Brand: Parker
Parker WPF202QEVM2KS121 High Pressure Filter WPF2 FKM 2 Micron
Description
WPF202QEVM2KS121 WPF2 filter with 2 micron element and fluorocarbon seals
The Parker WPF202QEVM2KS121 is a compact size 2 high pressure in-line filter from the WPF series. It combines the finest standard element grade, a 2 micron microglass element, with fluorocarbon seals, a 50 psid bypass and a visual indicator, in a body with SAE-12 ports. The product page quotes 94.6 l/min (25 gpm), and the filter is rated for 414 bar. The fine grade and the heat-resistant seals make it a fit for servo and proportional valve circuits and for hot oil, where the standard 10 micron nitrile filter would not do. Seven Star LLC supplies the WPF202QEVM2KS121 in Oman and the GCC.
Reading the part number WPF202QEVM2KS121
WPF is the series and 2 is the size with 3/4 inch nominal ports. 02QE is the media code for 2 micron standard-collapse microglass. V is fluorocarbon seals, M2 is the 50 psi visual indicator and K is the 50 psid (3.5 bar) bypass. S12 is an SAE-12 port, and the final 1 is the option for a bypass filter with a standard element. Replace the V with B and the seals become nitrile, and with E they become ethylene propylene, according to the box 4 table. Because the indicator is fitted as a loose part, it is installed on site.
WPF202QEVM2KS121 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker WPF202QEVM2KS121 |
| Series / size | WPF high pressure in-line filter, size 2 (3/4 inch nominal ports) |
| Element | 02QE: 2 micron microglass, standard collapse (300 psid / 21 bar), coreless; replacement element 941032Q |
| Bypass | K: 50 psid (3.5 bar) bypass valve, option 1 |
| Indicator | M2: 50 psi visual indicator |
| Seals | Fluorocarbon (code V) |
| Ports | S12: SAE-12 thread |
| Maximum operating pressure | 414 bar (6000 psi); rated fatigue pressure 414 bar; design safety factor 3:1 |
| Rated flow | 94.6 l/min (25 gpm) per product page |
| Fluids | Mineral, petroleum and PAO-based fluids |
| Operating temperature (fluorocarbon) | −26 to +135 °C (−15 to 275 °F) |
| Materials | Head: SG iron; bowl: forged steel |
| Bowl torque | 35 to 40 N·m |
| Weight | 5.9 kg (13 lb) |
Why a 2 micron element and FKM seals
Servo valves, proportional valves and piston pumps tolerate far less contamination than gear pumps and directional valves, so ISO cleanliness targets are tighter and a 2 micron element becomes the natural choice. The catalogue efficiency chart shows that the finer grades hold a high beta ratio at small particle sizes, while the dirt capacity is lower than that of the coarser grades, so elements are replaced more often unless the system is already clean. Fluorocarbon seals extend the operating range to 135 °C, compared with 107 °C for nitrile and ethylene propylene. They are also used when the fluid is incompatible with nitrile; confirm the fluid with the supplier of the oil.
The 50 psid bypass protects the system from oil starvation when the element clogs or the oil is cold. Fine media creates more restriction when cold, so the bypass may open during start-up in cool conditions, which is a reason to size the filter generously for the flow.
Related parts for WPF202QEVM2KS121
The replacement element is 941032Q. Other WPF2 elements are 941033Q (5 micron) and 941034Q (10 micron) in standard collapse, and 941046Q (2 micron) and 941047Q (10 micron) in high collapse for no-bypass filters. Service parts include the SAE-12 head 940988, the 3/4 inch flange head 940989, the reusable core 941176, the bowl 942299, the bowl O-ring V92144 and the anti-extrusion ring 934798. Larger siblings include the WPF310QHBPXS162 and the WPF405QEBM2KY201 on this site.
Selection checklist for WPF202QEVM2KS121
- Required ISO cleanliness class of the protected components and whether 2 micron is needed.
- Flow at the working viscosity: up to 94.6 l/min for this size.
- Fluid and temperature compatibility with fluorocarbon seals.
- Pressure rating of 414 bar versus system peaks.
- Port size SAE-12 or the flange and manifold alternatives in the family.
- Indicator type and whether a bypass is acceptable.
Installation and service of the WPF202QEVM2KS121
Install the filter in the pressure line with the bowl pointing down and space to remove it. Tighten the bowl to 35 to 40 N·m. The drain plug is SAE-6 at 35 to 40 N·m and the SAE-8 indicator port takes 40 to 45 N·m. Change the element when the indicator shows or at the planned interval, replacing the bowl O-ring if it is damaged. A flushing procedure with the filter in place speeds up the cleaning of new hydraulic systems; replace the element after flushing, because the first fill carries the most dirt.
Applications in Oman and the GCC
A 2 micron FKM WPF2 is suited to servo and proportional circuits on presses and test benches, to compact power units for valve actuators and turbine controls, and to hot-oil circuits in refineries and power plants. In Oman and the Gulf the combination of high ambient temperature and fine filtration is typical, so the filter should be paired with a good breather on the tank to keep airborne dust out of the oil.
Information to send with an RFQ for WPF202QEVM2KS121
- Part number WPF202QEVM2KS121 and quantity, including spare elements.
- System pressure, flow, fluid and temperature.
- Cleanliness target.
- Port connection details.
- Delivery destination.
Storage, handling and spares for the Parker WPF202QEVM2KS121
Keep Parker WPF202QEVM2KS121 elements sealed in their original bags and boxes until installation. Store them flat or upright as marked on the carton, indoors, away from dust, moisture, solvents and direct sun. In hot warehouses in Oman and the GCC, check that seals and gaskets are not stored above the temperature limits given by the manufacturer.
- Check the part number, micron rating and seal material on every element against the housing data plate before fitting.
- Replace elements when the differential pressure indicator or the site maintenance schedule calls for it, not only when flow drops.
- Fit new O-rings or gaskets with each element change where the instructions require it.
- Keep at least one spare element for each housing in service, so that a change-out does not wait for a shipment.
When you send an RFQ for the Parker WPF202QEVM2KS121, list the housing model, required micron rating, media and quantity of spare elements, so the complete filtration scope can be quoted together.
Documents and quotation
The Parker WPF high pressure filter catalogue with the how-to-order table, element data and parts list is attached on this page.
Seven Star LLC supplies Parker hydraulic filtration products in Oman and the GCC. Send the part number WPF202QEVM2KS121 with your quantity and we will confirm availability and quote.
Other Models in the Parker Wpf Hp Filter Range
Seven Star LLC supplies models from the Parker Wpf Hp Filter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Parker WPF310QHBPXS162 High Pressure In-Line Filter 414 bar | Filtration Systems | View details |
| Parker WPF405QEBM2KY201 High Pressure Filter WPF4 5 Micron | Filtration Systems | View details |
| Parker WPF202QEVM2KS121 High Pressure Filter WPF2 FKM 2 Micron | Filtration Systems | You are viewing this model |
Datasheets & Documents
- Catalog Parker WPF High Pressure Filter Catalogue Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker WPF202QEVM2KS121 High Pressure Filter WPF2
Answers from our engineering team on installation, compatibility and integration.
01What flow is the WPF202QEVM2KS121 rated for?
The product page gives 25 gpm, equal to 94.6 l/min. The catalogue flow-loss curves show the pressure drop for each media grade and viscosity.
02What does the V in the code mean?
V is the box 4 seal code for fluorocarbon. B is nitrile and E is ethylene propylene in the same table. Fluorocarbon covers minus 26 to plus 135 degrees Celsius.
03Which replacement element fits the WPF202QEVM2KS121?
The compatible element is 941032Q, the WPF2 2 micron standard-collapse microglass element.
04Does the filter have a bypass valve?
Yes. The K in the code is a 50 psid (3.5 bar) bypass valve, together with a 50 psi visual indicator M2 that is shipped as a loose part.
05What pressure rating does the WPF2 have?
The WPF series is rated for 6000 psi (414 bar) maximum allowable operating pressure with a design safety factor of 3:1.