Brand: Janitza
Janitza UMG 512-PRO Class A Power Quality Analyser
Description
UMG 512-PRO Class A power quality analyser for 50/60 Hz networks
The Janitza UMG 512-PRO is a panel-mounted power quality analyser and energy meter built for permanent monitoring of low, medium and high voltage networks through current and voltage transformers. It records the full set of Class A power quality parameters defined in IEC 61000-4-30, offers both Modbus and Profibus connectivity, and adds residual current and temperature inputs. Seven Star LLC supplies the UMG 512-PRO in Oman and the GCC as an independent supplier in Muscat.
The datasheet lists two supply versions: a 230 V option (95 to 240 V AC or 80 to 300 V DC) and a 24 V option (48 to 110 V AC or 24 to 150 V DC). Confirm which one your site needs before ordering, because the supply range is fixed by the variant.
UMG 512-PRO technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Janitza / UMG 512-PRO |
| Supply, 230 V option | 95 to 240 V AC (50/60 Hz) or 80 to 300 V DC; max. 7 W / 14 VA |
| Supply, 24 V option | 48 to 110 V AC (50/60 Hz) or 24 to 150 V DC; max. 9 W / 13 VA |
| Voltage measurement | L-N 10 to 600 Vrms, L-L 18 to 1000 Vrms; 4 MΩ per phase; 600 V CAT III |
| Current measurement | Nominal 5 A, range 0.005 to 7 Arms, for ../5 A transformers; sampling 25.6 kHz per phase |
| Accuracy (50/60 Hz) | Voltage and current 0.1; active power and energy 0.2 / 0.2S with ../5 A transformer; frequency 0.02 (IEC 61557-12) |
| Standards for power quality | IEC 61000-4-30 Class A; flicker per IEC 61000-4-15; harmonics per IEC 61000-4-7 Class 1 |
| Harmonics | Up to the 50th harmonic, maximum 3 kHz |
| Transients | 39 µs |
| Residual current inputs (RCM) | Two inputs, 0 to 40 mArms, 100 µA response, type A per IEC/TR 60755 |
| Temperature input | PT100, PT1000, KTY83, KTY84; three-wire |
| Digital I/O | 2 digital inputs (18 to 28 V DC) and 2 optocoupler digital outputs (max. 60 V DC, 50 mA) |
| Interfaces | RS485 (Modbus RTU slave, master, gateway; up to 921.6 kbps), Profibus DP/V0 (SUB-D 9, up to 12 MBaud), Ethernet RJ45 (Modbus TCP gateway, web server, SNMP, NTP, FTP, SMTP; BACnet optional) |
| Operating temperature | -10 to +55°C; 5 to 95% RH non-condensing; altitude up to 2000 m |
| Protection | IP40 front, IP20 rear; for weather-protected fixed installation |
| Dimensions / weight | About 144 x 144 x 75 mm; about 1080 g with connectors; cut-out 138 x 138 mm |
How the UMG 512-PRO measures and records
The analyser samples every voltage and current channel at 25.6 kHz and evaluates the waveform continuously without gaps. From these samples it derives rms values, power, energy, frequency, harmonics, flicker, unbalance, dips, swells, short interruptions and transients. Events are timestamped and stored, so a trip, a voltage sag or a harmonic problem can be matched with the process event that caused it.
Besides the three phase channels, the UMG 512-PRO has an additional current input, so the neutral conductor can be measured directly rather than calculated. The residual current inputs let the same device watch earth-leakage trends, and the temperature input can supervise a transformer or busbar sensor. The Jasic programmable logic in the device can combine these inputs with the digital outputs for simple local alarming.
Where the UMG 512-PRO fits in a power system
Use it at the incomer of a main switchboard, on a generator or transformer feeder, or at the point of common coupling where compliance with grid power quality limits is checked. Data is read over Modbus RTU, Modbus TCP or Profibus into a SCADA, DCS or energy management system. The simpler UMG 512 on the same platform lacks the Pro-level data set, and the manufacturer offers other devices in the UMG range for sub-metering where Class A is not required.
Selecting and ordering the UMG 512-PRO
- Choose the correct auxiliary supply version: 230 V or 24 V option.
- Confirm the secondary current of the CTs; accuracy classes in the datasheet assume ../5 A, and ../1 A transformers give class 0.5/0.5S.
- Check the network voltage against the 600 V L-N and 1000 V L-L input limits; higher voltages need voltage transformers.
- Choose the fieldbus: RS485 Modbus, Profibus or Ethernet, and whether the BACnet option is wanted.
- Confirm panel cut-out of 138 x 138 mm and that the rear terminals (IP20) are protected inside the cabinet.
- Check whether residual current monitoring or temperature sensing will be used.
Installation, commissioning and maintenance of the UMG 512-PRO
The device must be mounted vertically in a weather-protected, fixed installation and connected to protective earth. The supply needs a 6 A type B fuse, and the voltage measuring inputs must be fused with 1 to 10 A. Current inputs must not be left open when a CT is loaded; short the CT secondary before working on the terminals. Terminal torque is 0.4 to 0.5 N·m for supply, voltage and current, and 0.2 to 0.25 N·m for the signal terminals.
After wiring, set the CT and VT ratios, the network type and communication settings, then compare the displayed phase values and power sign with a reference instrument. A lithium CR2450 battery backs the real-time clock, so plan to replace it at maintenance intervals, and keep a recent copy of the device configuration for spares swap-over.
Typical applications in Oman and the GCC
Gulf power systems combine heavy motor loads, variable speed drives and large compressors, all of which distort voltage and current. The UMG 512-PRO suits main substations of refineries, petrochemical plants, desalination sites and gas processing facilities, as well as data centres and commercial towers where energy cost and power quality both matter. Installed in air-conditioned switchrooms, it fits the -10 to +55°C operating range; outdoor kiosks in Oman summers should be checked for heat load and dust.
Information to send with a UMG 512-PRO RFQ
- Quantity and required supply voltage option (230 V or 24 V).
- Network voltage, CT ratio and secondary current.
- Fieldbus or SCADA protocol required, including any BACnet need.
- Whether temperature, residual current or digital I/O will be used.
- Panel space and delivery destination in Oman or the GCC.
Related Janitza products: Janitza UMG 604-PRO Power Quality Analyser, Janitza UMG 96RM Panel Power Analyser RS485 Modbus and Janitza UMG 508 Universal Measuring Device.
Documents and quotation
Send us the part number UMG 512-PRO together with the supply option and your quantity, and we will confirm the documents that are available for it.
Seven Star LLC will then prepare a quotation and confirm lead time for delivery to Oman and the GCC.
Datasheets & Documents
- datasheet Janitza UMG 512-PRO Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Janitza is a German family-owned maker of energy and power quality measuring devices, based in Lahnau, Hesse. Janitza electronics was founded in 1986 as a subsidiary of Eugen Janitza GmbH, which dates from 1961, and is led by owner Markus Janitza. It makes power analysers, power quality monitors, energy management software and reactive power controllers.
Seven Star LLC lists the Janitza UMG 508 and supplies Janitza power quality analyzers and their accessories to plants and building operators in Oman and the GCC.
Janitza company profile
| Founded | 1986, Lahnau, Germany |
|---|---|
| Roots | Eugen Janitza GmbH, 1961 |
| Ownership | Family-owned, second generation |
| Applications | Energy monitoring, power quality, ISO 50001 |
| Product families | UMG 604-PRO and UMG 508 power analysers, UMG 96RM panel meters, GridVis software, reactive power controllers |
Milestones
- 1961: Eugen Janitza GmbH is founded.
- 1986: Janitza electronics is founded in Lahnau.
Janitza UMG 508 and the UMG series
The UMG 508 is a panel-mounted power analyzer with a color graphic display. It measures the electrical quantities of a three-phase system continuously, records harmonics up to the 40th order and supply events in its own memory, and passes data to energy management or SCADA software over Ethernet and RS485. Modbus and Profibus DP are among its protocols, and Janitza GridVis software is used to set it up and read it out.
Janitza products we list
| Family | Examples |
|---|---|
| Controllers & Data Acquisition | UMG 508 Universal Measuring Device, UMG 604-PRO Power Quality Analyser, UMG 96RM Panel Power Analyser RS485 Modbus |
Ordering Janitza devices: what we need
Give the Janitza item number or the full type from the rating label, since one UMG model can be made in more than one supply voltage version. Add the auxiliary voltage in the panel, the measured system voltage, current transformer secondary (1 A or 5 A), the protocol your software uses, and any current transformers or residual current sensors to be quoted with it.
Facts checked against Janitza company portraits and profiles, October 2026.
Browse Janitza products by category: Controllers & Data Acquisition.
FAQ
Questions about the Janitza UMG 512-PRO Class A Power Quality Analyser
Answers from our engineering team on installation, compatibility and integration.
01Which supply voltages are offered for the UMG 512-PRO?
The datasheet lists a 230 V option at 95 to 240 V AC or 80 to 300 V DC, and a 24 V option at 48 to 110 V AC or 24 to 150 V DC. The supply range depends on the version, so it must be specified when ordering.
02Does it comply with IEC 61000-4-30 Class A?
The manufacturer states that the device is a certified Class A power quality analyser per IEC 61000-4-30, with flicker per IEC 61000-4-15 and harmonics per IEC 61000-4-7 Class 1.
03What communication interfaces does it have?
It has RS485 (Modbus RTU slave, master or gateway), Profibus DP/V0 on a SUB-D 9 connector and an Ethernet RJ45 port with Modbus TCP gateway, web server, SNMP and NTP. BACnet is an option.
04What sensors can the temperature input read?
It supports PT100, PT1000, KTY83 and KTY84 sensors in a three-wire connection, with a maximum total burden of 4 kΩ including cable.
05Can it measure residual current?
Yes. There are two residual current inputs with a 0 to 40 mArms range, 100 µA response current and 1 µA resolution, measured per IEC/TR 60755 type A.