Brand: WIKA
WIKA TC96-R Flex-R Flexible Multipoint Thermometer
Description
WIKA TC96-R Flex-R flexible multipoint thermometer for reactors
The WIKA TC96-R, sold by WIKA as the Flex-R, is a flexible multipoint thermocouple assembly for measuring temperature profiles inside catalytic reactors, regenerators and columns. Instead of one reading at one depth, a bundle of thin mineral-insulated cables carries up to 100 measuring points through a single nozzle and then spreads them through the catalyst bed, so hotspots, channeling and uneven flow show up as real readings. WIKA quotes a response time of 4 to 8 seconds. Seven Star LLC supplies the TC96-R in Oman and the GCC as an independent supplier in Muscat; this page describes the model variants and what must be defined for an RFQ.
What a multipoint thermometer does for a reactor
Refining and petrochemical units are asked to run longer between turnarounds, change catalysts and process new feeds. Temperature profiling gives early warning of maldistribution of the catalyst, hot spots and runaway conditions. The TC96-R is described by WIKA as offering real radial profiling, high point density, secondary containment, adaptability to existing reactor nozzles and greater process control. Each unit is engineered for the vessel, which is why many geometric details are marked as varying with the flange and the number of thermocouples.
TC96-R technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | WIKA / TC96-R Flex-R (data sheet TE 70.10) |
| Type | Flexible multipoint thermometer with MI cable thermocouples |
| Models | TC96-R-C (flange), TC96-R-R (Radial Tap), TC96-R-N (Radial Tap Nex Gen) |
| Thermocouple type | K, E or J, single or double element |
| MI cable diameter | 1/4 in (6.35 mm) or 5/16 in (7.94 mm) |
| MI cable sheath | Stainless steel 316, 308, 321, 347 or Inconel 600; others on request |
| Cable length | 0.3 … 20 m (1 … 150 ft) |
| Number of measuring points | 1 … 100 |
| Measuring point | Ungrounded or grounded |
| Response time | 4 to 8 seconds |
| Process connection materials | Stainless steel 321, 347, alloy 825 and other specialty steels |
| Flanges ASME B16.5 | 1 in … 12 in, class 150 … 2,500 |
| Flanges EN 1092-1 / DIN 2527 | DN 50 … DN 200, PN 16 … PN 100 |
| Containment | Primary and secondary containment, with pressure monitoring on the neck tube |
| Delivery | Shipped in a wooden box |
TC96-R-C, TC96-R-R and TC96-R-N compared
| Model | Connection concept | Typical use |
|---|---|---|
| TC96-R-C | Flange connection to the reactor nozzle | Existing flanged nozzles on the vessel |
| TC96-R-R | Flex-R with Radial Tap: cable bundles pass the shell at selected radial positions | Radial profile through the bed |
| TC96-R-N | Radial Tap Nex Gen | Same purpose, newer connector design |
The Radial Tap models use a high-pressure coupling, available in all required sizes and pressure ratings, with primary and secondary containment. Special connections to customer specification are listed, including welding sockets, flange connections and valves.
The five assemblies of a TC96-R
WIKA divides the instrument into five parts that are specified separately: the pressure monitoring arrangement, the neck tube including primary and secondary connection, the process connection, the multipoint MI cable bundle and the terminal enclosure. The terminal enclosure shown in the datasheet is only a sample, because its design depends on the application and is engineered individually for each assembly. Plan the field cabling and junction box location early, since 100 points may need a large enclosure.
Routing and length of the cable bundle
The correct length of each cable is critical, because it decides where the junction ends up inside the bed. The datasheet has a section on routing the MI cable inside the reactor: lengths must allow for catalyst settling and thermal expansion, so an assembly is built to the vessel drawing with the bed levels, nozzle position and desired point layout. Because the bundle is flexible, it can be inserted through a small nozzle and then positioned, which is what makes it suitable for retrofit to an existing reactor.
Sensor options and choosing them
Type K covers most reactor temperatures, type E gives a higher signal at moderate temperatures, and type J is used for lower ranges. Ungrounded junctions are less sensitive to electrical noise and ground loops, while grounded junctions respond slightly faster. Double elements give a redundant reading at the same point. For details on accuracy, WIKA refers to the technical information on thermocouples (IN 00.23).
Installation and operation
- Verify the nozzle dimensions, flange class and bolting before the assembly is built
- Keep the wooden crate until the reactor is ready, and lift the bundle without kinking the cables
- Check each point for continuity and insulation resistance before and after insertion
- Label each thermocouple and compare the profile with the process model after start-up
- Record baseline temperature profiles to compare during later runs
Applications in Oman and the GCC
The listed industry is refining and petrochemical, and the use cases are temperature profiles in reactors, regenerators and a range of columns. In the Gulf, hydrotreaters, hydrocrackers, reformers and polymer reactors are the normal places to find multipoint thermometers, where tight temperature control protects catalyst life and the vessel.
TC96-R ordering checklist
- Model variant: -C, -R or -N
- Reactor drawing with nozzle, flange standard and class
- Number and position of measuring points, and thermocouple type
- MI cable diameter and sheath material, and cable length
- Single or double element, grounded or ungrounded junctions
- Terminal enclosure, hazardous-area requirement and documentation
Information to send with an RFQ
Provide the reactor datasheet, the nozzle details, the number of points, material requirements and certification needs. A sketch or existing drawing of a previous multipoint assembly helps match dimensions.
Site conditions in Oman for the TC96-R
Field instruments in Oman are exposed to strong sun, high ambient temperature, wind-blown dust and, on coastal plants, salt in the air. When you specify the TC96-R, check the ambient and process temperature limits, the enclosure rating and the wetted and housing materials against the actual installation point, and consider sunshades for transmitters mounted in direct sunlight. Cable entries should be sealed with suitable glands so that dust and moisture cannot enter the housing.
Calibration and verification planning matters as much as selection. Record the range, configuration and tag data of each TC96-R at commissioning, define a check interval that suits the criticality of the loop, and keep the certificates with the plant documentation so that audits and shutdown work can proceed without delay.
Documents and quotation
The WIKA data sheet TE 70.10 for the TC96-R is attached on this page. Send us the specification and quantity for a quotation from Muscat as an independent supplier.
Other Models in the Wika Tc9x Range
Seven Star LLC supplies models from the Wika Tc9x range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| WIKA TC90 High-Pressure Thermocouple | Temperature Instrumentation | View details |
| WIKA TC96-R Flex-R Flexible Multipoint Thermometer | Temperature Instrumentation | You are viewing this model |
Datasheets & Documents
- Datasheet WIKA TC96-R Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
WIKA is the German manufacturer of pressure, temperature, level and flow instruments, best known for its pressure gauges. Alexander Wiegand and Philipp Kachel founded it on 2 January 1946 in Klingenberg am Main, Bavaria. The name comes from the first two letters of their surnames. WIKA is still run by the Wiegand family and is headquartered in Klingenberg.
Seven Star LLC is an independent supplier in Muscat. We list WIKA pressure gauges, diaphragm seals, transmitters, switches, thermometers and thermowells, and supply them to plants, contractors and panel builders in Oman and the GCC by model and order code.
WIKA company profile
| Established | 2 January 1946, Klingenberg am Main, Germany, by Alexander Wiegand and Philipp Kachel |
|---|---|
| First products | Mechanical pressure and temperature gauges |
| Ownership | Family-owned; managed by Alexander Wiegand, grandson of the founder, since 1996 |
| Product families | Pressure gauges, diaphragm seals, pressure transmitters and switches, thermometers, RTDs, thermocouples, thermowells, calibration equipment, level and flow instruments |
Milestones
- 1946: Alexander Wiegand and Philipp Kachel found the company in Klingenberg am Main on 2 January; pressure gauge production starts at the end of the year. The name WIKA comes from the first letters of their surnames.
- 1951: Konrad Wiegand, the founder's son, takes over management.
- 1967: Ursula Wiegand leads the company after her husband's death.
- 1986: The company is reunited with the Kachel thermometer factory, which Philipp Kachel had set up after leaving in 1956.
- 1994: Certification to DIN ISO 9001.
- 1996: Alexander Wiegand, the founder's grandson, becomes head of the company.
WIKA products we list
| Family | Models | Typical use |
|---|---|---|
| Bourdon tube pressure gauges | 111.10, 111.12, 212.20, 213.53, 232.50, 233.50, 232.30/233.30 safety pattern | HVAC and utilities (111 series) to process plants (23x series in stainless steel) |
| Diaphragm and differential pressure gauges | 432.50, 732.51, 700.01, DPGT43 | Low pressures, viscous or dirty media, and filter differential pressure |
| Diaphragm seals | 990.10, 990.27 | Separating the gauge from corrosive, hot or clogging media |
| Transmitters, switches and test gauges | A-10, UPT-20, PSM01, CPG1500 | 4-20 mA pressure signals, switching, and precision calibration checks |
| Thermometers | TG54, Model 55, A52, 73 gas-actuated | Local temperature indication on pipes, vessels and HVAC |
| Temperature sensors and thermowells | TR10, TR12-B, TR33, TC10-B, TW10 flanged, TW15 threaded | RTD and thermocouple measurement in process lines |
The WIKA model number tells you the build. In 232.50, the first digit 2 means stainless steel wetted parts, the second digit 3 means a liquid-fillable case, and ".50" is the case style. The 111 series uses copper alloy wetted parts and suits water and air. Where the medium is corrosive, very hot or would block the gauge, a diaphragm seal such as the 990.27 keeps it away from the Bourdon tube. For temperature, a thermowell like the TW10 lets you remove the sensor without opening the process.
Where WIKA instruments are used
In Oman and the GCC, WIKA gauges, transmitters and thermometers are used in oil and gas, refining and petrochemical plants, power and desalination, water networks, district cooling and HVAC, and on skids and machines from OEMs.
Ordering WIKA instruments: what we need
Send the model, dial size (for example 63, 100 or 160 mm), range and unit, connection size and position (lower or back mount), accuracy class and whether liquid filling is needed. For diaphragm seals and thermowells, add the process connection, materials and insertion length.
Facts checked against WIKA company history, October 2026.
Browse WIKA products by category: Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the WIKA TC96-R Flex-R Flexible Multipoint Thermometer
Answers from our engineering team on installation, compatibility and integration.
01What is the TC96-R used for?
It is used for measuring temperature profiles in reactors, regenerators and columns in refining and petrochemical plants, to detect hotspots, channeling and maldistribution.
02How many measuring points are possible?
One to 100 measuring points per assembly, using MI cables of 1/4 or 5/16 inch with lengths from 0.3 to 20 m.
03What are the model variants?
TC96-R-C has a flange connection, TC96-R-R has a Radial Tap, and TC96-R-N has a Radial Tap Nex Gen connection.
04How fast does it respond?
WIKA quotes a response time of 4 to 8 seconds.
05Which thermocouple types are used?
Types K, E and J, as single or double element, with ungrounded or grounded measuring points.


















Reviews
There are no reviews yet.