Brand: Hach
Hach 9184 sc Amperometric Free Chlorine Sensor System
Description
Hach 9184 sc amperometric free chlorine sensor system for 0 to 20 mg/L residual chlorine
The Hach 9184 sc is an amperometric free chlorine analyzer that measures hypochlorous acid (HOCl) through a membrane electrode and, together with pH and temperature, calculates total free chlorine (TFC). It is delivered as a pre-assembled panel with a flow cell and the sensors, and it connects to a Hach sc digital controller. Because it uses a membrane system, the manufacturer states that no reagents are needed for the measurement. Seven Star LLC supplies the 9184 sc in Oman and the GCC as an independent supplier in Muscat, and this page explains the measurement principle, options and ordering points.
How the 9184 sc measures free chlorine
The measuring cell contains a gold cathode and a silver anode behind a membrane with electrolyte. Hypochlorous acid diffuses through the membrane and is reduced at the cathode, which produces a current proportional to its concentration. The standard 9184 sc sensor measures HOCl, temperature and pH, then uses dissociation curves stored in the instrument to calculate hypochlorite ions (OCl-); HOCl plus OCl- equals total free chlorine. The data sheet notes that there is no interference from chloramines, whereas chlorine dioxide and ozone do interfere. Free chlorine is the quantity that actually disinfects, so the sensor suits residual monitoring where chloramine would give a false high reading in a total-chlorine test.
Technical specifications of the 9184 sc
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Hach / 9184 sc (order number LXV432.99.00001) |
| Measurement technology | Amperometric, membrane (electrode, membrane, electrolyte) |
| Measurement range | 0 … 20 mg/L (ppm) as HOCl |
| Minimum detection limit | 5 µg/L (0.005 mg/L) HOCl |
| Accuracy | 2 % or ±10 µg/L TFC, whichever is greater, at pH below 7.5; same for HOCl below pH 8 |
| Standard deviation | 0.7 % |
| Response time | 90 % in less than 90 seconds |
| Measurement interval | Continuous |
| Minimum flow rate | 14 L/h (200 … 250 mL/min), auto-regulated by the flow-through cell |
| Pressure range | 0.1 … 2 bar in the flow cell |
| Sample pH | 4 … 8 (acidification unit available for pH above 8) |
| Sample temperature | 2 … 45 °C with automatic temperature compensation |
| Operating temperature / humidity | 0 … 45 °C / 0 … 90 % non-condensing |
| Power | 12 V, 1.5 W, supplied by the controller |
| Calibration interval | 2 months |
| Maintenance interval | Measurement cell: membrane and electrolyte about 6 months; pH cell about 1 to 1.5 years |
| Materials | Gold cathode, silver anode; acrylic measuring cell; PVC probe body |
| Environmental rating | IP66 / NEMA 4X |
| Connections | Sample line 1/4 in OD; drain line 1/2 in ID (supplied) |
| Dimensions / shipping weight | 270 x 250 mm / 6.5 kg |
| Certifications | UL, CSA (certified by ETL), CE |
Options: acidification, intermittent flow and HOCl-only
- Acidification Unit: keeps accuracy at 2 percent when the sample pH is above 7.5, by forcing the sample pH to between 5.5 and 6.5. It can also inject cleaning solution through the cell, always on or programmed through controller relays. It has a power switch and is NEMA 4X/IP66 compliant.
- Intermittent Flow Unit: programmable through controller relays, it limits sample flow to drain to save water. It connects in series with the analyzer and also needs one controller input.
- HOCl-only version: a sensor that does not compensate for pH, intended for applications where the pH does not fluctuate; the data sheet says it is available only after consultation with technical support.
Calibration, maintenance and consumables
Zero calibration can be done electrically, which is automatic, or with dechlorinated water. Span calibration compares the sensor with a laboratory method on a process sample. The pH cell is calibrated with single- or two-point standards or by comparison with a laboratory method. The manufacturer suggests a calibration interval of two months, a membrane and electrolyte change every six months in typical use and a pH cell replacement every one to one and a half years. Two years of typical maintenance items are included with the system. A fouled or pinched sample line, air in the flow cell or a pH above the compensation limit are the commonest reasons for unstable readings.
Selection and ordering checklist for the 9184 sc
- Sample pH: choose the Acidification Unit if the pH regularly exceeds 7.5.
- Presence of ozone or chlorine dioxide, which interfere with the measurement.
- Sample temperature and pressure within 2 to 45 °C and 0.1 to 2 bar in the flow cell.
- Water consumption limits: consider the Intermittent Flow Unit.
- Controller: SC4500, sc200 or sc1000 with the necessary outputs; controllers accept two to eight sensors.
- Spare membranes, electrolyte and pH cell.
Installation
Mount the pre-assembled panel on a flat, vertical surface close to the sampling point. Provide a clean, representative sample at a stable flow, connect the sample line to the 1/4 inch fitting and run the 1/2 inch drain line to a safe point. Plug the sensor into the controller; as a digital sc sensor it needs no complex wiring. Allow the sensor to polarise and stabilise before calibration, then verify against a lab test of the same sample. Protect the panel from direct sun and heat, since the operating range is 0 to 45 °C.
Typical applications in Oman and the GCC
Typical uses are residual chlorine monitoring in drinking water distribution and storage, chlorination control after desalination and remineralisation, cooling water and industrial water disinfection, and effluent checks before discharge or reuse. The manufacturer lists drinking water, wastewater, pure water and power, and industrial water as markets. Chlorine dosing in a hot climate decays quickly in storage, so continuous measurement helps keep a residual at the required level without overdosing.
Information to send with an RFQ for the 9184 sc
- Model: 9184 sc with options (acidification, intermittent flow)
- Sample pH, temperature and flow
- Controller model and outputs
- Spares for the first two years
- Quantity and delivery site
Documents and quotation
The Hach 9184 sc data sheet is attached on this page. It contains the specification table, the options and the principle of operation.
Send the application data and Seven Star LLC will confirm availability and prepare a quotation.
Datasheets & Documents
- Datasheet Hach 9184 sc Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hach is the American specialist in water quality analysis: spectrophotometers and reagents, laboratory meters, online analysers for chlorine, turbidity, nutrients and dissolved oxygen, and controllers. Clifford and Kathryn (Kitty) Hach founded the company in 1947 in Ames, Iowa, with USD 15,000 that Clifford had earned from a patent, and their first success was a simplified titration test for water hardness. Hach moved its headquarters to Loveland, Colorado, in 1978, was acquired by Danaher in 1999, and is now part of Veralto.
Seven Star LLC lists Hach online analyzers, controllers, sensors, portable meters and reagents, and sources them for water, wastewater, power and process plants in Oman.
Hach company profile
| Founded | 1947, Ames, Iowa, USA |
|---|---|
| Founders | Clifford C. Hach (chemist) and Kathryn "Kitty" Hach (sales, marketing and operations) |
| Headquarters | Loveland, Colorado, USA (since 1978); reagent manufacturing remains in Ames |
| Ownership | Public from 1968; Danaher from 1999; part of Veralto (NYSE: VLTO) since the 2023 separation from Danaher |
| Product families | DR series spectrophotometers and test reagents, HQ and sensION meters, SC controllers, online chlorine, turbidity, nutrient, oxygen and TOC analysers, samplers |
Milestones
- 1947: Clifford and Kitty Hach start the company in Ames, Iowa.
- 1968: Hach becomes a public company.
- 1978: Headquarters move to Loveland, Colorado.
- 1999: Danaher acquires Hach.
- 2004: Hach combines with Dr. Bruno Lange GmbH of Germany.
- 2023: Hach becomes part of Veralto, separated from Danaher.
Hach analyzers, sensors and reagents listed
The Hach products on this page fall into four main groups, plus a few accessories such as a colorimeter, a reagent dispenser, a power supply and a flow control valve:
- Online analyzers: CL17sc colorimetric chlorine analyzer, TU5300sc and TU5400sc laser turbidimeters, BioTector B3500ul TOC analyzer, Polymetron 9245 sodium analyzer and Orbisphere 510 dissolved gas analyzer
- Controllers and digital sensors: SC4500 controller and the LDO 2 luminescent dissolved oxygen sensor
- Portable and laboratory instruments: 2100Q turbidimeter, HQ4200 multi-parameter meter and IntelliCAL probes such as the LBOD101
- Reagents: DPD free chlorine powder pillows and DEHA reagents for oxygen scavenger testing
Polymetron and Orbisphere analyzers are aimed at power plant water-steam cycles and similar pure water duties, where sodium, dissolved oxygen and other gases are measured at low levels.
Where Hach instruments are used
Hach instruments appear in drinking water plants, desalination, sewage treatment, cooling and boiler water circuits, and industrial effluent monitoring across the GCC. Operators use the portable meters and reagents for spot checks, and the sc analyzers and probes for continuous signals to the control system.
Hach products we list
Ordering Hach products: what we need
Hach identifies every item by a catalog number, for example LXV416.99.20001 for a sensor or 21055-69 for a reagent pack, and the same reagent may be written with or without the dash. Send that number and the quantity. For analyzers and controllers, add the parameter and range, sample conditions, power supply, outputs and communication option. For sensors, tell us the controller model they will connect to and the cable length. For reagents, name the instrument and method so pack size and range can be confirmed against Hach documentation.
Facts checked against Hach's published company history, October 2026.
Browse Hach products by category: Liquid Analytical Accessories, Liquid Analysis Sensors, Portable Test & Measurement, Liquid Analytical Systems.
FAQ
Questions about the Hach 9184 sc Amperometric Free Chlorine Sensor
Answers from our engineering team on installation, compatibility and integration.
01What does the Hach 9184 sc measure?
It measures hypochlorous acid with an amperometric membrane sensor and calculates total free chlorine using pH and temperature, over a range of 0 to 20 mg/L.
02Does chloramine interfere?
The data sheet states no interference from chloramines. Chlorine dioxide and ozone do interfere with the measurement.
03When is the acidification unit needed?
It is used to keep 2 percent accuracy when the sample pH is above 7.5, by adjusting the sample pH to between 5.5 and 6.5.
04Does it need reagents?
No reagents are used for the measurement because it is a membrane system. The membrane and electrolyte are replaced about every six months.
05Which controllers does it connect to?
It connects to Hach sc digital controllers, which accept two to eight sensors, with plug-and-play connection.