- Automation & ControlView all 2,894 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ABB
ABB ACH580-01-03A4-4 1.1 kW HVACR Drive
Description
ABB ACH580-01-03A4-4 HVACR drive for 1.1 kW motors
The ABB ACH580-01-03A4-4 is a wall-mounted variable frequency drive from the ACH580 series, which ABB built specifically for heating, ventilation, air conditioning and refrigeration (HVACR). It belongs to frame size R1, runs on a 3-phase 380 to 480 V supply and has a nominal output current of 3.3 A for a typical motor power of 1.1 kW. At 1.1 kW and 3.3 A this is one of the smallest HVACR drives of the ACH580-01 range. It is aimed at small fan coil and ventilation fans, small circulating pumps and similar loads in commercial buildings where a dedicated building-automation drive is wanted instead of a general-purpose unit.
This page explains how the ACH580-01-03A4-4 is specified, what its application software does and which installation data matters, so that you can prepare a precise enquiry. The figures come from the ABB ACH580 HVACR catalog.
Decoding the ACH580-01-03A4-4 type designation
The ACH580 type code follows the same structure as other ABB all-compatible drives.
| Field | Value in ACH580-01-03A4-4 | Meaning |
|---|---|---|
| Product series | ACH580 | HVACR drive with application software for fans, pumps and compressors |
| Type and construction | 01 | Standard six-pulse drive, wall-mounted construction |
| Rating | 03A4 | Current class label used in the ordering code; nominal current in the ratings table is 3.3 A |
| Voltage | 4 | 3-phase 400 V class (380 to 480 V) |
| Options | + codes | For example +B056 for IP55, +F278 for a main disconnect switch, +J400 for the Hand-Off-Auto panel |
ACH580-01-03A4-4 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ABB / ACH580-01-03A4-4 |
| Product family | ACH580-01 wall-mounted HVACR drive, frame R1 |
| Supply voltage | 3-phase 380 to 480 V (+10 % / −15 %), 48 to 63 Hz |
| Nominal output current / power at 400 V | 3.3 A / 1.1 kW |
| Nominal output current / power at 480 V | 3 A / 1.5 hp |
| Output frequency | 0 to 598 Hz |
| Motor control | Scalar and vector control; induction, PM, SynRM and PM-assisted SynRM motors |
| Heat loss, cooling air, noise | 51 W typical; 43 m³/h (25 ft³/min); 59 dBA at full fan speed |
| Recommended input fuse | 6 A gG (IEC); 15 A Class T (UL) |
| Degree of protection | IP21 (UL Type 1) or IP55 (UL Type 12) |
| Ambient temperature | –15 to +50 °C, with derating from +40 °C; no frost allowed |
| Altitude | Full current 0 to 1000 m; reduced by 1 % per 100 m above 1000 m, up to 4000 m |
| EMC and efficiency | EMC category C2 as standard (C1 as option up to 55 kW); efficiency class IE2 |
| Communication | BACnet MS/TP, Modbus RTU and N2 embedded (EIA-485); options include BACnet/IP and Modbus TCP |
| Control I/O (standard) | 2 analog inputs, 2 analog outputs, 6 digital inputs, 3 relay outputs, 24 V DC output up to 250 mA |
| Functional safety | Safe Torque Off, SIL 3 / PL e |
What makes the ACH580-01-03A4-4 an HVACR drive
Compared with a general purpose drive, the difference is in the firmware. Fans benefit from fireman’s override, flying start, air filter monitoring and resonance skipping. Pumps get intelligent pump control for up to eight parallel units, dry-run protection, overpressure protection and a sleep/boost mode that stops the pump at low demand. Soft ramps for starting and stopping reduce mechanical and electrical stress throughout the system.
Other built-in features include a real-time clock for scheduling, motor heating to prevent condensation on rooftop units, frost protection, bearing and leakage monitoring and a cooling compressor package with short-cycle protection and a refrigerant selection feature. For installations beside A2L and A3 refrigerant equipment, the ACH580-01 is listed as compliant with IEC/UL 60335-2-40:2022.
The R1 enclosure is 125 mm wide and weighs 4.6 kg, so it can be mounted close to the motor or on a small panel, and the recommended 6 A gG input fuse keeps the feeder simple.
Where ACH580-01-03A4-4 fits in the ACH580 range
The ACH580-01 covers 0.75 to 355 kW on 380 to 480 V, with sibling products for other needs: ACH580-04 drive modules for cabinet builders, ACH580-07 cabinet-built drives, and the ultra-low harmonic ACH580-31 and ACH580-34 versions. In the 400 V wall-mounted list the ACH580-01-03A4-4 sits between ACH580-01-02A7-4 and ACH580-01-04A1-4. For machinery, pumps and conveyors outside building services, the ACS580 general purpose family is the closer match, because it shares hardware but not the HVACR application macros.
Frame R1 ratings related to ACH580-01-03A4-4
| Type designation | Frame | Nominal power (kW) | Nominal current at 400 V (A) | Current at 480 V (A) | Power at 480 V (hp) |
|---|---|---|---|---|---|
| ACH580-01-02A7-4 | R1 | 0.75 | 2.6 | 2.1 | 1 |
| ACH580-01-03A4-4 | R1 | 1.1 | 3.3 | 3 | 1.5 |
| ACH580-01-04A1-4 | R1 | 1.5 | 4 | 3.5 | 2 |
| ACH580-01-05A7-4 | R1 | 2.2 | 5.6 | 4.8 | 3 |
| ACH580-01-07A3-4 | R1 | 3 | 7.2 | 6 | 3 |
| ACH580-01-09A5-4 | R1 | 4 | 9.4 | 7.6 | 5 |
| ACH580-01-12A7-4 | R1 | 5.5 | 12.6 | 12 | 7.5 |
Selection and ordering checklist
- Confirm the application: the ACH580-01-03A4-4 carries HVACR macros for fans, pumps and compressors; for other machinery consider the ACS580.
- Match the motor current to the 3.3 A nominal output at 400 V (3 A at 480 V).
- Decide the enclosure: IP21 (UL Type 1) or IP55 (UL Type 12, code +B056). The IP55 version is designed for dust, moisture and vibration.
- For IP55 frames R1 to R5, an integrated main disconnect switch (+F278) and the combined switch with EMC C1 filter (+F316) are available.
- Choose the fieldbus: BACnet MS/TP, Modbus RTU and N2 are built in; BACnet/IP, Modbus TCP, PROFINET IO and EtherNet/IP are plug-in options.
- Select the control panel: the Hand-Off-Auto assistant panel (+J400) is included as standard and can be replaced by another +Jxxx option.
- Confirm plus codes and current class against the ABB ordering table before placing the order.
Installing and commissioning ACH580-01-03A4-4
Frame R1 measures 373 mm in height (with gland box), 125 mm in width and 223 mm in depth in the IP21 version and weighs 4.6 kg. The IP55 version is 403 mm high, 128 mm wide and 233 mm deep at 4.8 kg; with a disconnect switch or C1 filter the height is 403 mm and the weight 5.4 kg.
| Version | Height (mm) | Width (mm) | Depth (mm) | Weight (kg) |
|---|---|---|---|---|
| IP21 (UL Type 1) | 373 | 125 | 223 | 4.6 |
| IP55 (UL Type 12) | 403 | 128 | 233 | 4.8 |
Allow 43 m³/h of cooling air and 51 W of dissipated heat in the panel or plant-room design. The recommended input protection is 6 A gG or 15 A UL Class T. During commissioning, the first start assistant sets the primary HVACR parameters; the default I/O wires a damper output, a run output and a fault output on the three relays, with a start interlock input. Store the parameters in the panel afterwards, because a backup can be restored to another drive. Keep the nameplate type code on file when ordering spares.
Typical applications of ACH580-01-03A4-4 in Oman and the GCC
In Oman and the GCC small drives like this one are found in air-handling units on hotel and office roofs, in utility pump skids at desalination and water-treatment sites, and on conveyors and mixers in food, packaging and light-industrial plants. The ambient in a Muscat technical room or a rooftop plant box can run well above 40 °C in summer, so the derating rule matters: the catalog gives full current up to 40 °C and lets the drive operate up to the higher limit with derating. Fine dust and salty humid air are the other everyday stresses, which is why an IP55 version is often preferred for wall mounting outside a clean electrical room. Air-handling units, chillers, cooling towers, chilled and condenser water pumps are the natural fit for the ACH580 in hotels, hospitals, airports, malls and data centres, where cooling demand is high for most of the year and energy savings from speed control are significant.
Information to send with an RFQ
Please send the full type designation with plus codes, the supply voltage and frequency, the motor power and rated current, the application (AHU fan, chilled water pump, cooling tower, compressor), the ambient temperature, the required enclosure, the building automation protocol and any disconnect, filter or fieldbus option. A nameplate photograph of the drive being replaced helps confirm a match with the ACH580-01-03A4-4.
Documents and quotation
The ratings, cooling data, dimensions and options used in this description come from the ABB ACH580 HVACR catalog. Please verify the final selection of the ACH580-01-03A4-4 against the current ABB documentation for your project.
Seven Star LLC supplies ABB drives in Oman and the GCC. Send the part number and your duty details and we will confirm the available documents and return a quotation with delivery information.
Other Models in the Abb Ach580 01 Wall Range
Seven Star LLC supplies models from the Abb Ach580 01 Wall range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB ACH580-01-03A4-4 1.1 kW HVACR Drive | AC Drives | You are viewing this model |
| ABB ACH580-01-07A3-4 3 kW HVACR Drive | AC Drives | View details |
| ABB ACH580-01-089A-4 45 kW HVACR Drive | AC Drives | View details |
| ABB ACH580-01-246A-4 132 kW HVACR Drive | AC Drives | View details |
Datasheets & Documents
- Brochure ABB ACH580 HVACR Drive Flyer Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB ACH580-01-03A4-4 1.1 kW HVACR Drive
Answers from our engineering team on installation, compatibility and integration.
01What protocols does ACH580-01-03A4-4 speak out of the box?
The embedded EIA-485 port supports BACnet MS/TP, Modbus RTU and N2 as standard. Plug-in options add BACnet/IP, Modbus TCP, PROFINET IO, EtherNet/IP and several other fieldbuses, so the same hardware suits most building automation systems.
02Is ACH580-01-03A4-4 an HVACR-specific drive?
Yes. The ACH580 series is dedicated to HVACR duties, with functions such as fireman’s override, air filter monitoring, intelligent pump control, motor preheating, frost protection and a cooling compressor package built into the software.
03Which building automation protocols does ACH580-01-03A4-4 support?
BACnet MS/TP, Modbus RTU and N2 are embedded as standard on the EIA-485 port. Optional plug-in adapters add BACnet/IP, Modbus TCP, PROFINET IO, EtherNet/IP and other networks.
04What enclosure ratings are available for ACH580-01-03A4-4?
The standard drive is IP21 (UL Type 1). An IP55 (UL Type 12) version is available with the +B056 code for dusty or humid environments, and frames R1 to R5 can add a main disconnect switch.
05What are the cooling and fuse requirements of ACH580-01-03A4-4?
The catalog gives 43 m³/h of cooling air, 51 W of typical heat loss, a maximum noise level of 59 dBA, and recommended input fuses of 6 A gG or 15 A UL Class T.