Parker WPF405QEBM2KY201 High Pressure Filter WPF4 5 Micron
Description
WPF405QEBM2KY201 WPF4 high pressure filter with bypass and visual indicator
The Parker WPF405QEBM2KY201 is a size 4 member of the WPF high pressure filter series, built for hydraulic lines up to 414 bar (6000 psi). It carries a 5 micron microglass element, a 50 psid bypass valve, a visual indicator and 1-1/4 inch SAE code 62 flange ports. The product page quotes a flow of 416 l/min (110 gpm), which makes it one of the larger filters in the range. Unlike the no-bypass WPF3 configuration, this one lets oil bypass the element in a controlled way when it is cold or blocked, and the indicator tells the operator when to service it. Seven Star LLC supplies the WPF405QEBM2KY201 in Oman and the GCC.
Decoding WPF405QEBM2KY201
In the WPF how-to-order table WPF is the series and 4 selects the 1-1/4 inch nominal port size. 05QE is the media: 5 micron microglass in a standard-collapse element rated for 300 psid. B is nitrile seals, M2 is the 50 psi visual indicator, and K is the 50 psid (3.5 bar) bypass valve. Y20 is the port code, a 1-1/4 inch SAE code 62 flange face, and the closing 1 is the option that identifies a bypass filter with a standard element. When an indicator is chosen, the indicator port is plugged and the indicator is shipped as a loose part, so it is fitted at installation.
WPF405QEBM2KY201 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker WPF405QEBM2KY201 |
| Series / size | WPF high pressure in-line filter, size 4 (1-1/4 inch nominal ports) |
| Element | 05QE: 5 micron microglass, standard collapse (300 psid / 21 bar), coreless with reusable core; replacement element 941039Q |
| Bypass | K: 50 psid (3.5 bar) bypass valve, option 1 |
| Indicator | M2: 50 psi visual indicator |
| Seals | Nitrile (code B) |
| Ports | Y20: 1-1/4 inch SAE code 62 flange face |
| Maximum operating pressure | 414 bar (6000 psi); rated fatigue pressure 414 bar; design safety factor 3:1 |
| Rated flow | 416 l/min (110 gpm) per product page |
| Fluids | Mineral, petroleum and PAO-based fluids |
| Operating temperature (nitrile) | −40 to +107 °C |
| Materials | Head: SG iron; bowl: forged steel |
| Bowl torque | 80 to 95 N·m |
| Weight | 20.4 kg (45 lb) |
Bypass, collapse rating and indicator on the WPF405QEBM2KY201
The bypass valve on this filter opens at 50 psid (3.5 bar), so cold start-up or a clogged element cannot starve the system of oil. The catalogue describes integral bypass and reverse flow valves in the element end cap, with every element service providing a fresh valve. A standard element of this type is rated for 300 psid collapse, in contrast to the 2000 psid of the high-collapse element used with a no-bypass filter. The bypass keeps the differential pressure well below the collapse level, which is why the two pair together.
The M2 indicator is a visual type that responds to the differential pressure across the element and shows when the element needs changing, with no electrical connection. If the control room needs a signal, other codes offer a reed-switch indicator (GS) or a 4 to 20 mA analog indicator (GA) with a DIN 43650 socket, but those are different part numbers.
Sizing notes for the WPF4
The WPF4 weighs 20.4 kg and the product page rates it at 416 l/min. The flow-loss chart in the catalogue shows how the pressure drop scales with flow for each media grade, and the 05Q grade lies between the finer 02Q and the coarser 10Q elements in both efficiency and dirt capacity. A finer element gives cleaner oil but a higher clean pressure drop and a shorter life. At a given flow the bypass valve limits the maximum drop, so the design aim is a clean differential pressure far below 50 psid and an element change when the indicator trips. For circuits with servo or proportional valves, a 5 micron or finer element is often selected.
Related parts and elements for WPF405QEBM2KY201
The matching replacement element is 941039Q. Other WPF4 elements are 941038Q (2 micron standard), 941040Q (10 micron standard), 941050Q (2 micron high collapse) and 941051Q (10 micron high collapse). Service parts for the WPF4 include the flange head 940923, the SAE-20 head 940924, the reusable core 941178, the bowl 941156, the bowl O-ring V92157 and the anti-extrusion ring 941187. The sibling WPF310QHBPXS162 is the size 3 no-bypass version with SAE-16 ports. Smaller WPF sizes 1 and 2 serve lower flows, and WPF5 serves 1-1/2 inch lines.
Selection and ordering checklist for WPF405QEBM2KY201
- Peak pressure and surge level below 414 bar.
- Flow at the working viscosity against the filter rating.
- Required cleanliness code and element grade (2, 5 or 10 micron).
- Bypass acceptable for the application; if not, choose a no-bypass version with a high-collapse element.
- Indicator type: visual (M2), electrical (GS) or analog (GA).
- Flange or thread ports and the pipe or hose connection that goes with them.
Installation and servicing of the WPF405QEBM2KY201
Mount the filter with the bowl down and leave enough clearance beneath it for the element service. Fit the visual indicator in the SAE-8 port at 40 to 45 N·m, and tighten the bowl to 80 to 95 N·m, the range the catalogue gives for the WPF4 and WPF5. The drain plug is SAE-6 and takes 35 to 40 N·m. Replace the element when the indicator shows it, or on a schedule, using element 941039Q, and inspect the bowl O-ring and anti-extrusion ring at every service. Dispose of the used element according to local oil-waste rules.
Applications in Oman and the GCC
A WPF4 with this configuration is typical for the pressure line of a large hydraulic power unit: press and forming plants, mining and tunnelling equipment, oil and gas workover and drilling hydraulics, steel mills and power plant hydraulic systems. In Oman, long service intervals and remote sites favour a filter with a visible indicator and a robust iron and steel housing, and spare elements are best kept in stock.
Information to send with an RFQ for WPF405QEBM2KY201
- Part number WPF405QEBM2KY201 and quantity, with spare elements.
- Working pressure, flow and fluid.
- Required cleanliness code.
- Pipe or flange counterparts needed.
- Delivery destination.
Documents and quotation
The Parker WPF high pressure filter catalogue with the how-to-order table, element data and parts list is attached on this page.
Seven Star LLC supplies Parker hydraulic filtration products in Oman and the GCC. Send the part number WPF405QEBM2KY201 with your quantity and we will confirm availability and quote.
Other Models in the Parker Wpf Hp Filter Range
Seven Star LLC supplies models from the Parker Wpf Hp Filter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Parker WPF310QHBPXS162 High Pressure In-Line Filter 414 bar | Filtration Systems | View details |
| Parker WPF405QEBM2KY201 High Pressure Filter WPF4 5 Micron | Filtration Systems | You are viewing this model |
| Parker WPF202QEVM2KS121 High Pressure Filter WPF2 FKM 2 Micron | Filtration Systems | View details |
Datasheets & Documents
- Catalog Parker WPF High Pressure Filter Catalogue Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker WPF405QEBM2KY201 High Pressure Filter WPF4 5
Answers from our engineering team on installation, compatibility and integration.
01What flow can the WPF405QEBM2KY201 handle?
The product page lists 110 gpm, which is 416 l/min, for this WPF4 filter. Actual pressure drop depends on viscosity and element grade, as shown in the catalogue flow-loss chart.
02At what pressure does the bypass valve open?
The K in the code is a 50 psid (3.5 bar) bypass valve, which allows oil past the element when it is cold or blocked.
03Which element does the WPF405QEBM2KY201 use?
The compatible element is 941039Q, the WPF4 5 micron standard-collapse microglass element, according to the catalogue replacement table.
04What does the M2 indicator do?
It is a 50 psi visual differential-pressure indicator with no electrical output. Reed-switch (GS) and 4 to 20 mA (GA) indicators are available as other codes.
05What pressure is the filter rated for?
The WPF series has a maximum allowable operating pressure of 6000 psi (414 bar) with a rated fatigue pressure of 6000 psi and a design safety factor of 3:1.