Brand:

Hydac RFM Tank-Top Return Line Filter

Description

Overview

The Hydac RFM is a family of tank-top mounted return line filters that clean the oil flowing back to the reservoir of a hydraulic or lubrication system. The housing consists of an aluminium filter head with a 4-hole flange, a filter bowl and a screw-on cover, and every version has a bypass valve and a connection for a clogging indicator. Thirteen sizes of the Hydac RFM, from RFM 75 to RFM 851, cover flow rates up to 850 l/min at up to 10 bar, so the same product family can protect a small mobile power pack and a large industrial hydraulic station.

Seven Star LLC supplies the Hydac RFM to industrial and oil and gas customers in Oman and the GCC, with engineering support in Muscat. The Hydac RFM datasheet on this page describes the 4-hole mounting version of the family, so buyers should send us the exact order code, which encodes the filter size, element material, rating, port type and clogging indicator, and we will confirm availability of the complete filter or of replacement elements.

Operating Principle

A return line filter sits in the path of the oil that returns from actuators, valves and coolers to the tank, so it traps wear particles and contamination before they can re-enter the pump suction. In the Hydac RFM the returning oil passes through the filter element before it reaches the tank. If the element becomes loaded with dirt, the differential pressure rises until the clogging indicator responds at its 2 bar default setting, and the bypass valve opens at 3 bar so that the machine is not starved of return flow while the element waits for replacement.

The choice of element decides the cleanliness that a system with the Hydac RFM achieves. Optimicron® elements are offered in ratings from 1 to 20 µm and are stable to 20 bar, Ecomicron® elements are offered from 3 to 20 µm, paper elements in 10 and 20 µm, stainless wire mesh from 25 to 200 µm, and Betamicron®/Aquamicron® elements for water absorption in the larger sizes. The manufacturer states that its elements are validated and quality-monitored to ISO 2941, 2942, 2943, 3724, 3968, 11170 and 16889, which gives engineers a documented basis for cleanliness targets and filter sizing.

Engineering Design of the Hydac RFM

The Hydac RFM is a two-piece housing in which the aluminium head carries the ports and the bowl holds the element. The Hydac RFM bowl is made of polyamide on most sizes and of steel on RFM 210, 270 and 600, and the cover is polyamide on RFM 75 to 270 and aluminium on RFM 330 to 851. Port options of the Hydac RFM range from G 1/2 threads on the smallest sizes to SAE DN 65 flanges on RFM 661 and 851, and several sizes can carry an additional inlet. Seals are NBR as standard, with FKM seals available through the supplementary code V.

Installation of the Hydac RFM is practical. The filter is mounted on the top of the tank with four screws and must be installed absolutely vertically, so the housing and element hang into the oil volume. The datasheet requires the housing to be earthed, warns that the filter must not be used as a suction filter and states that components such as coolers must not be installed downstream of the filter. Optional features include a tank breather built into the head on RFM 75 to 270, a dipstick on selected sizes, a filling connection through the return line element on RFM 330 and above, and extension tubes to lengthen the filter on request. Clogging indicators are fitted in the VR (G 1/2) or VMF (G 1/8) port, and their position is selected by a type code.

Key Features

The Hydac RFM combines a robust housing with a very wide choice of elements. Its main characteristics are:

  • Thirteen sizes from RFM 75 to RFM 851, covering flow rates up to 850 l/min at up to 10 bar nominal pressure.
  • Aluminium filter head with a 4-hole flange for rigid tank-top mounting.
  • Bypass valve fitted as standard, with a default cracking pressure of 3 bar.
  • Connection for a visual, electrical or combined clogging indicator in the VR (G 1/2) or VMF (G 1/8) port.
  • Choice of Optimicron®, Ecomicron®, paper, stainless wire mesh, Betamicron®/Aquamicron®, Aquamicron® and Mobilemicron® elements.
  • Filtration ratings from 1 µm up to 200 µm depending on element material.
  • Compatible with mineral oils, biodegradable fluids and HFA, HFB, HFC and HFD fire-resistant fluids.
  • Optional tank breather, dipstick, filling port, extension tube and FKM seals for special installations.

Industrial Applications

Return line filters of this type protect the servo valves, proportional valves, pumps and motors of hydraulic circuits, and the Hydac RFM is used wherever a tank-top installation is practical: machine tool and press hydraulics, power packs for wellhead and valve control, lifting and handling equipment in ports such as Sohar and Salalah, and lubrication or gearbox circuits on rotating equipment. Compatibility with mineral oils, biodegradable fluids and HFA to HFD fire-resistant fluids means the same filter family can be specified for different fluid policies across a site.

In the hot desert climate of Oman and the GCC, dust ingress and elevated oil temperatures make filter maintenance critical, and the clogging indicator of the Hydac RFM tells technicians when to change the element before the bypass opens. For spare elements and related filtration hardware, buyers can also review the Bosch Rexroth R928006678 hydraulic filter element, the Parker 9000040001 coalescing filter element and the mobile filtration system for water treatment in our catalog. Seven Star LLC can help translate a system flow rate, viscosity and target cleanliness into a suitable RFM size and element rating.

Technical Specifications

Key parameters of the Hydac RFM return line filter taken from the manufacturer datasheet for the 4-hole mounting version:

Parameter Specification
Model Hydac RFM (RFM 75, 90, 150, 165, 185, 195, 210, 270, 330, 500, 600, 661, 851)
Design Tank-top mounted return line filter with 4-hole flange mounting, bypass valve fitted as standard
Flow rate / pressure Up to 850 l/min, up to 10 bar nominal pressure (7 bar version with clogging indicator, code V)
Temperature range -30 °C to +100 °C (short-term -40 °C)
Filter head material Aluminium (all sizes)
Filter bowl material Polyamide (all except RFM 210, 270, 600); steel for RFM 210, 270 and 600
Cover material Polyamide RFM 75 to 270; aluminium RFM 330 to 851
Bypass cracking pressure 3 bar (others on request)
Clogging indicator VR (thread G 1/2) or VMF (thread G 1/8, return line indication); setting 2 bar (others on request)
Indicator types Plastic or steel blanking plug, visual, electrical, or visual and electrical
Seals NBR (FKM on request, supplementary code V)
Filter element materials Optimicron® (ON), Ecomicron® (ECON2), paper (P/HC), stainless wire mesh (W/HC), Betamicron®/Aquamicron® (BN4AM), Aquamicron® (AM), Mobilemicron® (MM)
Filtration ratings ON 1 .. 20 µm; ECON2 3 .. 20 µm; P/HC 10 and 20 µm; W/HC 25 .. 200 µm; BN4AM 3 and 10 µm; AM 40 µm; MM 10 and 15 µm
Element pressure stability ON 20 bar; ECON2 10 bar; W/HC 20 bar; P/HC 10 bar; BN4AM, AM and MM 10 bar
Connection options Thread G 1/2 up to G 1 1/2, SAE DN 40, DN 50 and DN 65, depending on size; additional inlet ports for several sizes
Compatible fluids Mineral hydraulic oils H to HLPD (DIN 51524), lubricating and compressor oils, biodegradable fluids (HETG, HEES, HEPG), HFA, HFB, HFC and HFD fire-resistant fluids
Element validation standards ISO 2941, 2942, 2943, 3724, 3968, 11170, 16889
Installation Tank-top, mounted vertically; not for use as a suction filter
Optional equipment Tank breather in head (RFM 75 to 270), dipstick (RFM 75, 165, 185, 195), filling port, extension tube, FKM seals, HFA/HFC version

Request a Quote for Hydac RFM

To request a quotation for the Hydac RFM return line filter, check current availability and lead time or download the manufacturer datasheet from the document tab on this page, send the filter size, element material and rating, port type, clogging indicator type and operating pressure to the Seven Star LLC instrumentation team. We supply the Hydac RFM and its replacement elements to customers in Oman and the GCC.

Other Hydac models from Seven Star LLC: Hydac SB330 bladder accumulator, Hydac EDS 3400 electronic pressure switch and Hydac ETS 1700 electronic temperature switch.

Datasheets & Documents
  • PDF Datasheet Hydac RFM Return Line Filter Datasheet (4-hole mounting, E 7.106.1.2) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac RFM Tank-Top Return Line Filter

Answers from our engineering team on installation, compatibility and integration.

01What is the Hydac RFM return line filter designed for?
The Hydac RFM is a tank-top mounted return line filter that cleans oil returning to the reservoir of hydraulic and lubrication systems. It has a 4-hole flange, a bypass valve and a clogging indicator connection, and covers flows up to 850 l/min at up to 10 bar.
02Which element materials and filtration ratings are available for the Hydac RFM?
The datasheet lists Optimicron® (1 to 20 µm), Ecomicron® (3 to 20 µm), paper (10 and 20 µm), stainless steel wire mesh (25 to 200 µm), Betamicron®/Aquamicron® and Aquamicron® for larger sizes, and Mobilemicron® (10 and 15 µm). Availability depends on the filter size.
03How is the Hydac RFM installed?
It is mounted on the top of the tank with its 4-hole flange and must be installed vertically. The housing must be earthed, it must not be used as a suction filter, and no components such as coolers may be fitted after the filter.
04Which fluids and temperatures does the Hydac RFM support?
The nominal temperature range is -30 to +100 °C, with short-term operation to -40 °C. Compatible fluids include mineral hydraulic oils H to HLPD, lubricating and compressor oils, biodegradable HETG, HEES and HEPG fluids and HFA to HFD fire-resistant fluids.
05Where can I source the Hydac RFM in Oman?
Seven Star LLC supplies the Hydac RFM and replacement elements to customers in Oman and the GCC, with engineering support in Muscat. Please send the full order code or the system flow, viscosity and cleanliness target so the team can confirm the correct version.