Schneider Electric XB4BA11 White Flush Push-Button NO

Description

XB4BA11: white flush NO Harmony XB4 push-button

The XB4BA11 is a Schneider Electric Harmony XB4 metal push-button for a 22 mm panel hole. It has a plain unmarked white head, a flush spring-return operator and a NO contact configuration. Seven Star LLC supplies the XB4BA11 in Oman and the GCC as an independent supplier based in Muscat, usually to panel builders and maintenance buyers who need a robust operator for control desks and machine panels.

The reference breaks down in a way the datasheet titles suggest, though the manufacturer’s ordering table is the final authority: XB4B is the metal 22 mm operator family, A is the flush push-button head, and the remaining digits carry the colour and contact selection. General purpose start, acknowledge or select where the function is written on a nameplate. White is the neutral colour and is a frequent choice for a duty with no safety meaning.

Panel mounting and terminal wiring of the XB4BA11

The operator fits a standard 22.5 mm hole. The body measures 47 mm high, 30 mm wide and 52 mm deep, and weighs 0.08 kg, so the rear depth is the figure to check on shallow doors. The datasheet gives a tightening torque of 0.8 to 1.2 N.m for the terminals and lists screw heads compatible with Philips and pozidriv No 1 drivers as well as flat 4 mm and 5.5 mm blades.

Conductor capacity is up to two 1.5 mm² wires with cable ends, or single wires from 0.22 mm² upward without ends. The datasheet also states a resistance to a high-pressure washer of 7000000 Pa at 55 °C from 0.1 m, which is useful for food, beverage and marine-type duty, though a clean, undamaged seal against the panel is what makes the rating real in practice.

How the XB4BA11 operates

The head is spring return: pressing it moves the contact block and releasing it lets the spring return the head to rest. The normally open contact closes after 2.6 mm of travel and the total stroke is 4.3 mm. The operating force at the point of electrical change is stated as 3.8 N. Contact operation is slow-break, which is normal for control-circuit buttons and means contact speed follows the speed of the finger rather than a snap spring.

The datasheet lists positive opening as not provided, so the part suits start, jog and signalling functions; use a positive-opening variant where a welded contact could be dangerous, such as in a stop circuit. For XB4BA11 the contact terminals are marked (13-14)NO under the ISO numbering.

Technical specifications of the XB4BA11

Parameter Specification
Manufacturer / part number Schneider Electric / XB4BA11
Range Harmony XB4
Product type Push-button, spring return
Operator profile White flush, unmarked
Bezel / collar Chromium plated metal / zamak
Mounting diameter 22.5 mm
Contacts 1 NO, slow-break
Positive opening Without
Terminal marking (ISO) (13-14)NO
Operating travel 2.6 mm (NO changing electrical state); 4.3 mm (total travel)
Operating force 3.8 N NO changing electrical state
Mechanical durability 10 million cycles
Thermal current [Ith] 10 A conforming to IEC 60947-5-1
Rated insulation voltage [Ui] 600 V (pollution degree 3)
Rated impulse withstand [Uimp] 6 kV
Rated operational current [Ie] 3 A at 240 V, AC-15, A600; 6 A at 120 V, AC-15, A600; 0.1 A at 600 V, DC-13, Q600
Short-circuit protection 10 A cartridge fuse type gG
Electrical durability 1 million cycles, AC-15, 2 A at 230 V
Dimensions (H x W x D) 47 mm × 30 mm × 52 mm
Net weight 0.08 kg
Degree of protection IP66, IP67, IP69, IP69K; UL type 4X/13; IK06
Operating / storage temperature -40 to 70 °C / -40 to 70 °C
Certifications CSA, LROS (Lloyds register of shipping), BV, UL listed, DNV
Warranty 18 months

Contact ratings and life of the XB4BA11

The contact blocks are silver alloy (Ag/Ni). The thermal current is 10 A, the insulation voltage is 600 V at pollution degree 3 and the impulse withstand is 6 kV. Operational ratings include 3 A at 240 V and 6 A at 120 V in AC-15, and 0.27 A at 250 V and 0.55 A at 125 V in DC-13, with a 10 A gG cartridge fuse specified for short-circuit protection. These are control-circuit ratings: the contacts switch relay coils, PLC inputs and contactor coils rather than motors directly.

Electrical life is stated as 1 million cycles at 2 A, 230 V in AC-15, 3 A at 120 V and 4 A at 24 V, at up to 3600 operations an hour with a load factor of 0.5, plus 1 million cycles at 0.2 A, 110 V and 0.5 A, 24 V in DC-13. Mechanical life is 10 million operations. Electrical reliability for low-level signals is quoted at 1 mA and 5 V in a clean environment, a reminder to keep the contact atmosphere clean when the button feeds a PLC input.

Where XB4BA11 is used in Oman and the GCC

Metal push-buttons of this series are common on motor control centres, crane and hoist pendants, pump stations, packaged skids, conveyor panels and water treatment plants. In oil and gas and petrochemical sites they sit on local control stations and auxiliary panels; in desalination and power plants they appear on starter doors and operator desks. In practice the white head of the XB4BA11 is chosen for the function described earlier on this page, so keep the colour consistent with your legend.

The metal bezel resists knocks, sunlight and cleaning chemicals better than a plastic head, which matters on coastal sites where heat, dust and salt air are routine. Even so, mount the button where an accidental knock cannot operate it, or fit a protective collar if the plant standard asks for one.

Sealing, temperature and approvals of the XB4BA11

The chromium-plated metal bezel and zamak fixing collar give this operator a robust front face. The datasheet lists protection ratings of IP66, IP67, IP69, IP69K, and the unit is stated for UL type 4X/13 enclosures, so it can sit in washdown or dusty locations where a plain panel hole would not survive. Operating and storage temperatures are both given as -40 to 70 °C, a wide window that covers a summer-heated switch room as well as an unheated outdoor cabinet.

The approvals listed on the datasheet are CSA, LROS (Lloyds register of shipping), BV, UL listed, DNV. Marine and offshore projects often ask for the Lloyd’s Register, Bureau Veritas or DNV entries, but XB4BA11 should only be accepted against a requirement that appears on the datasheet for this exact reference. Vibration resistance is 5 gn between 2 and 500 Hz, with shock rated at 30 gn for 18 ms and 50 gn for 11 ms, figures worth quoting when the panel is mounted on a skid or on rotating plant.

Selection checklist and RFQ information for XB4BA11

Send the points below so that the part number can be confirmed against the datasheet and checked for availability in a single reply.

  • Required quantity and the full part number XB4BA11.
  • Panel thickness and the position of any anti-rotation key or nameplate.
  • Rear clearance behind the panel, checked against the body depth.
  • Control voltage and current of the circuit the contacts will switch.
  • Any approval needed by the project, such as marine or UL, compared with the datasheet.
  • Delivery location in Oman or the GCC and the lead time you need.
  • Confirmation that NO contacts and a white flush head match your circuit and legend.

Documents and quotation

The Schneider Electric datasheet for the XB4BA11 is attached on this page for your technical file. It carries the electrical, mechanical and environmental data summarised above, together with dimension and wiring drawings.

To request a quotation, send the part number and quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please check the datasheet against your project requirements before ordering.

Datasheets & Documents
  • PDF Datasheet Schneider Electric XB4BA11 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric XB4BA11 White Flush Push-Button

Answers from our engineering team on installation, compatibility and integration.

01What size panel hole does the XB4BA11 fit?
A standard 22.5 mm round hole. The datasheet gives the mounting diameter as 22.5 mm and a terminal tightening torque of 0.8 to 1.2 N.m.
02What contact configuration does the XB4BA11 have?
NO contacts: one normally open. Positive opening is not provided on this part.
03What protection rating does the XB4BA11 list?
The datasheet lists IP66, IP67, IP69, IP69K, with UL type 4X/13 and operation from -40 to 70 °C.
04How long is the mechanical life of the XB4BA11?
10 million operations, per the datasheet mechanical durability figure.
05Does Seven Star LLC supply the XB4BA11 in Oman?
Yes, as an independent supplier in Muscat serving Oman and the GCC. Send the part number and quantity and we confirm availability and documents.