- Automation & ControlView all 2,736 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Hydac
Hydac HDA 4385-A-0250-000-F1 Ceramic Pressure Transmitter 250 psi
Description
HDA 4385-A-0250-000-F1 extends the HDA 4300 ceramic-cell concept to 250 psi. It is a compact transmitter, about 150 g, with a 1/4-18 NPT male stainless connection, an FKM seal and a DIN 43650 plug. The same cell family is used by Hydac for refrigeration, air conditioning, food and pharmaceutical applications. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Where HDA 4385-A-0250-000-F1 sits in the family
The 250 psi range is the upper-middle step of the ceramic series, which stops at 500 psi. Overload of 725 psi and burst of 1000 psi are 2.9 and 4 times the range. Hysteresis is limited to 0.4 percent of full scale and non-linearity to 0.5 percent, so total error is dominated by those terms rather than by temperature.
For scaling, a controller input range of 4 to 20 mA corresponds to 0 to 250 psi, so every milliamp above 4 mA equals 15.6 psi. A measured 8 mA therefore indicates 62.5 psi. The accuracy at maximum setting of 1 percent of full scale equals 2.5 psi, which is why alarm points should be placed with that margin when they protect equipment.
Features
- Range 0 to 250 psi.
- Ceramic thick-film cell, stainless connection.
- FPM seal marked F; fluid temperature up to 212 degF.
- Plug supplied, IP 65.
- 25 mA or less; supply 8 to 30 V DC.
- Life expectancy above 10 million cycles.
Technical data for HDA 4385-A-0250-000-F1
| Parameter | Value |
|---|---|
| Model code | HDA 4385-A-0250-000-F1 |
| Material number (catalog) | 908593 |
| Measuring range | 0 to 250 psi |
| Overload pressure | 725 psi |
| Burst pressure | 1000 psi |
| Sensor cell | Ceramic, thick-film strain gauge |
| Process connection | 1/4-18 NPT male, stainless steel |
| Tightening torque | 30 lb-ft (40 N·m) |
| Seal | FKM (code F) |
| Output signal | 4 to 20 mA, 2-wire; load RLmax = (UB – 8 V) / 20 mA in kOhm |
| Supply voltage | 8 to 30 V DC, ripple 5 percent or less |
| Current consumption | 25 mA or less |
| Accuracy (terminal based) | 0.5 percent FS typical, 1 percent maximum at max. setting |
| Accuracy (best-fit line) | 0.25 percent FS typical, 0.5 percent maximum |
| Temperature coefficient | 0.012 percent FS per degF typical, 0.017 maximum |
| Non-linearity / hysteresis | 0.5 / 0.4 percent FS maximum |
| Repeatability / rise time | 0.1 percent FS / 1 ms or less |
| Long-term drift | 0.3 percent FS per year typical |
| Electrical connection | EN175301-803 (DIN 43650), 3-pole + PE, mating connector supplied |
| Protection class | IP 65 with the DIN 43650 connector |
| Compensated temperature | -13 to 185 degF |
| Fluid temperature | -13 to 212 degF with FPM seal |
| Storage temperature | -40 to 212 degF |
| Vibration | 20 g, 10 to 500 Hz |
| Life expectancy | more than 10 million cycles |
| Weight | about 150 g |
Applications
Examples include compressed-air receivers, water-glycol circuits, chilled-water pumps and low-pressure hydraulic returns. Because the cell is ceramic, the part is insensitive to many mild chemicals, and the stainless NPT connection suits typical North American style equipment seen at some Gulf installations.
How HDA 4385-A-0250-000-F1 differs from siblings
Compared with HDA 4385-A-0050-000-F1 the range is five times larger, with overload 725 instead of 150 psi and burst 1000 instead of 250 psi. Compared with the 0500 version it has half the range and one third less overload reserve. All three share thread, plug and seal.
Selection
Match the range to the circuit: 250 psi suits systems with working pressure of about 150 psi. Check fluids for compatibility with FKM. Use the EPDM variant (code E) for refrigerants instead of HDA 4385-A-0250-000-F1.
Installation
Seal and tighten the NPT thread to 40 N·m, fit the plug with its gasket and wire pin 1 to the loop positive and pin 2 to the return. Test with a hand pump at 0 and 250 psi.
Maintenance
Check the plug gasket yearly. If the unit is exposed to freezing water, drain before winter. Replace HDA 4385-A-0250-000-F1 if a zero check shows a persistent offset beyond tolerance.
Practical notes for site teams: the ceramic cell used here is stable against long-term drift, quoted at 0.3 percent of full scale per year typical, which equals about 0.75 psi on a 250 psi range. The plug is supplied, the catalog material number is 908593 and the mating thread is 1/4 NPT. Store spares dry, because moisture inside the connector is a common cause of intermittent signals. For a fast control loop, the rise time of 1 ms or less is more than adequate, and the EMC behaviour is covered by the CE standards EN 61000-6-1 to -4, so no special shielding is needed beyond good practice. Where the transmitter feeds a chart recorder or a historian, set the scaling to 250 psi at 20 mA and confirm the zero by venting the port to atmosphere. A short test log with date and technician name rounds out the record, and the same sheet should list the loop number.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the Hydac HDA 4385-A-0250-000-F1, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Hydac pressure transmitters items can be checked against the bill of materials quickly.
Ordering Checklist for the Hydac HDA 4385-A-0250-000-F1
Before you ask for a quotation for the Hydac HDA 4385-A-0250-000-F1, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the pressure transmitters already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.
Frequently asked questions about HDA 4385-A-0250-000-F1
What overload and burst apply to HDA 4385-A-0250-000-F1? 725 psi overload and 1000 psi burst.
Which thread is on the process side? 1/4-18 NPT male in stainless steel, tightened to 40 N·m.
Is the output 0 to 10 V? No. The A in the code is a 4 to 20 mA two-wire output. 0 to 10 V is code B.
What are the temperature limits? Compensated -13 to 185 degF; fluid -13 to 212 degF with FPM seal; storage -40 to 212 degF.
How do I enquire? Send an RFQ with HDA 4385-A-0250-000-F1, quantity and delivery site.
Documents and quotation
The datasheet for HDA 4385-A-0250-000-F1 is attached to this page. Send an RFQ with HDA 4385-A-0250-000-F1, quantity and destination for availability and lead time.
Datasheets & Documents
- Datasheet Hydac HDA 4385-A-0250-000-F1 Ceramic Pressure Transmitter 250 psi Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac HDA 4385-A-0250-000-F1 Ceramic Pressure
Answers from our engineering team on installation, compatibility and integration.
01What overload and burst apply to HDA 4385-A-0250-000-F1?
The catalog and datasheet give 725 psi overload pressure and 1000 psi burst pressure for this range.
02Which thread is on the process side?
1/4-18 NPT male in stainless steel, tightened to 40 N·m.
03Is the output 0 to 10 V?
No. The A in the code is a 4 to 20 mA two-wire output. 0 to 10 V is code B.
04What are the temperature limits?
Compensated -13 to 185 degF; fluid -13 to 212 degF with FPM seal; storage -40 to 212 degF.
05How do I enquire?
Send an RFQ with HDA 4385-A-0250-000-F1, quantity and delivery site.


















Reviews
There are no reviews yet.