Brand: Turck
Turck TBEN-S2-4IOL Multiprotocol IO-Link Master Block
Description
TBEN-S2-4IOL compact multiprotocol IO-Link master block: what it is
The TBEN-S2-4IOL is a field-mounted Ethernet I/O block that combines four IO-Link master ports with a multiprotocol network interface. It is built for installation directly on a machine or skid, without a control cabinet. A single module speaks PROFINET, EtherNet/IP, Modbus TCP and CC-Link IE Field Basic, and it detects the active protocol automatically, so one stock item can serve plants that standardise on different PLC families. Seven Star LLC supplies TBEN-S2-4IOL in Oman and the GCC as an independent supplier in Muscat.
Each of the four M12 ports works as an IO-Link master channel (Class A) and also offers standard digital PNP signal channels. In practice the block lets you connect IO-Link sensors, valve terminals, indicators and simple switches to one Ethernet drop and read their process data, parameters and diagnostics from the PLC.
Technical specifications of the TBEN-S2-4IOL
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Turck TBEN-S2-4IOL |
| Ident number | 6814024 |
| Protocols | PROFINET device, EtherNet/IP device, Modbus TCP server, CC-Link IE Field Basic; automatic protocol detection |
| Fieldbus connection | 2 × M8, 4-pin, integrated Ethernet switch, 10/100 Mbps |
| Supply voltage | 24 VDC, admissible range 18…30 VDC, max. 4 A total per voltage group |
| Supply connection | 2 × M8, 4-pin, A-coded; galvanically isolated groups V1 and V2 |
| Operating current | V1 50…110 mA, V2 10…115 mA |
| IO-Link | 4 channels, specification V1.1, Class A ports, up to 32 bytes in / 32 bytes out per port |
| IO-Link transmission rates | 4.8 kbps (COM 1), 38.4 kbps (COM 2), 230 kbps (COM 3) |
| Digital channels | 4 DXP + 4 SIO, PNP, M12 5-pin, channel diagnostics |
| Output rating | 0.5 A per channel, short-circuit proof; resistive, inductive and lamp loads |
| Input thresholds | Low <5 V, high >11 V; SIO per EN 61131-2 type 1, DXP type 3 |
| Ambient temperature | -40…+70 °C (storage -40…+85 °C) |
| Protection | IP65, IP67, IP69K |
| Housing | PA6-GF30 black, nickel-plated brass connectors, fully potted electronics |
| Dimensions (W × L × H) | 32 × 144 × 32 mm |
| Approvals listed | CE, UKCA, ATEX zone 2/22, CCC-Ex, cULus listed, FCC statement |
| MTTF | 260 years per SN 29500 at 20 °C |
How the TBEN-S2-4IOL works
The module sits between the plant Ethernet network and the sensors and actuators on the machine. On the network side, the two M8 Ethernet ports are linked through an internal switch, so blocks can be daisy-chained in a line topology instead of running every cable back to a central switch. The protocol stack is selected automatically from the first connection request, which removes the need for separate part numbers per PLC brand.
On the field side, each port acts as an IO-Link master. The master cyclically exchanges process data with the connected device, and it can also read and write parameters and pass device events to the controller. Pin 4 of each M12 port carries the IO-Link signal, while pin 2 can serve as an extra digital input or output. When a port is set to standard digital mode, it behaves like an ordinary PNP channel with channel-level diagnostics.
On PROFINET the block is conformance class B (RT) with a minimum cycle time of 1 ms, fast start-up under 500 ms, topology detection, automatic addressing, MRP support and S2 system redundancy. On EtherNet/IP it supports quick connect under 500 ms, a minimum RPI of 2 ms and Device Level Ring. On Modbus TCP it offers static IP or DHCP, eight TCP connections and the common function codes FC1, FC2, FC3, FC4, FC6, FC15, FC16 and FC23. The block also supports ARGEE, Turck’s programmable logic function, so simple local logic can run without a PLC round trip.
System fit and related parts
Within the Turck TBEN family, the S2 housing is the compact 32 mm wide variant with M8 connectors for Ethernet and power. Larger L-series blocks such as the TBEN-L5-8IOL offer eight IO-Link channels in a wider housing, while other S-series blocks such as the TBEN-S2-8DIP and TBEN-S1-8DXP-type digital blocks provide only plain digital I/O. The TBEN-S2-4IOL is the choice when the machine needs IO-Link flexibility in a small footprint.
Typical field devices include IO-Link proximity and level sensors, pressure and temperature transmitters, pneumatic valve manifolds, signal beacons and RFID heads. Cables are standard M12 IO-Link cordsets; the datasheet names a 4-pole IO-Link cable as an example accessory, and a separate external supply cable is required if a Class B device is to be fed from its own supply.
Selection and ordering checklist for TBEN-S2-4IOL
- Confirm that the PLC speaks PROFINET, EtherNet/IP, Modbus TCP or CC-Link IE Field Basic.
- Count IO-Link devices and check that each needs no more than 32 bytes in and 32 bytes out.
- Check whether any device is Class B, which needs an external supply arrangement.
- Confirm that total current for ports C0 to C3 stays within 4 A per group, and that each output stays within 0.5 A.
- Verify the ATEX zone 2/22 note and read the Quick Start Guide before use in a hazardous area.
- Check the firmware version: from 3.1.10.0 the ports are numbered C0 to C3 and channels CH0 to CH3, which affects PLC addressing.
Installation, commissioning and maintenance of the TBEN-S2-4IOL
Mount the block with its two 4.6 mm holes on a flat surface. Use the 4-pin M8 power connectors for V1 and V2; keeping the two voltage groups separate lets you switch off the actuator supply while the network and diagnostics stay alive. Connect Ethernet to P1 or P2, assign the address through DCP, DHCP or BootP, and reach the built-in web server on its default address for setup and service.
The status LEDs separate network, bus, diagnostics and power conditions. A green PWR LED means both V1 and V2 are healthy, a red PWR LED points to a missing or low V2 or V1, and the ERR LED turns red when diagnostics are waiting. The BUS LED shows an active master connection, an address conflict or a Modbus timeout. Because the electronics are fully potted and the housing is rated up to IP69K, maintenance is mainly limited to checking connectors, torque on M12 plugs and cable condition, and keeping spare blocks for fast swap-out. IO-Link parameters of attached devices can be restored to the master after a device replacement when the PLC project supports it.
Typical applications in Oman and the GCC
In Oman and across the Gulf, machine-mounted I/O must tolerate heat, dust, washdown and salt-laden air. The IP67/IP69K rating and the wide -40 to +70 °C range suit skid packages, pump and compressor skids, water treatment and desalination plants, and packaging or bottling lines. Oil and gas and petrochemical sites often run EtherNet/IP or PROFINET on different packages; a multiprotocol block simplifies spares. Where installation is in an ATEX zone 2/22 area, the listed approval and the manual’s Ex instructions must be followed for the exact installation.
Variants and family comparison
| Item | Focus | Housing |
|---|---|---|
| TBEN-S2-4IOL | 4 IO-Link master channels plus digital I/O, multiprotocol | Compact, M8 Ethernet |
| TBEN-L5-8IOL | 8 IO-Link master channels, PROFINET | Larger L-series |
| TBEN-S2-8DIP | 8 PNP inputs, PROFINET | Compact S-series |
Choose the TBEN-S2-4IOL when you want a few IO-Link ports and flexible protocol support. If you need more ports or a different housing, state the channel count in your RFQ and we will suggest a matching Turck block.
Information to send with an RFQ for TBEN-S2-4IOL
- PLC brand and protocol, plus firmware generation if known.
- Number and type of IO-Link devices, and any Class B devices.
- Required digital inputs and outputs and their load currents.
- Ambient temperature, washdown exposure and hazardous-area classification.
- Cable types and lengths for Ethernet, power and IO-Link.
- Quantity and delivery location in Oman or the GCC.
Documents and quotation
The manufacturer datasheet for the TBEN-S2-4IOL is attached on this page for your reference. It lists the electrical data, protocol details, LED behaviour and connector pinouts.
Send your required quantity and application details and Seven Star LLC will prepare a quotation for the TBEN-S2-4IOL for delivery in Oman and the GCC.
See also: Turck TBPN-L5-4FDI-4FDX PROFIsafe I/O Block 4 Safe Inputs 4 Safe.
Datasheets & Documents
- Datasheet Turck TBEN-S2-4IOL Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Turck is the German automation company for sensors, connectivity, fieldbus I/O and interface technology. It grew from Hans Turck's engineering office in Mülheim an der Ruhr: in 1965 a chemical plant ordered an isolation amplifier for intrinsically safe circuits, and the first 20 units were built by his brother Werner Turck in Halver. The family-owned Turck group is still headquartered in Mülheim an der Ruhr, with production in Halver and other sites.
Seven Star LLC is an independent supplier in Muscat. We list Turck sensors and I/O devices for machine builders and maintenance teams in Oman and the GCC.
Turck company profile
| Founded | 1965, Germany, by the brothers Hans and Werner Turck |
|---|---|
| First product | An isolation amplifier with intrinsically safe circuits for explosion-protected areas, first supplied to Chemische Werke Hüls |
| Headquarters | Mülheim an der Ruhr, Germany; production in Halver |
| Ownership | Family-owned group; Turck Holding was formed in 1994 |
| Product families | Inductive, capacitive and ultrasonic sensors, TBEN block I/O and fieldbus modules, IO-Link masters and hubs, connectors and cordsets, isolating barriers and interface modules, RFID systems |
Milestones
- 1965: An order from a German chemical plant for an amplifier module starts the business; Werner Turck builds the first 20 units.
- 1970: Hans Turck KG and Werner Turck KG are registered as separate companies.
- 1975: Hans Turck KG opens its building in Mülheim an der Ruhr.
- 1994: Turck Holding combines the two Turck companies under one roof.
Turck product series
Most of the Turck products here are inductive proximity sensors: threaded M12, M18 and M30 barrels in flush (BI) and non-flush (NI) versions, uprated-range (U) sensors, rectangular CP40 and CP80 housings and BIM magnetic-field sensors for detecting pistons in pneumatic cylinders. The type code describes the sensor; in BI5-M18-AP6X-H1141, BI means flush mounting, 5 is the switching distance in mm, AP6X a three-wire PNP output and H1141 the M12 connector.
Turck also makes RU ultrasonic sensors, PS pressure, TS temperature and LS level sensors, FCI inline flow sensors, the CMVT vibration and temperature sensor for condition monitoring over IO-Link, and fieldbus and Ethernet I/O modules and communication components.
Where Turck sensors are used
Position detection on conveyors, packaging machines, presses and robotic cells; level, pressure and temperature monitoring on hydraulic units and process skids; and vibration monitoring on motors, pumps and fans.
Turck products we list
Ordering Turck sensors: what we need
Send the full type code and the six- or seven-digit ID number printed on the sensor or its label. If the label is missing, give the housing size, flush or non-flush mounting, switching distance, output type (PNP or NPN, NO or NC), supply voltage and connection (cable or connector).
Facts checked against Turck's published company history, October 2026.
Browse Turck products by category: Inductive Proximity Sensors, Flow Indicators & Switches, Level Instrumentation, Pressure Instrumentation, Temperature Instrumentation, Vibration Monitoring.
FAQ
Questions about the Turck TBEN-S2-4IOL Multiprotocol IO-Link Master
Answers from our engineering team on installation, compatibility and integration.
01Which industrial protocols does the TBEN-S2-4IOL support?
PROFINET, EtherNet/IP, Modbus TCP and CC-Link IE Field Basic. The module detects the protocol automatically.
02How many IO-Link channels does it have?
Four Class A IO-Link V1.1 master channels on M12 5-pin ports. Each port handles up to 32 bytes in and 32 bytes out.
03What is its operating temperature and protection rating?
Ambient temperature is -40 to +70 degrees C. Protection classes IP65, IP67 and IP69K are listed.
04How is the block powered?
24 VDC (18 to 30 VDC) through 4-pin M8 connectors, with galvanically isolated voltage groups V1 and V2.
05Is it approved for hazardous areas?
The datasheet lists ATEX zone 2/22 and CCC-Ex, and notes that the Quick Start Guide must be observed for Ex use.