Brand: Schneider Electric
Schneider Electric A9N61508 C60H-DC 1P 10 A C Curve
Description
A9N61508: C60H-DC 1P 10 A C-curve breaker
The A9N61508 is a Schneider Electric Acti9 C60H-DC miniature circuit-breaker with 1 protected pole, a rated current of 10 A and a C trip curve. Although the shop title only says miniature circuit breaker, the datasheet lists the network type as DC, so this is a direct-current device and should not be confused with the AC members of the Acti9 range. Seven Star LLC supplies the A9N61508 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference from the datasheet rather than from the number itself: A9N61508 is the 10 A step in the 1-pole ladder, it is rated for 250 V DC, and it occupies 2 modules of 9 mm on the DIN rail. A single-pole version has one switching contact, so the other conductor of the circuit is not interrupted by the breaker.
Technical specifications of the A9N61508
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / A9N61508 |
| Range / product name | Acti9 / Acti9 C60H-DC (short name C60H-DC) |
| Product type | Miniature circuit-breaker for DC distribution |
| Poles | 1P (1 protected pole) |
| Rated current [In] | 10 A at 25 °C |
| Network type | DC (frequency field lists 50/60 Hz) |
| Trip unit | Thermal-magnetic, curve C |
| Rated operational voltage [Ue] | 250 V DC |
| Rated insulation voltage [Ui] | 500 V DC |
| Rated impulse withstand [Uimp] | 6 kV |
| Breaking capacity Icu (IEC 60947-2) | 20 kA at 110 V DC; 10 kA at 220 V DC; 6 kA at 250 V DC |
| Service breaking capacity Ics (75 % of Icu) | 15 kA at 110 V DC; 7.5 kA at 220 V DC; 4.5 kA at 250 V DC |
| Utilisation category | Category A |
| Isolation suitability | Yes, IEC 60947-2 |
| Standards | EN 60947-2, IEC 60947-2 |
| Control / indication / padlocking | Toggle; contact position indicator; ON/OFF indication; padlockable in position O |
| Mounting | Fixed, 35 mm symmetrical DIN rail; comb busbar compatible top or bottom |
| Width in 9 mm pitches | 2 |
| Net weight | 0.128 kg |
| Tightening torque | 2.5 N.m, power circuit top or bottom |
| Durability | 20000 mechanical cycles; 3000 electrical cycles, L/R = 2 ms |
| Pollution degree / overvoltage category | 3 / IV |
| Operating / storage temperature | -25–70 °C / -40–85 °C |
| Operating altitude | 2000 m |
| Warranty | 18 months |
1P and 2P C60H-DC references in the family
The single-pole ladder that we handle includes A9N61511 (16 A), A9N61512 (20 A), A9N61519 (63 A). A9N61508 shares the 250 V DC rating, 0.128 kg weight and 2-module width with them, so current rating is the one datasheet difference between these four.
The two-pole references (A9N61521 (1 A), A9N61522 (2 A), A9N61523 (3 A), A9N61524 (4 A), A9N61525 (5 A), A9N61526 (6 A), A9N61528 (10 A), A9N61531 (16 A), A9N61532 (20 A), A9N61533 (25 A), A9N61535 (32 A), A9N61539 (63 A)) have a different electrical personality: a 500 V DC rated voltage, 4 modules of width and 0.256 kg. Choose the 2P series if the system voltage is above 250 V DC or if you want both conductors disconnected by one operating handle.
Installation, commissioning and maintenance of the A9N61508
The A9N61508 clips onto a 35 mm symmetrical DIN rail and is fixed mounting. The power terminals, top or bottom, accept a tightening torque of 2.5 N.m; use a calibrated driver rather than judgement, because DC contacts that are under-tightened heat up and can degrade slowly. The datasheet lists comb busbar compatibility at top or bottom in standard configuration, which allows neat feeder groups in a distribution board.
At commissioning, verify polarity against the wiring diagram, operate the toggle several times, confirm that the contact position indicator and the ON/OFF indication agree with the actual state, and check that the padlocking provision in position O works with your lock-out procedure. Mechanical durability is stated as 20000 cycles and electrical durability as 3000 cycles at L/R = 2 ms, so an annual operation check is reasonable, but do not use the breaker as a routine switch for heavy inductive loads.
What to send with an RFQ for the A9N61508
To quote the A9N61508 quickly, send the complete part number, the quantity, the system DC voltage and earthing arrangement, the highest prospective fault current, whether you need 1 pole, and the delivery location in Oman or the GCC. Mention if it replaces an existing device so we can compare labels.
How a thermal-magnetic DC breaker protects the circuit
The A9N61508 uses a thermal-magnetic trip unit. The thermal element reacts to a sustained overload by bending as the conductor heats, giving a delayed trip that tolerates short switching surges. The magnetic element reacts to a short circuit almost instantly. The curve code on the datasheet is C, which places the instantaneous threshold higher than a B curve and suits loads with moderate inrush.
Interrupting direct current is harder than interrupting alternating current because there is no natural current zero to help extinguish the arc. That is the reason the datasheet gives breaking capacity separately for each DC voltage: 20 kA at 110 V DC, 10 kA at 220 V DC and 6 kA at 250 V DC. Service capacity Ics, at 75 % of those values, is 15 kA at 110 V DC, 7.5 kA at 220 V DC and 4.5 kA at 250 V DC. The lower the system voltage, the higher the fault current the device can clear, so always compare the prospective fault current at your actual bus voltage with the matching line, not with the largest number.
Selecting the A9N61508 for your DC circuit
The 10 A step is where branch cabling starts to become more than control-wire and the conductor, not the breaker, often sets the limit. A 10 A rating sits in the middle of the family and is commonly used for DC lighting circuits, small converters, control cabinets supply lines and motor-control auxiliaries. Compare the continuous current with the 10 A rating after considering enclosure temperature, because the value on the datasheet refers to 25 °C. If several breakers sit side by side on the same rail, allow for mutual heating. This is the first step of the 1-pole ladder in our lane; the next rating up is A9N61511 at 16 A.
- Highest system voltage: must not exceed 250 V DC.
- Prospective short-circuit current at the breaker location, compared with the Icu line for that voltage.
- Continuous load current and ambient temperature inside the enclosure.
- Number of poles needed: 1 here; confirm whether your earthing arrangement needs both conductors switched.
- Polarity or terminal markings: follow the marks on the device and the wiring diagram supplied with the installation.
Typical use of the A9N61508 in Oman and the GCC
DC distribution appears in the region in substations, power plants, telecom shelters, solar-powered monitoring stations, battery rooms and process control cabinets in oil and gas, petrochemical and desalination facilities. A mid-range branch like this one, rated 10 A, is usually found on control-room auxiliary supplies and converter inputs. The datasheet gives an operating range of -25 to 70 °C, tropicalisation level 2, pollution degree 3 and altitude up to 2000 m, which is a useful starting point for panels in hot, dusty, humid coastal sites; keep panels out of direct sun.
Documents and quotation
A datasheet for the A9N61508 is attached on this page. The copy we reviewed is dated 8 Nov 2026 and lists the environmental data of the reference as well as the electrical values above.
Send the part number and your project details through the RFQ form; Seven Star LLC will confirm availability and lead time in Oman and the GCC.
Datasheets & Documents
- Datasheet Schneider Electric A9N61508 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric A9N61508 C60H-DC 1P 10 A C Curve
Answers from our engineering team on installation, compatibility and integration.
01Is the A9N61508 an AC or DC breaker?
The datasheet lists the network type as DC. The A9N61508 is part of the Acti9 C60H-DC family, with a rated operational voltage of 250 V DC, so it is meant for direct-current circuits.
02What is the breaking capacity of the A9N61508?
It is stated as 20 kA at 110 V DC, 10 kA at 220 V DC and 6 kA at 250 V DC under IEC 60947-2. Always compare the figure for your actual bus voltage.
03How many modules does the A9N61508 occupy?
It occupies 2 modules of 9 mm on a 35 mm DIN rail and has a net weight of 0.128 kg. Comb busbars are compatible at top or bottom.
04Which trip curve does the A9N61508 use?
It is a thermal-magnetic unit with curve code C and a rated current of 10 A at 25 °C. Request the trip-curve document from the manufacturer for exact thresholds.
05Can the A9N61508 be used as an isolator?
The datasheet states suitability for isolation under IEC 60947-2 and a contact position indicator. It is padlockable in position O, which supports lock-out procedures.