Schneider Electric ZB2BE101 ZB2 Contact Block, 1 NO

Description

ZB2BE101: 1 NO contact block for XB4 and XB5 style stations

The ZB2BE101 is a Schneider Electric Harmony XAC contact block of the ZB2 family, carrying a single NO (1 NO) contact on terminals 13-14. It mounts at the front of its operator and is designed for spring-return operators, so the contact follows the button: the contact closes on press and opens on release. Seven Star LLC supplies the ZB2BE101 in Oman and the GCC as an independent supplier in Muscat, often for panel builders who are renewing worn contacts on control stations that have to stay in service.

The datasheet title is only the words CONTACT BLOCK, so the part number is the reliable identifier. Its digit code is not explained on the datasheet, and the contact action of ZB2BE101 is confirmed by the Contacts type and composition entry (1 NO) and by the ISO terminal marking (13-14)NO. The sibling with the opposite action is ZB2BE102.

Environmental data for the ZB2BE101

The block is rated for -25 to 70 °C in service and -40 to 70 °C in storage, with vibration resistance of 15 gn from 10 to 500 Hz and electric shock protection class II. The listed standards are IEC 60947-5-1, IEC 60204-32, UL 508 and CSA C22.2 No 14. No IP rating or product certification line is given on this datasheet for the block alone, so ingress protection depends on the operator and enclosure that surround it.

In a hot climate the practical limit is the temperature inside the enclosure, not the outdoor ambient. A cabinet in direct sun can run far above the air temperature, so measure or estimate it before relying on the upper limit, and keep contact blocks away from heat sources such as braking resistors and power supplies.

Fitting and wiring the ZB2BE101

Terminals are screw clamps accepting one conductor of 2.5 mm² or two conductors of 1.5 mm², with or without cable ends. The body is small, with a net weight of 0.02 kg and a packaged size of about 4 × 4 × 2 cm for one unit. The block is fitted from the front of the operator unit, so it can be changed without dismantling the rear of the panel, which suits maintenance teams who work on stations that cannot be shut down for long.

Check the compatibility list on the datasheet before ordering for a given operator: this reference lists XB4, XAPS2, XACA and XB5. Do not assume that a block fits a head of another range just because it looks similar, and check the real operator when replacing parts on older stations.

Pairing ZB2BE101 with ZB2BE102

A control station that needs both a make and a break contact stacks one ZB2BE101 with one ZB2BE102, giving the familiar 1 NO plus NC arrangement. Keep the same order on every station so that a technician can identify the contacts by position, and mark the terminals ((13-14)NO) on the drawing so that a later replacement does not reverse the action.

Typical sites include pump houses, motor control centres, water treatment skids, desalination auxiliaries and process packages in Oman and the GCC, where operator stations take daily use and a worn block can stop a plant start. Keeping a few spare ZB2BE101 units in the store is a cheap precaution.

Contact action and circuit logic of the ZB2BE101

With the normally open contact the circuit is open at rest and closes while the operator is pressed and held. It is the make element of a start button, a jog button or a command to a PLC input. The datasheet describes the operation as slow-break and the circuit type as control circuit, single speed, which means the block is intended for ordinary command signals, not for fast-switching or multi-speed duty.

Operating force is 13 to 15 N at the contact, and the datasheet gives a maximum resistance across the terminals of 25 MΩ, a figure that confirms the contact is meant to be a clean on/off element rather than a measuring device. Since the block works in start, jog and acknowledge commands, wire it so that the intended safe state corresponds to the way the contact rests.

Technical specifications of the ZB2BE101

Parameter Specification
Manufacturer / part number Schneider Electric / ZB2BE101
Range Harmony XAC
Product type Contact block, single
Component name ZB2
Contacts 1 NO
Terminal marking (ISO) (13-14)NO
Circuit type Control circuit, single speed
Operator type Spring return
Mounting of block Front mounting
Contact operation Slow-break
Compatible products XB4, XAPS2, XACA and XB5
Thermal current [Ithe] 10 A (enclosed)
Rated insulation voltage [Ui] 600 V, pollution degree 3
Rated impulse withstand [Uimp] 6 kV
AC-15 rating 240 V / 3 A and 600 V / 1.2 A (A600)
DC-13 rating 250 V / 0.27 A and 600 V / 0.1 A (Q600)
Rated power DC-13 40 W at 120 V, 48 W at 48 V, 65 W at 24 V (1000000 cycles, below 3600 cycles/h, load factor 0.5)
Short-circuit protection 10 A cartridge fuse, type gG
Maximum resistance across terminals 25 MΩ limit stated in the datasheet
Operating force 13 to 15 N
Mechanical durability 1000000 cycles
Terminals Screw clamp: 1 × 2.5 mm² or 2 × 1.5 mm², with or without cable end
Net weight 0.02 kg
Operating temperature -25 to 70 °C
Storage temperature -40 to 70 °C
Vibration resistance 15 gn, 10 to 500 Hz
Shock protection class Class II, IEC 61140
Standards IEC 60947-5-1, IEC 60204-32, UL 508, CSA C22.2 No 14
Warranty 18 months

Selection checklist and RFQ information for ZB2BE101

Send the following with your enquiry so that we can match the part number with the datasheet and confirm availability in one reply.

  • Part number ZB2BE101 and the quantity required.
  • The contact action needed (NO or NC), and whether the sibling block is also needed.
  • The load: voltage, current and whether AC or DC, against the AC-15 and DC-13 ratings.
  • The operator or head it will be fitted to, checked against the compatible products on the datasheet.
  • A photo of the existing block and its nameplate when replacing.
  • Any project approval needed, compared with the standards on the datasheet.
  • Delivery location in Oman or the GCC and the lead time needed.

Load ratings of the ZB2BE101

The datasheet quotes a conventional enclosed thermal current of 10 A and utilisation ratings of 3 A at 240 V and 1.2 A at 600 V in AC-15, and 0.27 A at 250 V and 0.1 A at 600 V in DC-13. For DC loads at lower voltage, rated power is stated for one million cycles at 40 W at 120 V, 48 W at 48 V and 65 W at 24 V, at a load factor of 0.5 and below 3600 cycles per hour. These ratings tell the designer how much a coil, solenoid or lamp load the block can handle before contact life starts to fall below the stated durability of 1000000 mechanical cycles.

A 10 A cartridge fuse of type gG protects the block against short-circuit, as required by the datasheet. As on any control contact, the thermal current is a heating limit and not an invitation to switch a 10 A load, so use contactors for power and keep the ZB2BE101 for coils and signals.

Documents and quotation

The Schneider Electric datasheet for the ZB2BE101 is attached on this page for your technical file. It holds the electrical, mechanical and environmental data summarised above, with the drawings and packaging data.

To request a quotation, send the part number and quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please check the datasheet against your project requirements before ordering.

Datasheets & Documents
  • PDF Datasheet Schneider Electric ZB2BE101 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric ZB2BE101 ZB2 Contact Block, 1 NO

Answers from our engineering team on installation, compatibility and integration.

01What contact does the ZB2BE101 provide?
A single NO contact (1 NO), terminal marking (13-14)NO, slow-break action, for spring-return operators.
02Which operators is the ZB2BE101 listed for?
The datasheet lists XB4, XAPS2, XACA and XB5 as compatible products. Check the exact head before ordering.
03What are the contact ratings of the ZB2BE101?
3 A at 240 V and 1.2 A at 600 V in AC-15, 0.27 A at 250 V and 0.1 A at 600 V in DC-13, with 10 A enclosed thermal current and a 10 A gG fuse.
04How is the ZB2BE101 wired?
By screw clamp terminals taking one 2.5 mm² conductor or two 1.5 mm² conductors, with or without cable ends.
05Does Seven Star LLC supply the ZB2BE101 in Oman?
Yes, as an independent supplier in Muscat for Oman and the GCC. Send the part number and quantity and we confirm availability and documents.