Brand: Lovato Electric
Lovato DMED100T1 Single-Phase Energy Meter 40 A Direct
Description
Lovato DMED100T1 single-phase energy meter, 40 A direct
The Lovato DMED100T1 is a single-phase kilowatt-hour meter in a one-module DIN-rail housing with direct connection up to 40 A. It measures active energy to accuracy class 1 and provides a pulse output for remote counting. Seven Star LLC supplies the DMED100T1 in Oman and the GCC as an independent supplier in Muscat.
The part number is the catalogue designation itself: DMED is the energy meter family, and the catalogue lists this variant as a single-phase direct-connection meter. The meter is used for sub-metering a tenant, a machine or a circuit, where the three-phase DMED301 or the DMED300T2 would be too much.
DMED100T1 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Lovato / DMED100T1 |
| Type | Single-phase, 1 DIN module |
| Rated voltage (phase-neutral) | 220 to 240 V AC; operating range 184 to 264 V |
| Connection | Direct |
| Current Imax / Iref / Imin | 40 A / 5 A / 0.25 A |
| Starting current / transition current | 20 mA / 0.5 A |
| Accuracy | Class 1 active energy (IEC/EN 62053-21) |
| Frequency | 50/60 Hz; rated 50 Hz |
| Consumption | 7 VA maximum; 0.45 W |
| LED pulse | 1000 pulses/kWh, 30 ms |
| Static output | 10 pulses/kWh, 100 ms; 10 to 30 V DC; 50 mA |
| Insulation Ui / Uimp | 250 V / 6 kV |
| Terminals | 1.5 to 10 mm²; 1.5 Nm maximum |
| Temperature | -25 to +55 °C |
| Altitude and pollution | 2000 m; pollution degree 2; overvoltage category III |
| Weight and housing | 86 g; polyamide |
How the DMED100T1 measures and reports energy
The meter multiplies instantaneous voltage and current and integrates the result into kilowatt-hours. Class 1 accuracy applies between the transition current of 0.5 A and Imax of 40 A for the specified conditions, and the meter begins to count from a starting current of 20 mA, so small standby loads are not lost.
Two pulse signals are available. A front LED flashes at 1000 pulses per kWh so a technician can verify the meter against a reference load, and a static output gives 10 pulses per kWh for a PLC or energy gateway. The static output needs an external 10 to 30 V DC supply and can carry up to 50 mA.
DMED100T1 in a metering scheme
A common arrangement installs one DMED100T1 per tenant or machine, wires the static outputs to a pulse counter and reads totals in a monitoring system. Where a serial interface is needed on a three-phase circuit, the DMED301 offers RS485. For circuits above 40 A or for three-phase loads a different meter is needed, because this unit is limited to circuits up to 40 A.
DMED100T1 selection checklist
- Single-phase supply of 230 V nominal
- Load current below the 40 A maximum
- Class 1 accuracy suitable for sub-metering
- Pulse output needs and the supply for the output
- One-module space on the rail
- Environmental temperature up to 55 °C
- Whether a billing-grade certified meter is required, which should be confirmed separately
Installing the DMED100T1
Install on a 35 mm rail, connect the load through the fixed terminals and keep the incoming conductor sized for the circuit protection. Tighten to the specified torque. Mount upstream a miniature circuit breaker rated for the cable, since the meter itself has no protective function.
Verify the first readings by comparing the displayed energy with a known load over a short test, and record the opening meter reading for later billing or reporting.
Typical DMED100T1 applications in Oman and the GCC
Typical uses include tenant sub-metering in offices and labour camps, monitoring of air-conditioning circuits, which dominate energy use in the region, and allocation of costs to machines in workshops. Switch-room temperatures remain inside the -25 to +55 °C limit if the board is ventilated.
DMED meters side by side
| Part | Type | Maximum current | Interface |
|---|---|---|---|
| DMED100T1 | Single-phase | 40 A direct | LED and static pulse outputs |
| DMED301 | Three-phase plus neutral | 80 A direct | RS485 |
| DMED300T2 | Three-phase | Listed separately | See data sheet |
| DMED330 | Three-phase | Listed separately | See data sheet |
For tenant billing, check whether the local utility or landlord requires a meter with a specific certification or sealing. The catalogue data describe accuracy class 1 under IEC standard 62053-21 but do not make this meter a legal billing device on their own, so confirm the requirement before ordering. For internal cost allocation and energy awareness, class 1 is more than adequate. Label each meter with the area it serves and keep a record of the opening reading, the date and the serial number, which makes later disputes and audits much easier to settle.
Reading the numbers correctly also helps. Imin, 0.25 A, is the lowest current at which the stated accuracy is guaranteed, Iref (5 A) is the reference level, and Imax (40 A) is the highest continuous current. A circuit that spends most of its time below 0.5 A, such as a lightly loaded lighting circuit, can show larger percentage errors than a circuit running at 10 to 30 A. In such a case compare the total over a month against an upstream reference before drawing conclusions. The meter withstands 4 kV at power frequency and 6 kV impulse, which gives good margin against switching transients on the supply.
Information to send with an RFQ for the DMED100T1
- Part number DMED100T1 and quantity
- Supply voltage and circuit current
- Pulse output wiring needs
- Certification requirements for billing
- Delivery location
- Project reference
Site conditions in Oman for the DMED100T1
Electrical rooms and outdoor panels in the Gulf often operate well above the 25 °C reference temperature used in many catalogues. Before you finalise the DMED100T1, compare the expected panel temperature with the operating range and any output derating stated in the manufacturer documentation, and leave the recommended clearance above and below the device for convection. Supply quality also varies between sites, so confirm the input voltage range, frequency and any requirements for protection on the supply side.
Where the device feeds or monitors critical loads, plan how faults will be signalled to the control system and how a replacement can be installed quickly. Keeping one spare DMED100T1 per site and recording its settings helps maintenance teams in Oman restore service with minimum downtime.
Documents and quotation
Send the part number DMED100T1 and we will confirm the documents available for it, such as the technical data sheet, wiring diagram and instruction sheet, together with availability and lead time.
Seven Star LLC is an independent supplier in Muscat and is not an official channel of the manufacturer. Share the quantity, delivery location and project reference with the request and we will answer with a formal quotation.
Other Models in the Lovato Dmed Meter Range
Seven Star LLC supplies models from the Lovato Dmed Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Lovato DMED111 Single-Phase Energy Meter 40 A RS485 | Power Meters & Power Quality | View details |
| Lovato DMED100T1 Single-Phase Energy Meter 40 A Direct | Power Meters & Power Quality | You are viewing this model |
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
FAQ
Questions about the Lovato DMED100T1 Single-Phase Energy Meter 40 A
Answers from our engineering team on installation, compatibility and integration.
01What current can the DMED100T1 measure directly?
Up to 40 A maximum, with a reference current of 5 A and a minimum current of 0.25 A.
02What accuracy class does it have?
Class 1 for active energy according to IEC/EN 62053-21.
03How wide is it?
The housing is one DIN module wide and weighs 86 g.
04What pulse outputs does it have?
An LED at 1000 pulses per kWh and a static output at 10 pulses per kWh.
05What voltage does it measure?
It is for a 220 to 240 V phase-neutral supply with an operating range of 184 to 264 V.