Brand:

Parker 70T310QHBM3NG202 High Pressure In-Line Filter 420 bar

Description

70T310QHBM3NG202 70 series T-port filter without bypass

The Parker 70T310QHBM3NG202 is a high pressure in-line filter from the 70/70 Eco series, a robust cast iron and steel design that Parker rates for 420 bar. It is the T-port version (70T), in length 3, with a 10 micron high-collapse Microglass III element, nitrile seals, a visual indicator and G 1-1/4 threaded ports. There is no bypass valve, which makes it suitable for lines that must never pass unfiltered oil, such as the supply to servo and proportional valves. Seven Star LLC supplies the 70T310QHBM3NG202 in Oman and the GCC.

Reading the model code 70T310QHBM3NG202

The catalogue product configurator uses eight boxes. 70T is the model, a high pressure filter with a T-port head, and 3 is the bowl length. 10QH is the media: 10 micron Microglass III in a high-collapse element. B is nitrile, and M3 is the visual indicator. N is the bypass and indicator setting for no bypass and a 7.0 bar indicator, and it is paired with option 2 in the final box, no bypass. G20 is the thread G 1-1/4 connection. The catalogue states that when a filter has no bypass, a high collapse element must be used, because a standard element is rated for only 20 bar collapse and the high-collapse element for 210 bar.

70T310QHBM3NG202 technical specifications

Parameter Specification
Manufacturer / part number Parker 70T310QHBM3NG202
Series / model 70 Series high pressure filter, T-port head (70T), length 3
Element 10QH: 10 micron Microglass III, high collapse (210 bar collapse rating); replacement element 938813Q
Seals Nitrile (code B)
Indicator M3: visual, 7.0 bar setting (for no-bypass filters)
Bypass None (code N with option 2)
Connection G20: thread G 1-1/4 (ISO 228/1)
Maximum operating pressure 420 bar (350 bar for length 4); housing pulse-fatigue tested at 0 to 414 bar, 10^6 pulses
Nominal flow 280 l/min at 30 cSt (length 3, 10 micron, G20 T-port)
Operating temperature (nitrile) −40 to +100 °C
Materials Head: cast iron (GSI); bowl: steel, maximum torque 40 Nm
Fluids Mineral and vegetable oils and some synthetic oils
Weight 19 kg (70T, length 3)

Why the 7.0 bar visual indicator and no bypass go together

The catalogue gives two indicator setpoints: 2.5 bar for filters with a 3.5 bar bypass valve and 7.0 bar for filters without bypass. With no bypass the filter can build much more differential pressure before the element is loaded, so the indicator is set higher and the 210 bar collapse rating of the high-collapse element gives the margin to survive it. The M3 visual indicator shows the condition at a glance, and for remote monitoring the same family offers T1 electrical and F1 to F4 electronic types. The catalogue adds that, with a visual or other indicator selected, the right-hand port in the flow direction is plugged with a plastic plug and the left with a steel plug.

Sizing the 70T length 3 filter

Nominal flow for this length with the 10 micron element is listed in the catalogue as 280 l/min for the G20 T-port. The table shows that the finer 2 and 5 micron elements pass less flow, 220 and 250 l/min for the Q grade in length 3 with G20, and the 20 micron grade more at 300 l/min. Higher flows are possible with G24 ports. Because pressure drop depends on viscosity, the catalogue estimates the total as the housing drop plus the element drop multiplied by working viscosity over 30 cSt, so cold oil reduces the usable flow. High-collapse elements have a different pressure-drop curve from standard ones, which the catalogue shows on separate charts. The product page for this part lists a different flow range, so please use the catalogue figure for sizing and confirm the duty point with us.

Related parts to 70T310QHBM3NG202

The matching element for 10QH in length 3 is 938813Q. Other length 3 high-collapse elements are 938811Q (2 micron), 938812Q (5 micron) and 938814Q (20 micron). Standard Microglass III elements with a bypass filter are 938779Q to 938782Q, and Ecoglass III elements 938795Q to 938798Q. The 70 series also comes as an L-port (70L) and a side-manifold type (70B), in lengths 1 to 4, with weights between 10.5 and 22 kg. The EPF iprotect family, for example the EPF4105QIHBT1MH202, is the newer Parker line for similar duties.

Selection and ordering checklist for 70T310QHBM3NG202

  • Operating pressure within 420 bar, or 350 bar if you move to length 4.
  • Flow at working viscosity against the catalogue table.
  • Cleanliness target, for example 10 micron here or 2 and 5 micron for servo systems.
  • No-bypass design acceptable, with high-collapse element and an alarm strategy.
  • Indicator type and wiring.
  • Port: G thread, SAE flange or side manifold on the 70B.

Installation and servicing of the 70T310QHBM3NG202

Install the filter vertically with the bowl down, leaving enough clearance to pull the bowl and element. The catalogue gives a maximum torque of 40 Nm for the bowl. Connect the inlet and outlet according to the flow arrow on the head. Plug unused indicator ports as supplied. Replace the element with 938813Q when the indicator shows, and always inspect the seals before closing the bowl. Because there is no bypass, do not delay service: a blocked element restricts flow to the downstream components.

Applications in Oman and the GCC

The catalogue names industrial power units, port handling equipment, mining and quarrying equipment, forestry equipment and pulp and paper among typical applications. In Oman that matches container and bulk handling at ports, quarry and crusher hydraulics, and power units on industrial plants. Dust and heat favour a sealed iron and steel housing, and fine filtration ahead of valves reduces wear.

Information to send with an RFQ for 70T310QHBM3NG202

  • Part number 70T310QHBM3NG202 and quantity, with spare elements.
  • Working pressure, flow and fluid.
  • Cleanliness target.
  • Indicator or alarm requirements.
  • Delivery destination.

Documents and quotation

The Parker 70/70 Eco series catalogue with the product configurator, element table and dimensions is attached on this page.

Seven Star LLC supplies Parker hydraulic filtration products in Oman and the GCC. Send the part number 70T310QHBM3NG202 with your quantity and we will confirm availability and quote.

Datasheets & Documents
  • PDF Catalog Parker 70/70 Eco Series High Pressure Filter Catalogue Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker 70T310QHBM3NG202 High Pressure In-Line

Answers from our engineering team on installation, compatibility and integration.

01Does the 70T310QHBM3NG202 have a bypass valve?
No. Code N with option 2 means no bypass. The catalogue requires a high-collapse element with 210 bar collapse rating in that case, which is the 10QH element used here.
02What indicator does the filter use?
The M3 visual indicator with a 7.0 bar setting, the value the catalogue assigns to filters without bypass. Electrical and electronic indicators are other codes.
03Which element fits the 70T310QHBM3NG202?
The catalogue lists 938813Q as the 10QH high-collapse element for the 70T length 3 filter.
04What is the maximum working pressure?
The catalogue gives 420 bar maximum allowable operating pressure, 350 bar for length 4, with the housing pulse-fatigue tested for one million cycles from 0 to 414 bar.
05What thread does the G20 connection have?
G20 is a G 1-1/4 thread to ISO 228/1. Other connections are G16, G24 and SAE flange codes, depending on the length.