WPF310QHBPXS162 WPF3 high pressure in-line filter

The Parker WPF310QHBPXS162 is a size 3 WPF high pressure in-line filter for hydraulic systems that run up to 414 bar (6000 psi). It combines a ductile iron head, a forged steel bowl and a coreless, high-collapse microglass element rated at 10 microns. In this configuration there is no bypass valve, which is the safest choice for components that cannot tolerate unfiltered oil, and the indicator port is plugged. The filter belongs on the pressure line directly downstream of the pump or ahead of a servo or proportional valve. Seven Star LLC supplies the WPF310QHBPXS162 in Oman and the GCC.

How to read the model code WPF310QHBPXS162

The WPF how-to-order table is built from eight boxes. WPF is the series. The digit 3 is the size with one-inch nominal ports. 10QH is the media code: 10 micron microglass, high collapse, which is the type that must be used when no bypass is requested. B selects nitrile seals. P is a plugged indicator port, and X means no bypass and no indicator. S16 is the port, an SAE-16 thread, and the closing 2 is the option for no bypass with a high-collapse element. Neighbouring codes show how the family spreads: 02QH is a 2 micron high-collapse element, 10QE a 10 micron standard-collapse element with bypass, and K a 50 psid (3.5 bar) bypass.

WPF310QHBPXS162 technical specifications

Parameter Specification
Manufacturer / part number Parker WPF310QHBPXS162
Series / size WPF high pressure in-line filter, size 3 (1 inch nominal ports)
Element 10QH: 10 micron microglass, high collapse (2000 psid / 138 bar), coreless with reusable support core; replacement element 941049Q
Seals Nitrile (code B)
Indicator P: plugged SAE-8 indicator port; no indicator fitted
Bypass None (X); high-collapse element required
Ports SAE-16 (S16), in-line T-port head
Maximum operating pressure 414 bar (6000 psi); rated fatigue pressure 414 bar; design safety factor 3:1
Rated flow 151 l/min (40 gpm) per product page
Fluids Mineral, petroleum and PAO-based fluids
Operating temperature (nitrile) −40 to +107 °C (−40 to 225 °F)
Materials Head: SG iron; bowl: steel
Bowl torque 35 to 40 N·m
Drain SAE-6 drain plug (standard on WPF3)
Weight 9.5 kg (21 lb)

How the WPF310QHBPXS162 protects the circuit

Oil enters the head, passes through the microglass element and leaves through the outlet port. Because this version has no bypass, all flow passes through the element at any differential pressure. The element is built to withstand 2000 psid (138 bar) collapse pressure, so cold start-up or a blocked element does not collapse the media. The catalogue also notes patented deformable tangs that locate the element in the bowl, and integrated reverse flow valves in the element end cap, with SurgeGuard protection against back-flow in the design. A reusable support core stays in the bowl when the element is changed, which is why the element is called coreless.

Choosing no bypass is a deliberate trade-off. A filter without bypass never lets dirty oil through, but a neglected element can restrict flow or push the pump relief to open, so service intervals must be planned by hours or by differential-pressure monitoring elsewhere in the circuit.

Sizing the WPF3 for your system

The product page lists 151 l/min (40 gpm) as the flow of the WPF3. Pressure drop depends on the media, viscosity and flow; the catalogue gives flow-loss curves for each size and notes that the high-collapse “QH” elements have a loss 1.4 times the reported value of the standard element. Plan for a clean pressure drop well below the pump relief setting, and size the filter so the element does not operate at its maximum rated flow continuously. Fluid compatibility covers mineral, petroleum and polyalphaolefin fluids with nitrile seals, and the catalogue gives an alternative seal range for ethylene propylene and fluorocarbon versions through other codes.

Related WPF parts and elements for WPF310QHBPXS162

The catalogue lists the replacement element for this exact configuration as 941049Q. Other WPF3 elements are 941035Q (2 micron standard), 941036Q (5 micron standard), 941037Q (10 micron standard) and 941048Q (2 micron high collapse). Service parts for the WPF3 include the SAE-16 head 940991, the one-inch flange head 940992, the reusable core 941177, the bowl 945767 and the FKM seal kit 947535, while the SAE-8 indicator plug is 941172. The same series spans WPF1 with half-inch ports up to WPF5 with 1 1/2 inch ports and a weight of 30.4 kg. Other filter families from the same range, such as the 100P, 28P and 70 series high pressure in-line filters, cover different pressures and sizes.

Selection and ordering checklist for WPF310QHBPXS162

  • Maximum system pressure: below 414 bar including surges.
  • Fluid and temperature compatibility with nitrile seals; request another seal code if the fluid needs it.
  • Required cleanliness and filtration ratio: 10 micron here; select 2 or 5 micron for servo systems.
  • Bypass or no bypass: confirm that your design allows an unbypassed filter.
  • Port type: SAE-16 here, with flange and manifold options in the family.
  • Indicator needs: an indicator can be selected in other codes but is not available with the no-bypass option.

Installation, commissioning and maintenance of the WPF310QHBPXS162

Mount the filter vertically with the bowl down and enough space below to remove the bowl and element. Torque the bowl to 35 to 40 N·m, the drain plug to the same range, and the indicator or its plug to 40 to 45 N·m. Change the element on a time basis or when a downstream differential-pressure signal rises, whichever comes first, and replace it with the matching element number 941049Q. Take an oil sample after the first hours of operation to confirm the cleanliness target. Whenever an element is serviced, inspect the bowl O-ring and the head seat, and fit a seal kit when they are hardened or damaged.

Applications in Oman and the GCC

The catalogue lists oil and gas exploration, power generation, primary metals, mining and injection moulding among the typical applications for the WPF series. In Oman and the Gulf that means high pressure circuits on drilling and workover equipment, hydraulic power units for valve actuators, steel and aluminium plants, and presses. Dust, heat and long maintenance intervals make the choice of a high-collapse, high-pressure rated housing attractive.

Information to send with an RFQ for WPF310QHBPXS162

  • Part number WPF310QHBPXS162 and quantity, including spare elements.
  • Working pressure, flow and fluid type.
  • Required cleanliness code.
  • Port connection and mounting position.
  • Delivery destination.

Documents and quotation

The Parker WPF high pressure filter catalogue with the how-to-order table, element data and parts list is attached on this page.

Seven Star LLC supplies Parker hydraulic filtration products in Oman and the GCC. Send the part number WPF310QHBPXS162 with your quantity and we will confirm availability and quote.

Other Models in the Parker Wpf Hp Filter Range

Seven Star LLC supplies models from the Parker Wpf Hp Filter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Parker WPF310QHBPXS162 High Pressure In-Line Filter 414 barFiltration SystemsYou are viewing this model
Parker WPF405QEBM2KY201 High Pressure Filter WPF4 5 MicronFiltration SystemsView details
Parker WPF202QEVM2KS121 High Pressure Filter WPF2 FKM 2 MicronFiltration SystemsView details
Datasheets & Documents
  • PDF Catalog Parker WPF High Pressure Filter Catalogue Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker WPF310QHBPXS162 High Pressure In-Line Filter

Answers from our engineering team on installation, compatibility and integration.

01What pressure is the WPF310QHBPXS162 rated for?
The WPF series has a maximum allowable operating pressure of 6000 psi (414 bar), with a rated fatigue pressure of 6000 psi and a design safety factor of 3:1.
02Does this filter have a bypass valve?
No. The X in the code means no bypass and no indicator, and a high-collapse element rated for 2000 psid (138 bar) must be used with that option.
03Which element fits the WPF310QHBPXS162?
The replacement element is 941049Q, the size 3, 10 micron high-collapse microglass element listed in the catalogue.
04What port size does it have?
S16 is an SAE-16 port in the in-line T-port head, with one inch nominal port size on the WPF3.
05What fluids can it handle?
The product page lists mineral, petroleum and polyalphaolefin fluids with nitrile seals, operating from minus 40 to 107 degrees Celsius according to the catalogue.