Brand: ABB
ABB ACS580-01-088A-4 Wall-Mounted Drive 45 kW 88 A
Description
A 45 kW ACS580 on a 400 V supply
ACS580-01-088A-4 is the wall-mounted ACS580 type that ABB rates for 45 kW at 400 V. Nominal output is 88 A at 45 kW, in frame R5. Use cases include mixers and conveyors and compressors in water works. Harmonic reduction comes from the built-in swinging choke, and the standard drive includes an EMC filter, Modbus RTU and SIL 3 Safe Torque Off.
Technical specifications
| Parameter | Specification |
|---|---|
| Type designation | ACS580-01-088A-4 |
| Product family | ACS580-01, wall-mounted general purpose drive |
| Supply voltage | 3-phase 380 to 415 V (400 V table) |
| Light-overload use | 45 kW, 82.7 A |
| Heavy-duty rating | 72 A = 37 kW; 150% for 1 min per 10 min |
| Maximum output current | 122 A |
| Frame size | R5 |
| IP21 size (H x W x D) | 732 mm with glandbox (596 mm without) x 203 x 295 mm |
| Mass in IP21 | 28.5 kg |
| IP55 option +B056 | 732 x 203 x 320 mm, 29 kg |
| Heat dissipation | 1156 W |
| Air flow | 280 m3/h |
| Maximum noise level | 62 dBA |
| Input fuses | 100 A gG, UL class T 110 A |
| Safety | Safe Torque Off (SIL 3) |
Duty classes, protection and cooling
The catalogue lists 82.7 A (45 kW) for light-overload use and 72 A (37 kW) for heavy duty, with a nominal 88 A and a peak of 122 A. Overload capability: 110% in light-overload use, 150% in heavy duty, each for 1 minute per 10 minutes at 40 degrees C. Use the light-overload column for pumps and fans and the heavy-duty column for constant-torque loads.
For the supply the catalogue recommends 100 A gG fuses or 110 A class T fuses for UL. Allow 1156 W of heat loss, 280 m3/h of air flow and a maximum of 62 dBA in cabinet and room design. Rated at 40 degrees C for R4 to R9; derate for 50 degrees C.
For wall mounting reserve 203 mm by 732 mm and 295 mm of depth; the IP21 unit weighs 28.5 kg. ABB offers the same drive in IP55 (+B056) measuring 732 x 203 x 320 mm and weighing 29 kg.
Reading the type code
In the code ACS580-01-088A-4 the 1 marks the wall-mounted drive, the current figure is 88 A and the final 4 is the 380 to 480 V class. Fieldbus and I/O options include +L512 for CHDI-01 115/230 V digital inputs, +K454 for FPBA-01 PROFIBUS DP, +K457 for FCAN-01 CANopen. EMC: C2 for wall-mounted drives and cabinets up to frame R9, C3 for modules and the R10 to R11 cabinets. Frames above R3 have no built-in brake chopper, so external braking hardware is used on this size.
Related ABB products: ABB ACQ580-01-089A-4 Water Drive 45 kW 89 A, ABB ACS550-01-087A-4 AC Drive 45 kW 87 A, ABB ACH580-01-088A-4 HVAC AC Drive 45 kW 88 A, ABB ACQ580-01-018A-4 Water Drive 7.5 kW 17 A, ABB ACQ580-01-039A-4 Water Drive 18.5 kW 38 A and ABB ACS580-01-018A-4 AC Drive 7.5 kW 17 A.
Documents and quotation
This page follows the linked ACS580 catalogue (3AUA0000145061, Rev G) and the ABB product page for the ACS580-01-088A-4. To request the ACS580-01-088A-4, send Seven Star LLC the motor data and supply details; availability is given in the quotation. Confirm before ordering: the full type code, plus options, motor current, enclosure, braking, fuses and derating for temperature and altitude, using the hardware manuals 3AXD50000018826 and 3AXD50000015497. A quotation request is quickest when it names the motor kW and nameplate current, the supply voltage and frequency, the required enclosure class and any fieldbus the ACS580-01-088A-4 must talk to. More sizes sit in AC drives, and the ABB ACS580 page introduces the family.
Datasheets & Documents
- Catalog ABB general purpose drives ACS580 catalog 3AUA0000145061 (Rev G) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB ACS580-01-088A-4 Wall-Mounted Drive 45 kW 88 A
Answers from our engineering team on installation, compatibility and integration.
01What are the duty ratings of the ACS580-01-088A-4?
ABB lists 88 A nominal (45 kW), 82.7 A (45 kW) light overload, 72 A (37 kW) heavy duty and 122 A maximum output current.
02What construction is the ACS580-01-088A-4?
It is the wall-mounted ACS580-01 in frame R5, IP21 as standard and IP55 with the +B056 option.
03How much heat does the ACS580-01-088A-4 produce?
The catalogue gives 1156 W of heat dissipation, 280 m3/h of air flow and 62 dBA of noise.
04Does the ACS580-01-088A-4 include Safe Torque Off?
Yes. Safe Torque Off (SIL 3) is part of the standard drive according to the ACS580 catalogue.
05Which fieldbus options fit the ACS580-01-088A-4?
The catalogue lists FDNA-01, FPBA-01, FCAN-01, FSCA-01, FCNA-01, FECA-01, FEPL-02, FENA-11 and FENA-21 adapters; Modbus RTU is built in.