Schneider Electric A9N15636 Acti9 STI 1P fuse-disconnector
Description
A9N15636: Acti9 STI single-pole fuse-disconnector for 10.3 × 38 mm mm fuses
The A9N15636 is a Schneider Electric Acti9 STI fuse-disconnector: a DIN-rail fuse holder with a hinged carrier that takes 10.3 × 38 mm mm cartridge fuses, single-pole and up to 25A per pole. Seven Star LLC supplies the A9N15636 in Oman and the GCC as an independent supplier based in Muscat. Pulling the carrier opens the circuit and lets the user replace the fuse without tools on the live side of the panel.
This unit is described in the title as 1P, 25 A and for fuse 10.3 × 38 mm mm. This is the 10.3 × 38 mm version, so the cartridge size, the rated voltage (500 V AC) and the permitted current range are specific to this reference and differ from its siblings.
Technical specifications of the A9N15636
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / A9N15636 |
| Range / product | Acti9 STI |
| Type | Fuse-disconnector |
| Poles | 1P |
| Rated current [In] | 2A / 4A / 6A / 10A / 16A / 20A / 25A |
| Fuse type | aM fuse / gG fuse |
| Fuse size | 10.3 × 38 mm mm |
| Rated operational voltage | 500 V AC |
| Rated insulation voltage | 500 V AC 50/60 Hz |
| Dimensions (H × W × D) | 81 × 18 × 75 mm (2 modules of 9 mm) |
| Colour | White |
| Mounting | Clip-on, DIN rail |
| Terminals | Screw clamp: 1 cable 0.75–10 mm² rigid or 0.5–6 mm² flexible; 2 cables 0.75–4 mm² rigid or 0.5–6 mm² flexible |
| Stripping length / torque | 12 mm / 2 N.m |
| Ingress protection | IP20 |
| Pollution degree | 3 |
| Operating temperature | -20–60 °C |
| Storage temperature | -40–80 °C |
| Standards | IEC EN 60947-3, IEC 60269-1/2 |
Where the A9N15636 is used in Oman and the GCC
Fuse-disconnectors of this kind are used in control cabinets for pumps and fans, in lighting and power distribution boards, on supply circuits of instrumentation and PLCs, and in motor-starter panels where aM fuses are specified. The 10.3 × 38 mm size fits motor feeders and heavier auxiliary circuits in industrial plants, water treatment and oil and gas utility buildings. The listed operating range is -20–60 °C, so panels in hot rooms should be ventilated and de-rated at the fuse according to the fuse maker’s data. Fine desert dust is best kept out with a gasketed enclosure since the module itself is only IP20.
STI references to compare with the A9N15636
The table lists the other STI modules in the same series so that you can match pole count and fuse size.
| Part number | Poles | Fuse size | Max current | Width |
|---|---|---|---|---|
| A9N15635 | 1P | 8.5 × 31.5 mm mm | 10A | 18 mm |
| A9N15651 | 2P | 10.3 × 38 mm mm | 25A | 36 mm |
| A9N15656 | 3P | 10.3 × 38 mm mm | 25A | 54 mm |
| A9N15658 | 3P+N | 10.3 × 38 mm mm | 25A | 54 mm |
Selection checklist and RFQ details for the A9N15636
Confirm the following.
- Fuse size: 10.3 × 38 mm mm, matched to the cartridges you already stock.
- Fuse current: up to 25A, and gG or aM type according to the load.
- Pole count: 1P (as required).
- Voltage: 500 V AC rated operational voltage.
- Space: 18 mm of rail.
Send with your RFQ:
- Part number A9N15636 and quantity.
- Whether fuse links are also needed, with type and current.
- Circuit voltage and load type.
- Delivery location and date.
Fuse size and ratings of the A9N15636
The 10.3 × 38 mm cartridge takes the common mid-size industrial fuse and is listed up to 25 A at 500 V AC rated operational voltage, so it can also protect small motor feeders and contactor-controlled branches at 400 V.
Listed currents for this module are 2A, 4A, 6A, 10A, 16A, 20A, 25A. These are the values of the fuse link that can be fitted, not a rating of the holder alone; always check that the fuse type, size and voltage rating printed on the cartridge match the data for this unit. Fitting an oversized cartridge defeats the cable protection and is a common installation fault.
Installation and replacement notes
The module is 18 mm wide (2 modules of 9 mm) and clips onto a DIN rail. The screw clamp terminals accept one conductor of 0.75–10 mm² rigid or 0.5–6 mm² flexible, or two conductors of up to 4 mm² rigid or 6 mm² flexible; strip 12 mm and tighten to 2 N.m.
To replace a fuse, isolate the supply, open the hinged carrier, remove the blown fuse, check the circuit for the cause of the failure and fit a new fuse of the same type and rating. Do not bridge the holder. Inspect terminals at each planned shutdown: fuse holders that carry load current close to rating often run warm, and a loose screw shows first as discolouration of the plastic. Because the A9N15636 is IP20, finger-safe access only applies once it is mounted behind a panel door or inside an enclosure.
How the A9N15636 isolates and protects
A fuse-disconnector combines two functions in one module. The cartridge fuse provides short-circuit and overload protection at its own characteristic, and the hinged carrier gives a visible, tool-free means to open the circuit for maintenance. For this unit the datasheet lists both aM and gG cartridges: gG (general purpose) covers cables and mixed loads, while aM is a motor-circuit fuse that only provides short-circuit protection and must be paired with a thermal overload relay. Which one you choose, and the amperage, sets what the circuit is protected against; the module is only the holder.
Only one pole and one fuse are carried here, so a three-phase circuit needs three of these modules side by side or a multi-pole STI such as the A9N15656.
Documents and quotation
The manufacturer’s product datasheet for the A9N15636 is attached on this page for reference; it is the document to use when you verify ratings, dimensions and approvals against your own design. It lists the rated values for this exact reference.
To receive a quotation, send the part number A9N15636 with quantity and delivery location in Oman or the GCC. Seven Star LLC replies with availability and lead time as an independent supplier based in Muscat.
Other Models in the Schneider Sti Range
Seven Star LLC supplies models from the Schneider Sti range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric A9N15635 Acti9 STI 1P fuse-disconnector | Automation Accessories | View details |
| Schneider Electric A9N15636 Acti9 STI 1P fuse-disconnector | Automation Accessories | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric A9N15636 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric A9N15636 Acti9 STI 1P
Answers from our engineering team on installation, compatibility and integration.
01What fuses fit the A9N15636?
It takes 10.3 x 38 mm mm cartridge fuses, listed as aM and gG types, with current values up to 25 A.
02What is the rated voltage of the A9N15636?
The datasheet lists a rated operational voltage of 500 V AC for this reference.
03How wide is the A9N15636?
It is 18 mm wide, which is 2 modules of 9 mm, 81 mm high and 75 mm deep, clip-on DIN rail mounting.
04What conductors can be connected to the A9N15636?
Screw clamp terminals take one cable of 0.75-10 mm2 rigid or 0.5-6 mm2 flexible, or two cables of up to 4 mm2 rigid or 6 mm2 flexible, with 12 mm stripping and 2 N.m torque.
05Does the A9N15636 include the fuses?
The datasheet describes the fuse-disconnector only. Fuse links are selected by type and current and are quoted separately if you need them.