Brand:

Hydac HDA 478G-A-0300-DV-000 Flameproof Transmitter 300 psi

Description

If a purchase order lists HDA 478G-A-0300-DV-000, the plant wants a 300 psi flameproof transmitter that screws into a female NPT port and brings a cable out of a conduit thread. That combination is exactly what this part is. It converts 0 to 300 psi of gauge pressure into 4 to 20 mA and holds a triple hazardous-area approval that includes mining. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Specification overview of HDA 478G-A-0300-DV-000

Parameter Value
Model code HDA 478G-A-0300-DV-000
Material number (catalog) 925071
Measuring range 0 to 300 psi
Overload pressure 1160 psi
Burst pressure 2900 psi
Cell type Vented gauge (V)
Process connection 1/4-18 NPT, male
Tightening torque 30 lb-ft (40 N·m)
Electrical connection 1/2-14 NPT conduit, open-ended cable
Cores / cable 72 in. cable per catalog code; white signal plus, brown signal minus, green and yellow not used
Output 4 to 20 mA, 2-wire, load RLmax = (UB – 8 V) / 20 mA in kOhm
Supply voltage 8 to 30 V DC, residual ripple 5 percent or less, about 25 mA
Accuracy (terminal based) 0.25 percent FS typical and maximum; best-fit line 0.15 percent typical
Non-linearity / hysteresis / repeatability 0.3 / 0.1 / 0.05 percent FS maximum
Temperature coefficient (zero, span) 0.008 percent FS per degC typical, 0.015 maximum
Rise time / long-term drift 1.5 ms or less / 0.1 percent FS per year
Wetted parts Stainless steel 1.4542, 1.4571, 1.4435, 1.4404, 1.4301; FKM seal
Housing / conduit 1.4404 and 1.4435 (316L)
Compensated temperature T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF
Operating and fluid temperature T5: -4 to 176 degF; T6: -4 to 140 degF (FKM seal)
Storage temperature -40 to 212 degF
Protection IP 65 (vented gauge)
Vibration 20 g, 10 to 500 Hz
Weight 0.661 lb (about 300 g)
Approvals ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X

Two numbers help when you review the loop. With a 24 V DC supply the permitted load is (24 V minus 8 V) divided by 20 mA, which gives 800 ohms, enough for a barrier-free flameproof loop with a long cable and a safe-area indicator. And at 300 psi the full-scale accuracy of 0.25 percent equals 0.75 psi, so scaling in the controller should use the real span instead of a rounded figure, and the alarm limits should leave margin for that error band and for the 1 percent loop tolerance of the receiving card. Record the reading at three points of the span during commissioning.

Feature summary of the HDA 478G-A-0300-DV-000

  • Highest range of the vented cell group: 300 psi.
  • Ex d certification in three schemes on a single label.
  • Wiring by flying leads for quick loop connection.
  • Overload reserve of nearly four times the range.
  • Steel parts 1.4542 and 1.4571 at the sensor, 316L housing.
  • Weight 0.661 lb.

Why engineers pick it

This variant is chosen when the process stub is female. Valve-actuation stations, hydraulic power units for drilling drives and shipyard-style test benches in hazardous zones use the 0 to 300 psi span, which is wide enough for charge pressure yet fine enough that a 0.25 percent error equals under one psi. HDA 478G-A-0300-DV-000 therefore replaces a gauge plus a limit switch with a single continuous signal.

How HDA 478G-A-0300-DV-000 differs from nearby codes

Versus 478G-A-0200, the range moves from 200 to 300 psi while overload and burst figures stay at 1160 and 2900 psi. Versus 47F9-A-0300 the thread changes from female to male and the cores change from single wires to flying leads. Versus 477G-A-0300 the thread is NPT instead of SAE 6, and the tightening value is 40 N·m instead of 20 N·m.

Compatibility

The wetted materials suit hydraulic oil, water-glycol and many gases. Avoid media that attack FKM. Match the loop power supply to 8 to 30 V DC and keep the load below (UB minus 8 V) divided by 20 mA. Use cable glands rated for the area of HDA 478G-A-0300-DV-000.

Commissioning

Fit and tighten, connect white to the positive loop terminal and brown to the negative, then confirm 4 mA at zero. With 300 psi applied, expect 20 mA within the 0.25 percent accuracy limit. Capture the result on the loop sheet of HDA 478G-A-0300-DV-000.

Maintenance

Check the cable and the gland once a year and re-verify zero against a reference. Over the stated service life of more than 10 million cycles, drift is limited to 0.1 percent of full scale per year, so recalibration intervals can be long.

Ordering tip

A common mistake is to order the female-thread twin when a male stub is needed. Compare the letters before sending the enquiry for HDA 478G-A-0300-DV-000.

Delivery to Sites in Oman and the GCC

Delivery of the Hydac HDA 478G-A-0300-DV-000 is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive pressure transmitters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Frequently asked questions about HDA 478G-A-0300-DV-000

Is HDA 478G-A-0300-DV-000 a gauge or absolute type? It is a vented gauge type, which the V in the order code states, and the vented cell is offered up to 300 psi.

What is the process thread? It is 1/4-18 NPT male (code 8) with a tightening value of 40 N·m.

What are the overload and burst ratings? The record gives 1160 psi overload and 2900 psi burst; the operating range is 0 to 300 psi.

How many wires carry signal? Two: white is signal plus and brown is signal minus. Green and yellow are not used.

Can it be supplied with an RFQ? Yes. Send the part number HDA 478G-A-0300-DV-000, the required quantity and the destination to Seven Star LLC.

Documents and quotation

The datasheet for HDA 478G-A-0300-DV-000 accompanies this page. Send an RFQ stating HDA 478G-A-0300-DV-000, the quantity and the delivery site, and Seven Star LLC will reply with availability and lead time.

Other Models in the HDA 4700 ExD Range

Seven Star LLC supplies models from the HDA 4700 ExD range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hydac HDA 478G-A-0200-DV-000 Ex d Transmitter, 1/4 NPT MalePressure TransmittersView details
Hydac HDA 478G-A-0300-DV-000 Flameproof Transmitter 300 psiPressure TransmittersYou are viewing this model
Hydac HDA 47FG-A-0200-DV-000 Flameproof Transmitter, Flying LeadsPressure TransmittersView details
Hydac HDA 477G-A-0300-DV-000 SAE-6 Flameproof TransmitterPressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet Hydac HDA 478G-A-0300-DV-000 Flameproof Transmitter 300 psi Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac HDA 478G-A-0300-DV-000 Flameproof Transmitter

Answers from our engineering team on installation, compatibility and integration.

01Is HDA 478G-A-0300-DV-000 a gauge or absolute type?
It is a vented gauge type, which the V in the order code states, and the vented cell is offered up to 300 psi.
02What is the process thread?
It is 1/4-18 NPT male (code 8) with a tightening value of 40 N·m.
03What are the overload and burst ratings?
The record gives 1160 psi overload and 2900 psi burst; the operating range is 0 to 300 psi.
04How many wires carry signal?
Two: white is signal plus and brown is signal minus. Green and yellow are not used.
05Can it be supplied with an RFQ?
Yes. Send the part number HDA 478G-A-0300-DV-000, the required quantity and the destination to Seven Star LLC.