4 A ISO 1179-2, male
Tightening torque 20 N·m recommended
Wetted parts Stainless steel connection; FKM seal
Switching output 1 PNP transistor output, programmable, N/O or N/C
Switching current 1.2 A maximum with one output
Switch-point increment 0.1 bar
Switch point / hysteresis window 5 to 100 percent / 1 to 96 percent of range
Delay times 8 to 2000 ms in 8 ms steps (HPG 3000)
Response time 8 ms
Accuracy 1 percent FS maximum; 0.5 percent typical
Temperature coefficient 0.02 percent FS per degC typical, 0.03 maximum
Repeatability 0.1 percent FS maximum
Long-term drift 0.3 percent FS per year typical
Electrical connection M12x1 male, 5-pole
Pins 1 +UB, 2 not connected, 3 0 V, 4 output 1, 5 not connected
Supply voltage 8 to 32 V DC, ripple 5 percent or less
Current consumption 25 mA inactive; 2.025 A total maximum
Switching cycles more than 100 million
Compensated temperature -25 to 85 degC
Storage temperature -40 to 100 degC
Protection class IP 67
Vibration / shock 20 g (10 to 500 Hz) / 100 g (1 ms)
Weight about 145 g
Approvals / EMC CE (EN 61000-6-1/2/3/4); cULus E318391

Applications in Oman and the GCC

The 40 bar span covers compressed air stations, lube-oil consoles of pumps and compressors, filter differential supervision and hydraulic accumulators at the low end. In desalination plants and power stations the output feeds a PLC input as a pump-run permissive or as a low-pressure trip. EDS 4448-0040-1-PP-000 is not a hazardous-area device; for classified zones use the flameproof or intrinsically safe EDS 4400 versions.

How EDS 4448-0040-1-PP-000 differs from other EDS 4448 ranges

Against EDS 4448-0100-1-PP-000 the range grows from 40 to 100 bar, overload from 80 to 200 bar, burst from 200 to 500 bar and the step from 0.1 to 0.2 bar. Against 0250 the numbers are 250 bar range, 500 bar overload, 1000 bar burst and a 0.5 bar step; against 0400 they are 400, 800, 2000 and 1 bar. All use the same housing, G1/4 port, 20 N·m torque, M12 plug and 8 ms response time.

Selection and compatibility

Choose the lowest range that covers peak pressure with margin. If the line spikes above 80 bar, choose 0100 instead. For liquids that attack FKM seals, discuss the seal with us before ordering EDS 4448-0040-1-PP-000. Programming needs the separate HPG 3000 and the 5-pin M12 mating connector is not part of the switch.

Installation and commissioning

Screw the G1/4 A thread into a port with a profile seal ring to DIN 3869, tighten to 20 N·m on the 27 mm hex and plug in the 5-pole M12 connector. Supply 8 to 32 V DC. Connect the programming unit, set the switch point inside 5 to 100 percent of range and the switch-back point inside 1 to 96 percent, choose N/O or N/C and enter delay times between 8 and 2000 ms. Verify with a hand pump before releasing EDS 4448-0040-1-PP-000.

Maintenance

There are no adjustment screws to wear. Inspect the O-ring or profile seal when the switch is removed, confirm the stored set points once a year and replace the unit if the accuracy of 1 percent of full scale is no longer met.

Typical Questions From Maintenance Teams

Maintenance engineers replacing a Hydac EDS 4448-0040-1-PP-000 usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed pressure switches, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.

Frequently asked questions about EDS 4448-0040-1-PP-000

What does the 0040 in EDS 4448-0040-1-PP-000 stand for? It is the measuring range in bar, 0 to 40 bar, which is the lowest range of the EDS 4400 series. Overload is 80 bar and burst is 200 bar.

Can I change the switch point on site? Yes, with the HYDAC HPG 3000 programming unit (listed in the datasheet as part number 909422). Set points, hysteresis, direction and delays are stored after the programmer is removed.

What does PP mean in the order code? The first P means a programmable switching output and the second P means PNP technology; NPN would be PN.

What is the smallest step for the switch point? 0.1 bar at this range, according to the catalog record.

How do I get a quotation for EDS 4448-0040-1-PP-000? Send an RFQ stating the part number, quantity and delivery location.

Documents and quotation

The datasheet for EDS 4448-0040-1-PP-000 is attached. Please send an RFQ with EDS 4448-0040-1-PP-000, the quantity and the delivery location for availability and lead time.

Other Models in the EDS 4400 Range

Seven Star LLC supplies models from the EDS 4400 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hydac EDS 4448-0250-1-PP-000 Programmable Pressure Switch 250 barPressure SwitchesView details
Hydac EDS 4448-0100-1-PP-000 Electronic Pressure Switch 100 barPressure SwitchesView details
Hydac EDS 4448-0040-1-PP-000 Programmable Pressure Switch 40 barPressure SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Hydac EDS 4448-0040-1-PP-000 Programmable Pressure Switch 40 bar Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac EDS 4448-0040-1-PP-000 Programmable Pressure

Answers from our engineering team on installation, compatibility and integration.

01What does the 0040 in EDS 4448-0040-1-PP-000 stand for?
It is the measuring range in bar, 0 to 40 bar, which is the lowest range of the EDS 4400 series. Overload is 80 bar and burst is 200 bar.
02Can I change the switch point on site?
Yes, with the HYDAC HPG 3000 programming unit (listed in the datasheet as part number 909422). Set points, hysteresis, direction and delays are stored after the programmer is removed.
03What does PP mean in the order code?
The first P means a programmable switching output and the second P means PNP technology; NPN would be PN.
04What is the smallest step for the switch point?
0.1 bar at this range, according to the catalog record.
05How do I get a quotation for EDS 4448-0040-1-PP-000?
Send an RFQ stating the part number, quantity and delivery location.