Hydac HDA 47F9-A-0300-DV-000 Ex d Pressure Transmitter 300 psi

Description

The Hydac HDA 47F9-A-0300-DV-000 is the 300 psi flameproof pressure transmitter that most often turns up in maintenance requests for hydraulic power units and valve-actuation stations. Its two-wire 4 to 20 mA output leaves the welded 316L housing through a 1/2-14 NPT conduit thread, and the process side is a 1/4-18 NPT female port. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

What the order code of HDA 47F9-A-0300-DV-000 tells you

Read from the left: HDA 4700 series, connection letter F for female 1/4-18 NPT, electrical letter 9 for conduit with single cores, A for 4 to 20 mA, 0300 for 300 psi, D for the combined CSA, ATEX and IECEx approval, V for a vented gauge cell, and 000 for the standard build. Typing any one of these characters wrongly gives a different instrument, so keep the string intact when you quote HDA 47F9-A-0300-DV-000.

Key features

  • Range 0 to 300 psi with overload 1160 psi and burst 2900 psi.
  • Vented gauge measuring cell, the largest range offered in that cell type.
  • Single cores: red signal plus, black signal minus, green-yellow earth.
  • Marks: I M2 Ex d I Mb, II 2G Ex d IIC T6/T5 Gb, II 2D Ex tb IIIC T110 to 130 degC Db.
  • CSA Class I groups A to D, Class II groups E to G, Class III, Type 4.
  • IP 65 protection, vibration resistance 20 g from 10 to 500 Hz.

Technical data table for HDA 47F9-A-0300-DV-000

Parameter Value
Model code HDA 47F9-A-0300-DV-000
Material number (catalog) 921878
Measuring range 0 to 300 psi
Overload pressure 1160 psi
Burst pressure 2900 psi
Cell type Vented gauge (V)
Process connection 1/4-18 NPT, female
Tightening torque 30 lb-ft (40 N·m)
Electrical connection 1/2-14 NPT conduit, single cores
Cores / cable red, black, green-yellow; signal plus, signal minus, housing
Output 4 to 20 mA, 2-wire, load RLmax = (UB – 8 V) / 20 mA in kOhm
Supply voltage 8 to 30 V DC, residual ripple 5 percent or less, about 25 mA
Accuracy (terminal based) 0.25 percent FS typical and maximum; best-fit line 0.15 percent typical
Non-linearity / hysteresis / repeatability 0.3 / 0.1 / 0.05 percent FS maximum
Temperature coefficient (zero, span) 0.008 percent FS per degC typical, 0.015 maximum
Rise time / long-term drift 1.5 ms or less / 0.1 percent FS per year
Wetted parts Stainless steel 1.4542, 1.4571, 1.4435, 1.4404, 1.4301; FKM seal
Housing / conduit 1.4404 and 1.4435 (316L)
Compensated temperature T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF
Operating and fluid temperature T5: -4 to 176 degF; T6: -4 to 140 degF (FKM seal)
Storage temperature -40 to 212 degF
Protection IP 65 (vented gauge)
Vibration 20 g, 10 to 500 Hz
Weight 0.661 lb (about 300 g)
Approvals ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X

Where HDA 47F9-A-0300-DV-000 is used

Think of a blow-out preventer accumulator panel, a drill-drive hydraulic unit or an underground vehicle where the pressure range sits between 100 and 300 psi: charge pressure, pilot supply and brake release lines. In Gulf plants the same span appears on instrument-air headers and glycol pump discharge within classified areas. The transmitter replaces a stack of three separate approved devices with one nameplate, which simplifies the spares list.

How HDA 47F9-A-0300-DV-000 differs from other variants in the family

Compared with the 47F9 0100 version, the range triples from 100 to 300 psi, overload rises from 290 to 1160 psi and burst from 1450 to 2900 psi. Compared with 478G-A-0300, the connection is female not male and the wires are single cores rather than white, brown, green and yellow flying leads. Compared with 477G-A-0300, the process thread is 1/4 NPT with a 40 N·m torque value rather than SAE 6 at 20 N·m.

Selection notes

If the medium contains hydrogen sulfide or strong amines, check the wetted steels against the process fluid; the seal on HDA 47F9-A-0300-DV-000 is FKM. For a line that sees spikes beyond 1160 psi, step up to a 1000 psi or 1500 psi range instead of relying on the overload reserve. Female NPT means your pipe stub must be male.

Installation steps

Seat the 1/4 NPT stub with a suitable sealant, tighten with the hex only to 40 N·m and orient the conduit entry to drain away from the vent. Terminate the single cores in a certified junction box, connect the earth core, and verify 4 mA at zero and 20 mA at 300 psi. File the certificate numbers with the loop folder of HDA 47F9-A-0300-DV-000.

Maintenance

No routine adjustment is specified. Compare the output against a reference gauge once a year, check that the venting path remains open, and look for damaged conduit seals. A unit of type HDA 47F9-A-0300-DV-000 that drifts beyond 0.25 percent of full scale should be exchanged rather than opened.

Other values of this code run 0100, 0500, 1000, 1500, 3000, 5000 psi and higher, with M12 or conduit alternatives in sister families. The code of HDA 47F9-A-0300-DV-000 is the safest reference when a project list only shows a tag number.

Frequently asked questions about HDA 47F9-A-0300-DV-000

What pressure can HDA 47F9-A-0300-DV-000 measure? It measures 0 to 300 psi as a vented gauge value. The catalog gives 1160 psi overload and 2900 psi burst pressure, which is four times and nearly ten times the span.

Is 300 psi the limit of the vented cell? Yes. The datasheet says the vented gauge cell is offered up to 300 psi, so 0300 is the highest range in the V group; sealed gauge cells start at 500 psi.

How are the cores identified on this variant? Red carries signal plus, black carries signal minus and the green-yellow core is the housing connection, because the 47F9 code uses single cores in the 1/2-14 NPT conduit.

What is the weight and the temperature class? The catalog weight is 0.661 lb. Compensated range is -13 to 176 degF for T5 and T130 and -13 to 140 degF for T6 and T110.

How do I order HDA 47F9-A-0300-DV-000 for a project in Oman? Send the part number, quantity and your delivery port or site to Seven Star LLC by RFQ and we confirm availability and the datasheet.

Documents and quotation

The datasheet for HDA 47F9-A-0300-DV-000 is provided with this listing. Send an RFQ naming HDA 47F9-A-0300-DV-000, the quantity and delivery location; we respond with availability, lead time and certificate documents.

Other Models in the HDA 4700 ExD Range

Seven Star LLC supplies models from the HDA 4700 ExD range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hydac HDA 478G-A-0200-DV-000 Ex d Transmitter, 1/4 NPT MalePressure TransmittersView details
Hydac HDA 478G-A-0300-DV-000 Flameproof Transmitter 300 psiPressure TransmittersView details
Hydac HDA 47FG-A-0200-DV-000 Flameproof Transmitter, Flying LeadsPressure TransmittersView details
Hydac HDA 477G-A-0300-DV-000 SAE-6 Flameproof TransmitterPressure TransmittersView details
Hydac HDA 47F9-A-0300-DV-000 Ex d Pressure Transmitter 300 psiPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Hydac HDA 47F9-A-0300-DV-000 Ex d Pressure Transmitter 300 psi Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac HDA 47F9-A-0300-DV-000 Ex d Pressure

Answers from our engineering team on installation, compatibility and integration.

01What pressure can HDA 47F9-A-0300-DV-000 measure?
It measures 0 to 300 psi as a vented gauge value. The catalog gives 1160 psi overload and 2900 psi burst pressure, which is four times and nearly ten times the span.
02Is 300 psi the limit of the vented cell?
Yes. The datasheet says the vented gauge cell is offered up to 300 psi, so 0300 is the highest range in the V group; sealed gauge cells start at 500 psi.
03How are the cores identified on this variant?
Red carries signal plus, black carries signal minus and the green-yellow core is the housing connection, because the 47F9 code uses single cores in the 1/2-14 NPT conduit.
04What is the weight and the temperature class?
The catalog weight is 0.661 lb. Compensated range is -13 to 176 degF for T5 and T130 and -13 to 140 degF for T6 and T110.
05How do I order HDA 47F9-A-0300-DV-000 for a project in Oman?
Send the part number, quantity and your delivery port or site to Seven Star LLC by RFQ and we confirm availability and the datasheet.