Brand:

SICK FTMG-ISN50SXX FTMg Thermal Mass Flow Sensor

Description

FTMG-ISN50SXX, part no. 1122525, is a SICK FTMg compressed-air flow meter with an integrated measuring channel that records flow, temperature and pressure. The catalogue summary lists: nominal width measuring tube: DN 50; process connection: 2” NPT male thread; connection type: M12 x 1 round connector, 5-pin, A-coded; housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301; communication interface: IO-Link.

What the FTMG-ISN50SXX does in a machine

Compressed-air systems are typically assessed in these terms, to find leaks and to allocate costs to production lines. The interface depends on the version.

The standard and the extended measuring ranges differ in accuracy. The medium specification is part of the data: compressed air to a stated quality class, and argon, nitrogen or carbon dioxide.

Technical specifications

Parameter Specification
Type code FTMG-ISN50SXX
Part number 1122525
Product family FTMg
Measurement principle Calorimetric (flow, temperature), piezoresistive (pressure)
Medium Compressed air (air quality ISO 8573-1:2010 [3:4:4]), Argon, nitrogen, carbon dioxide
Measured values Mass, volume, Mass flow rate, Volumetric flow rate, Energy, Flow velocity, pressure, Temperature
Nominal width measuring tube DN 50
Measuring range: Standard 58.9 l/min … 11,780.9 l/min
Measuring range: Enhanced 11,780.9 l/min … 17,671.5 l/min
Process temperature –20 °C … +60 °C
Process pressure 0 bar … 16 bar
Communication interface IO-Link, IO-Link V1.1
Temperature measurement Yes
Pressure measurement Yes
Maximum flow ≤ 17,672 l/min
Measurement accuracy: Standard ± 6 % of the measured value + 0.6% of the measuring range limit value (extended measuring range)
Measurement accuracy: Enhanced ± 8 % of the measured value + 1% of the measuring range limit value (extended measuring range)
Response time < 0.3 s
Temperature measurement: Measurement accuracy (temperature) ± 2 °C
Temperature measurement: Repeatability (temperature) ± 0.5 °C
Pressure measurement: Measurement accuracy (pressure) ± 1.5 % of measuring range end value
Pressure measurement: Non-linearity (pressure) ± 0.5 % from measuring range
Pressure measurement: Repeatability (pressure) ± 0.2 % from measuring range
Supply voltage 17 V DC … 30 V DC
Power consumption < 4.5 W at 24 V DC without output load
Switch-on time ≤ 10 s
Connection type M12 x 1 round connector, 5-pin, A-coded
Output load 4 mA … 20 mA, max. 500 ohm
Lower signal level 3.5 mA … 3.8 mA
Upper signal level 20.5 mA … 21.5 mA
Declarations and certificates in the data sheet EU declaration of conformity; UK declaration of conformity; ACMA declaration of conformity; Moroccan declaration of conformity; China RoHS; China Compulsory Product Certification (CCC) exempt; cULus certificate; IO-Link certificate; Information according to Art. 3 of Data Act (Regulation EU 2023/2854)

Ordering FTMG-ISN50SXX: type code, part number and fit

Wiring data to note: range: 58.9 l/min … 11,780.9 l/min; power draw: < 4.5 W at 24 V DC without output load; response time: < 0.3 s; supply: 17 V DC … 30 V DC; connection: M12 x 1 round connector, 5-pin, A-coded; interface: IO-Link, IO-Link V1.1.

Housing and environmental limits listed: enclosure rating IP65 (IEC 60529); IP67 (IEC 60529); weight approx. 2.8 kg; operating temperature –20 °C … +60 °C; housing PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301.

Before ordering, confirm the nominal width and the process connection thread, the measuring range for your consumption, the medium and its quality, and the communication interface your network supports.

Check the pressure and temperature range and the wetted materials against the system, and make sure the interface and supply listed in the table, whether Ethernet with PoE or IO-Link with 24 V, are available at the mounting position.

Related SICK products: SICK SW50 High-Temperature Glass Reflector, SICK IME18-05BPSZC0S Inductive Sensor, SICK IQ40-40NPSKC0S IQG Inductive Proximity Sensor, SICK KTS-WB9114114IZZZZ KTS Contrast Sensor, SICK TiM571-2050101 TiM 2D Lidar Sensor and SICK LMS511-10100 PRO LMS5xx 2D Lidar Sensor.

Documents and quotation

Use the attached SICK data sheet (FTMG-ISN50SXX, part no. 1122525) to check wiring, mounting and approvals. To request a quotation, submit the part number with quantity and destination in the RFQ form; Seven Star LLC is an independent supplier based in Muscat. Related SICK items are listed under Flowmeters. Check wiring, mounting and approvals against the data sheet before you order, since the data sheet is the governing document.

Datasheets & Documents
  • PDF Datasheet SICK FTMG-ISN50SXX official data sheet (part no. 1122525) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.

SICK company profile

Founded 1946, Munich, Germany, by Erwin Sick (1909–1988)
Headquarters Waldkirch, Baden-Württemberg, Germany (since 1956)
Ownership Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996
Size More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023)
First breakthrough Accident-prevention light curtain for presses, shown in Hanover in 1952
International growth First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide
Product families Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring

Milestones

  • 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
  • 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
  • 1956: The company moves to Waldkirch with 25 employees.
  • 1972 and 1976: Subsidiaries are founded in France and the United States.
  • 1996: SICK becomes an Aktiengesellschaft.
  • Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.

Choosing a SICK sensor

For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.

Where SICK products are used

In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.

SICK products we list

Family Examples
Photoelectric sensors WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link
Proximity, cylinder and ultrasonic sensors IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork
Machine safety nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD
Encoders and motor feedback DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50
Distance sensors and code readers DT50, DL50, DT35, Lector632

Ordering SICK products: what we need

Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.

Frequently requested SICK models: SICK RT-P3231 ZoneControl Background Suppression Sensor.

Facts checked against SICK's published company history and annual figures, October 2026.

FAQ

Questions about the SICK FTMG-ISN50SXX FTMg Thermal Mass Flow Sensor

Answers from our engineering team on installation, compatibility and integration.

01What is the SICK FTMG-ISN50SXX?
It is a SICK thermal mass flow sensor (FTMg), part no. 1122525. The catalogue summary reads: Nominal width measuring tube: DN 50; Process connection: 2” NPT male thread; Connection type: M12 x 1 round connector, 5-pin, A-coded; Housing material: PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301.
02Which supply voltage applies to the FTMG-ISN50SXX?
Supply voltage is 17 V DC ... 30 V DC. Check the output and interface rows in the table for the signal levels.
03What protection rating and temperature range are given?
Enclosure rating: IP65 (IEC 60529) ; IP67 (IEC 60529). Ambient operating temperature: –20 °C ... +60 °C. Confirm both against the site before ordering.
04Does the page include the data sheet?
Yes. The official SICK data sheet for part no. 1122525 is attached as a PDF and linked on this page; where it differs from the page text, the data sheet applies.
05What should be confirmed before ordering the FTMG-ISN50SXX?
Compare the full type code and part number 1122525 with the device being replaced, check supply, output or interface and mounting, and send the details through the RFQ form. Seven Star LLC is an independent supplier, not a SICK partner.