- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Hydac
Hydac HDA 477G-A-0300-DV-000 SAE-6 Flameproof Transmitter
Description
Hydac HDA 477G-A-0300-DV-000 is the SAE-6 member of the 300 psi flameproof family. The process end is a 9/16-18 UNF 2A male thread with an O-ring face, typical of hydraulic blocks, manifolds and test points, and the electrical side is a 1/2-14 NPT conduit thread with a cable of 5 m as stated in the catalog description. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Where the SAE-6 port matters
Hydraulic cartridge blocks and valve manifolds often carry an SAE-6 gauge port. Fitting a 1/4 NPT transmitter would need an adapter, and every adapter is one more leak path. HDA 477G-A-0300-DV-000 avoids that: it seals on an O-ring face and requires only 20 N·m, half the 40 N·m of the NPT versions.
The cable is the other distinguishing feature: the catalog line for this material number says 5 m, whereas other units in the family are listed with 72 inches. Confirm the length on your drawing before an order, because a cable cut too short in a hazardous area cannot be spliced inside the plant without a certified enclosure. Also remember that the O-ring face seals the port, so surface finish of the SAE-6 bore matters more than thread sealant.
Features of HDA 477G-A-0300-DV-000
- SAE-6 male, 9/16-18 UNF 2A, 20 N·m (15 lb-ft).
- Cable length 5 m in the catalog description of this item.
- Triple approval for mining and for gas and dust zones.
- Range 0 to 300 psi, 1160 psi overload, 2900 psi burst.
- Weight 0.661 lb, IP 65 vented gauge cell.
- 4 to 20 mA, supply 8 to 30 V DC.
Technical specification of HDA 477G-A-0300-DV-000
| Parameter | Value |
|---|---|
| Model code | HDA 477G-A-0300-DV-000 |
| Material number (catalog) | 923819 |
| Measuring range | 0 to 300 psi |
| Overload pressure | 1160 psi |
| Burst pressure | 2900 psi |
| Cell type | Vented gauge (V) |
| Process connection | SAE-6 male, 9/16-18 UNF 2A |
| Tightening torque | 15 lb-ft (20 N·m) |
| Electrical connection | 1/2-14 NPT conduit, open-ended cable |
| Cores / cable | 5 m cable per catalog description; white signal plus, brown signal minus, green and yellow not used |
| Output | 4 to 20 mA, 2-wire, load RLmax = (UB – 8 V) / 20 mA in kOhm |
| Supply voltage | 8 to 30 V DC, residual ripple 5 percent or less, about 25 mA |
| Accuracy (terminal based) | 0.25 percent FS typical and maximum; best-fit line 0.15 percent typical |
| Non-linearity / hysteresis / repeatability | 0.3 / 0.1 / 0.05 percent FS maximum |
| Temperature coefficient (zero, span) | 0.008 percent FS per degC typical, 0.015 maximum |
| Rise time / long-term drift | 1.5 ms or less / 0.1 percent FS per year |
| Wetted parts | Stainless steel 1.4542, 1.4571, 1.4435, 1.4404, 1.4301; FKM seal |
| Housing / conduit | 1.4404 and 1.4435 (316L) |
| Compensated temperature | T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF |
| Operating and fluid temperature | T5: -4 to 176 degF; T6: -4 to 140 degF (FKM seal) |
| Storage temperature | -40 to 212 degF |
| Protection | IP 65 (vented gauge) |
| Vibration | 20 g, 10 to 500 Hz |
| Weight | 0.661 lb (about 300 g) |
| Approvals | ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X |
Application cases
Use it on a hydraulic power unit inside a mine, a blow-out preventer control manifold or a pump skid whose manifold was drilled for SAE ports. The 5 m lead reaches a nearby junction box without an extra cable run, which is convenient on mobile equipment that is hazardous-area certified.
How HDA 477G-A-0300-DV-000 differs from the 478G and 47F9 codes
The change relative to HDA 478G-A-0300-DV-000 is only the port: SAE-6 instead of 1/4 NPT. The cable is the same type of flying lead. Against 47F9-A-0300 the wires differ and the thread differs. The torque value of HDA 477G-A-0300-DV-000 is 20 N·m, the lowest in the family, matching the SAE-6 and autoclave F 250 C entries of the datasheet.
Selecting correctly
Confirm that the manifold port is SAE-6 with an O-ring seat, because a 7/16 or 3/4 UNF port needs another model. If the system uses water glycol, verify FKM compatibility. For pressures beyond 300 psi use a sealed gauge cell range from the same family.
Installation
Lubricate the O-ring lightly, thread by hand to avoid cross-threading, and torque only the hex to 20 N·m. Run the 5 m cable to a certified box with a rated gland, connect white and brown to the loop and take the supply between 8 and 30 V DC. After wiring, record 4 mA at zero pressure for HDA 477G-A-0300-DV-000.
Maintenance
Renew the O-ring whenever the transmitter is removed, since a flattened ring is the most likely leak. The sensor itself has no service parts. Verify zero yearly; the drift rating of HDA 477G-A-0300-DV-000 is 0.1 percent of full scale per year.
When the old unit shows only an SAE reference on its label, use the order key to locate HDA 477G-A-0300-DV-000. We confirm port, cable and range in writing before delivery.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the Hydac HDA 477G-A-0300-DV-000, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Hydac pressure transmitters items can be checked against the bill of materials quickly.
Frequently asked questions about HDA 477G-A-0300-DV-000
What process connection does HDA 477G-A-0300-DV-000 have? It has an SAE-6 male port, 9/16-18 UNF 2A, tightened to 20 N·m (15 lb-ft).
How long is the cable? The catalog description of this material number states 5 m, while sister units are shown with 72 inches.
What is the wiring? White is signal plus, brown is signal minus; green and yellow are unused.
What ranges, overload and burst apply? 0 to 300 psi, 1160 psi overload and 2900 psi burst.
How do I enquire? Send an RFQ to Seven Star LLC quoting HDA 477G-A-0300-DV-000, quantity and delivery location.
Documents and quotation
The datasheet of HDA 477G-A-0300-DV-000 is available on this page. For pricing contact us with an RFQ listing HDA 477G-A-0300-DV-000, the number of units and your delivery point.
Other Models in the HDA 4700 ExD Range
Seven Star LLC supplies models from the HDA 4700 ExD range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Hydac HDA 478G-A-0200-DV-000 Ex d Transmitter, 1/4 NPT Male | Pressure Transmitters | View details |
| Hydac HDA 478G-A-0300-DV-000 Flameproof Transmitter 300 psi | Pressure Transmitters | View details |
| Hydac HDA 47FG-A-0200-DV-000 Flameproof Transmitter, Flying Leads | Pressure Transmitters | View details |
| Hydac HDA 477G-A-0300-DV-000 SAE-6 Flameproof Transmitter | Pressure Transmitters | You are viewing this model |
| Hydac HDA 47F9-A-0300-DV-000 Ex d Pressure Transmitter 300 psi | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Hydac HDA 477G-A-0300-DV-000 SAE-6 Flameproof Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac HDA 477G-A-0300-DV-000 SAE-6 Flameproof
Answers from our engineering team on installation, compatibility and integration.
01What process connection does HDA 477G-A-0300-DV-000 have?
It has an SAE-6 male port, 9/16-18 UNF 2A, tightened to 20 N·m (15 lb-ft).
02How long is the cable?
The catalog description of this material number states 5 m, while sister units are shown with 72 inches.
03What is the wiring?
White is signal plus, brown is signal minus; green and yellow are unused.
04What ranges, overload and burst apply?
0 to 300 psi, 1160 psi overload and 2900 psi burst.
05How do I enquire?
Send an RFQ to Seven Star LLC quoting HDA 477G-A-0300-DV-000, quantity and delivery location.


















Reviews
There are no reviews yet.