Brand:

Danfoss 060-450166 KP 36 Stainless Pressure Switch IP55

Description

Danfoss 060-450166: stainless steel KP 36 in an IP55 housing

Plain KP switches are built for clean gas, but not every plant has clean gas. Danfoss 060-450166 is the KP 36 version prepared for tougher surroundings: the Danfoss store page states stainless steel bellows and a stainless steel pressure connector, and the datasheet footnote describes it as a stainless steel version in a non-transparent IP55 enclosure. It keeps the familiar 2.0 to 14.0 bar range and the 0.7 to 4.0 bar differential of the standard KP 36.

Because it is intended for service where moisture, washdown or corrosive atmospheres are a concern, this code is a reasonable candidate for coastal sites in Oman, desalination and water-treatment plants, and food or beverage lines. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Why the enclosure and wetted parts matter

A standard KP 36 is an open IP30 unit and relies on the panel around it. This one carries its own IP55 housing, so dust and low-pressure water jets are kept out, and the cable enters through a metal Pg 13.5 screwed gland (DIN 40430) instead of a rubber grommet. Both choices make the device more suitable for mounting on a pipe rack or a pump skid outdoors.

Stainless steel in the wetted path widens the range of acceptable gases. The datasheet also notes special stainless models for demineralized water applications, where bronze and brass should be avoided.

Technical data of 060-450166

Parameter Value
Code number 060-450166
Type KP 36, stainless steel version
Setting range 2.0 to 14.0 bar
Differential 0.7 to 4.0 bar
Operating pressure 17 bar
Test pressure 22 bar
Pressure connection G 1/4 A, stainless steel
Bellows Stainless steel
Contacts SPDT silver, AC-1 16 A 400 V, AC-3 16 A 400 V, AC-15 10 A 400 V, DC-13 12 W 220 V
Enclosure IP55, non-transparent
Cable entry Metal gland Pg 13.5, DIN 40430
Net weight 0.439 kg
Gross weight 0.459 kg
Ambient -40 to 65 C, to 80 C for 2 h
Approvals CE, UL, CCC, EAC, RINA, CMIM
EAN 5702423279739

Uses for 060-450166 in industry

Think of pressurised air receivers that sit outside, cooling-water pressure checks next to a seawater-cooled heat exchanger, gas-reducing stations or aeration blowers in sewage treatment. In each case the combination of stainless parts and a closed enclosure keeps salt-laden air and splashes away from the mechanism.

On an offshore platform or a coastal refinery, a stainless unit also reduces the amount of corrosion product that can block the small pressure port.

How 060-450166 differs from standard KP 36 variants

Parameter Value
060-110866 KP 36 2.0 to 14.0 bar, silver contacts, open IP30, standard materials, 0.3 kg
060-113766 KP 36 2.0 to 14.0 bar, gold contacts, IP30
060-538766 KP 36 2.0 to 14.0 bar, silver contacts, IP55 transparent enclosure
060-450166 KP 36 2.0 to 14.0 bar, silver contacts, stainless wetted parts, IP55 non-transparent, 0.439 kg

The pressure data do not change; what changes is the mass (0.139 kg more than the 0.3 kg standard unit), the enclosure and the metal of the parts touching the gas.

Selecting 060-450166

Confirm that the gas is compatible with stainless steel and that pressure will not exceed 17 bar. If liquids are involved, a KPI unit is the better route. If you need to see the scale without opening the housing, ask about the transparent IP55 version, which has a different code.

Note also the temperature limits: the switch tolerates ambient temperature from -40 to 65 C and media up to 100 C, so it is not an answer to hot steam.

Installing and commissioning 060-450166

Mount it on a flat support using the base holes or a wall bracket, and orient the connector downward. Seal the pressure joint with a suitable washer rather than tape, since the connection is a parallel G 1/4 A thread. Tighten the Pg 13.5 gland on the cable to retain IP55, and fit a cable with a diameter that matches the gland.

Open the housing, set the range scale to the cut-in or cut-out, set the DIFF scale, close it and then verify with a gauge. The housing, being opaque, hides the scale, so record the setting.

Maintenance

Check the gland and the cover gasket at every plant inspection, because the IP55 rating depends on them. Operate the manual trip function to test the electrical circuit. The unit itself is not repairable.

Ordering

Use the full code 060-450166 when ordering. If a transparent cover is wanted, it is a different code number.

Electrical and environmental envelope of 060-450166

The contact block is the same single-pole double-throw design as other silver KP switches: AC-1 16 A at 400 V, AC-3 16 A at 400 V, AC-15 10 A at 400 V and DC-13 12 W at 220 V. The locked-rotor figure on the product page is 112 A at 400 V, so a direct-on-line starter coil or a small motor can be handled, although a contactor is the normal choice for any real motor.

Insulation to EN 60947 is rated 400 V with pollution degree 3 and an impulse withstand of 4 kV. Terminal capacity is 0.75 to 2.5 mm2 for solid or stranded wire and 0.5 to 1.5 mm2 for flexible wire with ferrules, and the recommended short-circuit fuse is 16 A.

The ambient limits are -40 to 65 C with excursions up to 80 C for two hours. Where the enclosure sits in direct sun in an Omani summer, a sunshade is a better answer than relying on that two-hour allowance.

Practical advice for stainless KP installations

Use a stainless fitting or a compatible adaptor between the process pipe and the G 1/4 A connector to avoid galvanic pairing with brass. Fit a short siphon or a needle valve if the process pulsates, because stainless bellows are stiffer and benefit from a damped signal. Write the chosen set points on the housing label, since the opaque cover hides the scales once closed.

Documents and quotation

The datasheet covering this stainless version is attached. Email an RFQ stating the part number and quantity.

Other Models in the Kp Industrial Range

Seven Star LLC supplies models from the Kp Industrial range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Danfoss 060-122166 KP 36 Pressure Switch 4-12 barPressure SwitchesView details
Danfoss 060-450166 KP 36 Stainless Pressure Switch IP55Pressure SwitchesYou are viewing this model
Danfoss 060-114466 KP 36 Pressure Switch Gold ContactPressure SwitchesView details
Datasheets & Documents
  • PDF Datasheet Danfoss 060-450166 KP 36 Stainless Pressure Switch IP55 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 060-450166 KP 36 Stainless Pressure Switch

Answers from our engineering team on installation, compatibility and integration.

01Is 060-450166 made of stainless steel?
According to the product page it has a stainless steel bellows and a stainless steel connector, and the datasheet describes it as the stainless version in an IP55 non-transparent housing.
02What pressure range does 060-450166 have?
2.0 to 14.0 bar setting range with a 0.7 to 4.0 bar differential, and a permissible operating pressure of 17 bar.
03What cable entry does 060-450166 use?
A metal Pg 13.5 screwed cable gland to DIN 40430, not the rubber gland of the IP30 versions.
04How heavy is 060-450166?
The net weight on the product page is 0.439 kg, compared with 0.3 kg for the open IP30 KP 36.
05Can 060-450166 be used on liquids?
The datasheet assigns gaseous media to KP 35 and KP 36; liquids call for a KPI model.