- Automation & ControlView all 1,965 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Automation Accessories
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Motor Soft Starters
- Industrial Computers
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric XB5KS2B4 XB5 Red Buzzer 24 V AC/DC
Description
XB5KS2B4: red illuminated buzzer for a 22 mm panel hole, 24 V AC/DC
The XB5KS2B4 is a Schneider Electric Harmony XB5 illuminated buzzer in a plastic 22 mm housing. It gives a continuous or an intermittent tone, depending on which terminal is wired, with a stated noise level of 90 dB at 6.8 kHz measured at 0.1 m. Its rated supply is 24 V AC/DC. Seven Star LLC supplies the XB5KS2B4 in Oman and the GCC as an independent supplier based in Muscat.
Red marks an alarm or abnormal condition on most panel legends, so this version suits fault, trip or emergency annunciation where the operator must both hear and see the signal. The sibling references compared later on this page are the XB5KS2M4 and the XB5KSG; all three share the same 29 × 29 × 55 mm body and differ in supply voltage and cap colour.
Tone modes and wiring of the XB5KS2B4
The datasheet wiring diagram shows three connection points: the supply, an intermittent-tone terminal and a continuous-tone terminal. Which tone sounds is therefore a wiring decision made at installation, not a setting on the buzzer, and one XB5KS2B4 can serve either duty. A common arrangement is to feed the continuous terminal for an urgent condition and the intermittent terminal for a lower-priority warning, so that two meanings can be given by one device on different outputs.
The stated sound level is measured very close to the unit, at 0.1 m, with a tolerance of ±10 %. A sound level at the operator’s position will be lower and depends on the room, so for a noisy plant treat this part as a panel-level alert, not as a general alarm horn for a large hall. The connection is by screw clamp terminals or a plug-in connector, per the panel drawing in the datasheet.
Selection checklist and RFQ information for XB5KS2B4
Send the points below so that the part number can be confirmed against the datasheet and checked for availability in one reply.
- Part number XB5KS2B4 and quantity.
- The control voltage and whether it is AC or DC.
- Whether a continuous tone, an intermittent tone or both are needed.
- The cap colour required and the panel legend or nameplate.
- Panel thickness and the spacing to neighbouring 22 mm devices.
- Any approval to be shown, compared with the UL, CSA and BV entries on the datasheet.
- Delivery location in Oman or the GCC and the lead time you need.
Mounting the XB5KS2B4 in a panel
The this unit fits the standard 22.5 mm round hole; the datasheet recommends a finished diameter of 22.5 mm (22.3 mm with +0.4 mm tolerance). The clamping thickness range is 1 to 6 mm. The mounting drawing gives a minimum spacing between adjacent 22 mm devices of 40 mm in one direction and 30 mm in the other, so plan the door layout for those centres when a row of buzzers, lamps and buttons shares a plate.
Behind the panel the body measures 55 mm deep, with a net weight of only 0.024 kg, so rear clearance is rarely a problem on a standard door. Keep the cable entry and bending radius in mind where a plug-in connector is used.
Comparing XB5KS2B4 with XB5KS2M4 and XB5KSG
| Reference | Type and colour | Supply | Current |
|---|---|---|---|
| XB5KS2B4 | Illuminated buzzer, red | 24 V AC/DC | up to 58 mA |
| XB5KS2M4 | Illuminated buzzer, red | 230–240 V AC | up to 35 mA |
| XB5KSG | Complete buzzer, black | 110–120 V AC | up to 20 mA |
The this unit is the red 24 V AC/DC member of this group; select by control voltage first, then by cap colour.
Environment and approvals of the XB5KS2B4
The datasheet lists a UL type 4X/13 enclosure type and a resistance to a high-pressure washer of 9000000 Pa at 80 °C from 0.1 m. Operating and storage temperatures are both -40 to 70 °C. The overvoltage category is class II, and the protective treatment is code TH, the manufacturer’s code for tropical-climate protection. Certifications listed are UL listed, CSA and BV; the standards named include IEC 60947-5-1, IEC 60947-5-4, UL 508 and CSA C22.2 No 14.
These figures describe the front face of the XB5KS2B4 when installed correctly with its seal. Marine or offshore use must be justified against the exact BV entry on the datasheet. Do not assume hazardous-area suitability, since none is stated.
Technical specifications of the XB5KS2B4
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / XB5KS2B4 |
| Range | Harmony XB5 |
| Product type | Annunciator |
| Bezel material | Plastic |
| Cap / operator colour | Red |
| Mounting diameter | 22 mm |
| Signalling type | Continuous or intermittent tone |
| Noise level | 90 dB at 6.8 kHz, measured at 0.1 m, ±10 % |
| Rated supply voltage [Us] | 24 V ±10 %, AC or DC, 50/60 Hz |
| Supply type / frequency | AC/DC / 50/60 Hz |
| Current consumption | up to 58 mA |
| Height / width / depth | 29 × 29 × 55 mm |
| Net weight | 0.024 kg |
| Resistance to high-pressure washer | 9000000 Pa at 80 °C, distance 0.1 m |
| Enclosure type | UL type 4X/13 |
| Operating / storage temperature | -40 to 70 °C / -40 to 70 °C |
| Overvoltage category | Class II (IEC 60536) |
| Protective treatment | TH |
| Panel clamping thickness | 1 to 6 mm |
| Certifications | UL listed, CSA, BV |
| Warranty | 18 months |
Where XB5KS2B4 is used in Oman and the GCC
Panel buzzers of this kind give an audible cue on machine and process panels: pump and compressor skids, water treatment and desalination auxiliaries, packaging lines, workshop machines and small power distribution boards. The this unit is a compact way to add an audible indication without a separate sounder box. In hot, dusty or humid regional plants, the tropical protective treatment and wide temperature window are the relevant points, but always keep the unit behind a door seal that is in good condition.
It complements a pilot light rather than replacing one: the eye picks up the lamp, and the ear picks up the buzzer when the operator is facing away from the panel.
Supply voltage choice for the XB5KS2B4
The 24 V AC/DC rating is the flexible low-voltage choice. One reference serves a 24 V DC control bus, a PLC output card or a 24 V AC transformer winding, so a panel builder carries a single buzzer reference for machines that mix supplies. The datasheet lists a current draw of up to 58 mA, which is the highest of the three buzzers compared on this page, so check the capacity of a small PLC output before wiring several in parallel.
All three buzzers in this group use the same housing, so changing the voltage later means changing the part number, not the panel cut-out. Quote the control voltage of the panel in every enquiry for the this unit so that the right reference is checked.
Documents and quotation
The Schneider Electric datasheet for the XB5KS2B4 is attached on this page for your technical file. It holds the electrical, mechanical and environmental data summarised above, together with the dimension and panel cut-out drawings.
To request a quotation, send the part number and quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please check the datasheet against your project requirements before ordering.
Datasheets & Documents
- Datasheet Schneider Electric XB5KS2B4 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric XB5KS2B4 XB5 Red Buzzer 24 V
Answers from our engineering team on installation, compatibility and integration.
01What tones can the XB5KS2B4 produce?
Continuous or intermittent, selected by wiring the supply to the matching terminal shown in the datasheet connection diagram.
02What supply does the XB5KS2B4 use?
The datasheet gives 24 V ±10 %, AC or DC, 50/60 Hz, with a current consumption of up to 58 mA.
03How loud is the XB5KS2B4?
The datasheet lists 90 dB at 6.8 kHz, measured at 0.1 m with a ±10 % tolerance. Sound level at the operator is lower.
04What panel hole does the XB5KS2B4 fit?
A 22.5 mm round hole with a clamping thickness of 1 to 6 mm and a body depth of 55 mm.
05Does Seven Star LLC supply the XB5KS2B4 in Oman?
Yes, as an independent supplier in Muscat serving Oman and the GCC. Send the part number and quantity and we confirm availability and documents.


















Reviews
There are no reviews yet.