Brand: Turck
Turck TBPN-L1-FDIO1-2IOL PROFIsafe I/O Block 2 Safe Inputs 2
Description
About the TBPN-L1-FDIO1-2IOL
TBPN-L1-FDIO1-2IOL is a compact PROFIsafe and PROFINET block I/O module that combines safe digital inputs and outputs rated SIL 3 with standard universal digital channels and IO-Link master ports.
Feature list printed by the manufacturer: ATEX zone 2/22; Glass fiber reinforced housing; Shock and vibration tested; 100 Mbps supported; 5-pin 7/8″ male connector for power supply; 2 × M12, 4-pin, D-coded, Ethernet fieldbus; Two secure digital SIL3-inputs; Four secure digital SIL3 FDI channels; Protection classes IP65, IP67, IP69K.
Technical specifications
| Parameter | Specification |
|---|---|
| Type | TBPN-L1-FDIO1-2IOL |
| Ident number | 6814053 |
| Supply voltage | 24 VDC |
| Admissible range | 20.4…28.8 VDC |
| Voltage supply connection | 7/8″, 5-pin |
| Power dissipation, typical | ≤5W |
| Fieldbus transmission rate | 100 Mbps |
| Fieldbus connection technology | 2 x M12, 4-pin, D-coded |
| Web server | integrated |
| Service interface | Ethernet via P1 or P2 |
| Addressing | DCP |
| Conformance class | B (RT) |
| MinCycleTime | 1 ms |
| Topology detection | supported |
| Automatic addressing | supported |
| Media Redundancy Protocol (MRP) | supported |
| PL acc. to EN ISO 13849-1 | Level e |
| Category acc. to DIN EN 13849-1:2008 | 4 |
| SIL acc. to IEC 61508 | 3 |
| Useful Lifetime | 20 years (EN ISO 13849-1) |
| Safety Inputs OSSD | Figure 2 |
| Low-level signal voltage | EN 61131-2 Type 1 ( < 5 V; < 0.5 mA) |
| High-level signal voltage | EN 61131-2 Type 1 ( > 15 V; > 2 mA) |
| Max. tolerance test pulse width | 1 ms |
| Interval between 2 test pulses, minimum | 20 ms at 1 ms test pulse width |
| Max. loop resistance | < 150 Ω |
| Max. cable length | max. 1 uF at 150 Ω |
| Test pulse, typical | 0.6 ms |
| Test pulse, maximum | 0.8 ms |
| Sensor supply | Versorgung V AUX1/T1 max. 2 A |
| Additional information | no connection to external potential allowed |
| Output current in off state | < 5 V |
| Interval between 2 test pulses, typical | 500 ms |
| Actuator power supply | Versorgung V AUX1/T1 max. 2 A |
| Max. output current | 2 A (resistive) |
| Connectivity inputs | M12, 5-pin |
Typical use and installation notes
Safety and standard signals share one housing and one network cable, so an emergency stop, a light curtain and a few ordinary sensors can all be wired at the machine. The datasheet lists safety rating SIL 3 according to IEC 61508 and performance level e according to EN ISO 13849-1, with two secure inputs and secure channels that can work as inputs or outputs, plus IO-Link ports for smart sensors. The safety function still has to be validated in the machine, using the manual and the safety documents.
Commissioning of any safety node needs a documented validation: check each safety channel, the reaction time and the diagnostics in the safety controller, and keep the manual and certificates in the machine file.
Selection check before ordering
TBPN is the Turck PROFINET and PROFIsafe block family; the datasheet title lists the safe digital channels (FDI inputs, FDX configurable channels), standard channels and IO-Link ports in this module. Ident number 6814053 identifies this exact module.
Points to confirm with us before ordering: the PROFIsafe parameters of your safety controller, the connector types, the safety function and required SIL or performance level for each channel, and the supply range and the hazardous-area conditions in the manual. Everything in the table comes from the datasheet as published, so the maker document is the final reference.
Documents and quotation
Download the Turck datasheet for TBPN-L1-FDIO1-2IOL and compare it with your drawing or loop data. Pricing and lead time are not shown on the page; Seven Star LLC, an independent supplier based in Muscat, quotes them on request. Quote the full type code TBPN-L1-FDIO1-2IOL so the correct variant is offered. More related items are listed under PLC & I/O Cards.
Datasheets & Documents
- Datasheet Turck TBPN-L1-FDIO1-2IOL Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Turck is the German automation company for sensors, connectivity, fieldbus I/O and interface technology. It grew from Hans Turck's engineering office in Mülheim an der Ruhr: in 1965 a chemical plant ordered an isolation amplifier for intrinsically safe circuits, and the first 20 units were built by his brother Werner Turck in Halver. The family-owned Turck group is still headquartered in Mülheim an der Ruhr, with production in Halver and other sites.
Seven Star LLC is an independent supplier in Muscat. We list Turck sensors and I/O devices for machine builders and maintenance teams in Oman and the GCC.
Turck company profile
| Founded | 1965, Germany, by the brothers Hans and Werner Turck |
|---|---|
| First product | An isolation amplifier with intrinsically safe circuits for explosion-protected areas, first supplied to Chemische Werke Hüls |
| Headquarters | Mülheim an der Ruhr, Germany; production in Halver |
| Ownership | Family-owned group; Turck Holding was formed in 1994 |
| Product families | Inductive, capacitive and ultrasonic sensors, TBEN block I/O and fieldbus modules, IO-Link masters and hubs, connectors and cordsets, isolating barriers and interface modules, RFID systems |
Milestones
- 1965: An order from a German chemical plant for an amplifier module starts the business; Werner Turck builds the first 20 units.
- 1970: Hans Turck KG and Werner Turck KG are registered as separate companies.
- 1975: Hans Turck KG opens its building in Mülheim an der Ruhr.
- 1994: Turck Holding combines the two Turck companies under one roof.
Turck product series
Most of the Turck products here are inductive proximity sensors: threaded M12, M18 and M30 barrels in flush (BI) and non-flush (NI) versions, uprated-range (U) sensors, rectangular CP40 and CP80 housings and BIM magnetic-field sensors for detecting pistons in pneumatic cylinders. The type code describes the sensor; in BI5-M18-AP6X-H1141, BI means flush mounting, 5 is the switching distance in mm, AP6X a three-wire PNP output and H1141 the M12 connector.
Turck also makes RU ultrasonic sensors, PS pressure, TS temperature and LS level sensors, FCI inline flow sensors, the CMVT vibration and temperature sensor for condition monitoring over IO-Link, and fieldbus and Ethernet I/O modules and communication components.
Where Turck sensors are used
Position detection on conveyors, packaging machines, presses and robotic cells; level, pressure and temperature monitoring on hydraulic units and process skids; and vibration monitoring on motors, pumps and fans.
Turck products we list
Ordering Turck sensors: what we need
Send the full type code and the six- or seven-digit ID number printed on the sensor or its label. If the label is missing, give the housing size, flush or non-flush mounting, switching distance, output type (PNP or NPN, NO or NC), supply voltage and connection (cable or connector).
Facts checked against Turck's published company history, October 2026.
Browse Turck products by category: Inductive Proximity Sensors, Flow Indicators & Switches, Level Instrumentation, Pressure Instrumentation, Temperature Instrumentation, Vibration Monitoring.
Related products
Frequently Asked Questions
The datasheet lists SIL 3 acc. to IEC 61508 and performance level Level e acc. to EN ISO 13849-1.
PROFINET with PROFIsafe for the safety data, with an integrated Ethernet switch and two M12 D-coded Ethernet ports.
24 VDC, admissible range 20.4…28.8 VDC.
IP65 in the datasheet, with IP67 and IP69K named in the feature list; ambient temperature -40…+70 °C.
Confirm the PROFIsafe parameters of your safety controller, the connector types, the safety function and required SIL or performance level for each channel, and the supply range and the hazardous-area conditions in the manual.