Metrel MI 2893 Power Master XT Class A Power Quality Analyser
Description
Class A power quality analysis with transient capture at 1 MS/s
The Metrel MI 2893 Power Master XT extends the Power Master line with high-speed transient capture. Metrel describes it as a hand-held three-phase power quality analyser that shows harmonics, phasors, waveforms and transients, with a sampling frequency of 1 MSamples per second, on a large colour display. It complies with IEC 61000-4-30 Class A and is used for both long-term recording and for finding power quality faults in three-phase and single-phase systems.
The transient recorder samples all eight channels simultaneously at 1 MS/s and triggers on envelope and level at the same time. Its setup is simplified with a Set and go option: predefined low and high trigger levels for current and voltage. The transient recorder runs while the general recorder and the waveform recorder are working, so a single connection captures slow trends, events and fast spikes together. The general recorder adds average ON values, 200 ms U/I/f data, rapid voltage change (RVC), inrush, transients and two selectable signalling frequencies to the usual minimum, maximum and average values.
Other functions match the Class A family: harmonics and interharmonics up to the 50th, flicker, unbalance, EN 50160 analysis, IEEE 1459 power measurement, VFD and 400 Hz support, temperature measurement and up to seven adjustable alarms.
Technical specifications
| Parameter | Specification |
|---|---|
| Voltage inputs | 5 inputs; three-phase connection phase (L-N) 50 to 1000 V RMS, line (L-L) 87 to 1730 V; single-phase connection 50 to 500 V RMS |
| Measuring range / accuracy | 10 % to 150 % of nominal (three-phase 10 % to 110 %); IEC 61000-4-30 Class A, +/-0.1 % of nominal voltage |
| Transients | Maximum transient peak voltage +/-6 kV; 1 MS/s on all 8 channels; one cycle of voltage and current waveform; envelope and level trigger |
| Current inputs | 4 inputs; clamps from 50 mA to 12000 A depending on clamp; accuracy +/-0.5 % to +/-1.5 % of measured value |
| Sampling | 7 kS/s at 50/60 Hz synchronised to mains; 1.7 kS/s for VFD (5 to 120 Hz); 12.2 kS/s at 400 Hz |
| Power and energy | IEC 61557-12 Class 1; energy IEC 62053-21 Class 1 (active), IEC 62053-23 Class 2 (reactive) |
| Harmonics / flicker | Harmonics and interharmonics to the 50th, IEC 61000-4-7 Class I; flicker IEC 61000-4-15 Class F1 |
| General recorder | Integration 1 s to 2 h; more than 1000 signals; min, max, average and average ON values; more than a year at a 10 minute period |
| Waveform recorder | Up to 60 s with 30 s pre-trigger; up to 1500 records |
| Memory | 8 GB microSD supplied, up to 32 GB supported |
| Display / communication | 4.3 inch colour TFT 480 x 272; USB and Ethernet; GPS time synchronisation (A 1355) |
| Overvoltage category | CAT IV / 600 V; CAT III / 1000 V for three-phase connection |
| Standards | IEC/EN 61000-4-30 Class A, IEC/EN 61557-12, IEC/EN 61000-4-7, IEC/EN 61000-4-15, EN 50160, IEEE 1459, IEEE 519; EN 61010-1; EN 61326 |
| Weight / dimensions | 1.1 kg; 230 x 140 x 80 mm |
When the XT is the better choice
The Class A functions of the standard Power Master are all present, so the XT matters when the problem is a fast disturbance: switching transients from capacitor banks, breaker operations, drive commutation or lightning-induced surges that are shorter than a mains cycle. For recurring faults, the combination of event capture, waveform recording and 1 MS/s transient recording lets the engineer see what happened before and after the trigger.
Metrel lists high-speed transient capturing, energy consumption optimisation, power quality assessment on low and medium voltage systems, power factor correction checks, long-term analysis, predictive maintenance and verifying the capacity of an electrical system before loads are added. Sets are Standard (without flexible clamps), Euro (flexible clamps included) and Advanced (A 1502 flexible clamps and accessories); a wide-range power supply, 4G / Wi-Fi router, GPS receiver, an EV monitoring cable and waterproof cases are optional.
What to confirm before ordering
Identify the transient levels you expect, the measuring points and whether the supply is three-phase or single-phase, since the voltage ranges differ between the two connection types. Confirm the clamp types for the conductors, GPS or remote-access needs, and the memory card size. The leaflet notes that specifications may change without notice.
Documents and quotation
The Metrel leaflet is attached as a datasheet. For continuous monitoring on a panel see the Janitza UMG 96RM panel power analyser; other portable instruments are in the portable test and measurement category. Send the set, clamps and quantity for a quotation from Seven Star LLC.
Datasheets & Documents
- Datasheet Metrel MI 2893 Power Master XT product leaflet (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrel is a Slovenian manufacturer of electrical installation testers and power quality instruments, based in Horjul near Ljubljana. It was set up in 1957 as a factory making electrical measuring instruments and components for the domestic market and grew into an exporter whose testers are sold through distributors in more than 70 countries. Metrel d.o.o. designs, builds and calibrates its instruments in Slovenia.
Seven Star LLC is an independent supplier in Muscat. We list Metrel testers for electrical contractors, utilities and maintenance teams in Oman and the GCC.
Metrel company profile
| Founded | 1957, Slovenia |
|---|---|
| Headquarters | Horjul, Slovenia (Metrel d.o.o.) |
| Group | Metrel Group of four companies: two in Slovenia, one in Germany and one in the United Kingdom |
| In-house services | Own R&D plus accredited calibration and repair departments |
| Product families | EurotestXC and Eurotest multifunction installation testers, earth and insulation resistance testers, PAT testers, PV installation testers, Power Master power quality analysers, machine and switchboard safety testers |
Milestones
- 1957: Metrel is set up as a factory for electrical measuring instruments.
- Today: Metrel instruments are sold through distributors in more than 70 countries.
Metrel product series
Installation testers include the MI 3152 EurotestXC and the MI 3155 EurotestXD for low-voltage installation verification, and the MI 3121 SMARTEC insulation and continuity tester. Insulation testers include the MI 3201 TeraOhm 5 kV Plus, the MI 3205 TeraOhmXA 5 kV with IP65 housing and the MI 3211 TeraOhmHP 10 kV. The MI 3242 MicroOhm 2A measures low resistance on joints, busbars and windings.
Earth testing is covered by the MI 3290 Earth Analyser and the MI 3288 earth insulation tester, and power quality by the MI 2892 Power Master and MI 2893 Power Master XT class A analysers and the MI 2885 Master Q4 class S analyser.
Where Metrel instruments are used
Verification of new and existing building installations, insulation testing of cables, motors and transformers, earthing and lightning protection measurements at substations and towers, and power quality surveys in industrial and commercial plants.
Metrel products we list
Ordering Metrel instruments: what we need
Give the complete model name and the set you want, because Metrel sells most instruments as standard, Euro or advanced sets with different leads, clamps and software licences. List accessories separately and state the standard your testing must follow. If you are unsure of the model, describe the installation, test voltage and measurements required.
Facts checked against Metrel's own company pages (metrel.si) and trade directories, October 2026.
Browse Metrel products by category: Portable Test & Measurement.
Related products
Frequently Asked Questions
1 MSamples per second, simultaneously on all eight channels.
Yes. It complies with IEC/EN 61000-4-30 Class A.
The leaflet states a maximum transient peak voltage of +/-6 kV.
A microSD card, 8 GB supplied and up to 32 GB supported.
The PowerView3 PC software, which reads the card, analyses long-term records and creates reports.

Reviews
There are no reviews yet.