Brand:

AMETEK 7000-843-SE WDG-V Box Heater Assembly 120 VAC

Description

AMETEK 7000-843-SE overview

AMETEK 7000-843-SE is the box heater assembly, 120 VAC, for the Thermox WDG-V analyzer. The box heater keeps the analyzer sample enclosure above the sample dew point so that moisture and acid do not condense inside the sample path. The WDG-V datasheet allows a maximum sample dew point of 200 degrees C, so the heated box is central to reliable operation on wet flue gas. The 240 VAC version is listed separately as 7000-844-SE in the manual spare parts table.

The Thermox WDG-V is AMETEK Process Instruments’ close-coupled extractive analyzer for excess oxygen in flue gas. The datasheet describes a zirconium oxide sensor, measurement redundancy, continual diagnostic functions and SIL 2 capability for burner management systems, with flue gas temperatures up to 1648 degrees C (3000 degrees F) depending on the probe. It is completely field-serviceable, and the manual lists the spare parts by AMETEK part number.

Key features of 7000-843-SE

  • Box heater assembly for 120 VAC WDG-V analyzers
  • Keeps the sample enclosure warm for dew point protection
  • 240 VAC version is 7000-844-SE
  • Slides out after removing one speed clip
  • Only one heater in the O2 version, two in combustibles and methane versions
  • Wires connect on the sensor board

7000-843-SE technical specifications

Item Detail
Part number 7000-843-SE
Description Assembly, WDG-V box heater, 120 VAC
240 VAC equivalent 7000-844-SE
Max sample dew point (datasheet) 200 degrees C (392 degrees F)
Heater count One in O2 version, two in combustibles or methane version
Used in Thermox WDG-V, WDG-VC, WDG-VCM analyzers
Principle (datasheet) Zirconium oxide for excess oxygen
Output range 0-1 percent to 0-100 percent O2
Accuracy Plus or minus 0.75 percent of measured value or plus or minus 0.05 percent, whichever is greater
Response 90 percent of a step change in under 11 seconds with flame arrestors
Aspirator air About 3 SCFH at 3 to 6 psig, instrument air or nitrogen
Outputs Three isolated linear current outputs, five alarms, Modbus RTU, HART option
Enclosure Hinged IP65 (NEMA 4X) stainless steel
Power 115 VAC or 230 VAC, plus or minus 10 percent, 740 VA maximum

Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 7000-843-SE. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.

Typical applications in oil and gas, utilities, water and manufacturing

Process heaters, steam boilers and thermal oxidizers are the applications named in the datasheet, and the key markets are refining and petrochemical, power and steam generation, and furnaces and boilers. In Oman and across the GCC those applications correspond to refinery heaters, gas processing furnaces, utility boilers and thermal oxidizers on petrochemical and fertilizer sites, where excess oxygen is the primary indicator for burner efficiency and safe combustion.

Where 7000-843-SE is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 7000-843-SE

Confirm the analyzer version (O2 only, combustibles, or combustibles and methane), the supply voltage of the unit and, if possible, the AMETEK serial number before ordering. The WDG-V manual spare parts table is the reference that ties each number to a version.

Part number 7000-843-SE is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

The manual procedure: disconnect the heater wires, remove the speed clip from the mounting tab using needle-nose pliers, and slide the box heater out. Fit 7000-843-SE, attach a new speed nut to the post and reconnect the wires on the sensor board. The manual notes that the O2 version has only one heater while the combustibles and methane version has two, so confirm the position of the heater you are replacing before disconnecting wires.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 7000-843-SE. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

A box heater fault shows as a box temperature alarm. The manual troubleshooting section tells the technician to check the box temperature RTD and the box heater, and part numbers for both the RTD and cartridge heater kits are in the spare parts list.

Related products and ordering notes

Review the cartridge heater kits 7000-846-TE and 7000-849-TE, heater plate 7000-405-KE and RTD 25384JE (O2 only) or 1000-630-JE (combustibles or methane).

For a spare parts plan, list 7000-843-SE against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Process plants in Oman and the wider GCC run long between shutdowns, which is why maintenance planners check part numbers early and hold critical spares. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We source against the exact number you give us and confirm availability and lead time before you commit.

Frequently asked questions about 7000-843-SE

  • What is AMETEK 7000-843-SE? It is the box heater assembly for the 120 VAC version of the Thermox WDG-V analyzer.
  • Which number is the 240 VAC box heater? The manual spare parts table lists 7000-844-SE for the 240 VAC box heater assembly.
  • How many box heaters does a WDG-V have? The manual says there is one heater in the O2 version and two heaters in the combustibles and methane version.

Documents and quotation

The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 7000-843-SE, send the RFQ with the part number 7000-843-SE, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Datasheets & Documents
  • PDF Datasheet AMETEK WDG-V Flue Gas Oxygen Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 7000-843-SE WDG-V Box Heater Assembly 120 VAC

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 7000-843-SE?
It is the box heater assembly for the 120 VAC version of the Thermox WDG-V analyzer.
02Which number is the 240 VAC box heater?
The manual spare parts table lists 7000-844-SE for the 240 VAC box heater assembly.
03How many box heaters does a WDG-V have?
The manual says there is one heater in the O2 version and two heaters in the combustibles and methane version.
04What is the maximum dew point the WDG-V handles?
The datasheet gives a maximum sample dew point of 200 degrees C (392 degrees F).
05How do I request a quotation for 7000-843-SE?
Send the part number 7000-843-SE, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.