Hydac HDA 8466-A-2000-000 OEM Pressure Transmitter, 2000 psi
Description
A very compact OEM pressure transmitter for mobile hydraulics
The Hydac HDA 8466-A-2000-000(psi) (HYDAC part number 922821) belongs to the HDA 8400 series developed for the OEM market, for example mobile applications. Sensor and pressure connection are stainless steel and welded together, so there is no seal inside the sensor and no internal leakage path. The unit weighs only about 0.12 lb with a stainless steel housing, a 7/16-20 UNF SAE 4 male port and a 4-pole M12 plug.
This code measures 0 to 2000 psi with a 4 to 20 mA output on two conductors, with a typical accuracy of 0.5 percent of full scale.
Technical specifications
| Parameter | Specification |
|---|---|
| HYDAC part number | 922821 |
| Model code | HDA 8466-A-2000-000(psi) |
| Measuring range | 0 to 2000 psi |
| Overload pressure | 2000 psi (catalogue item) |
| Burst pressure | 11600 psi |
| Mechanical connection | SAE 4 male, 7/16-20 UNF 2A; 15 N·m |
| Output signal | 4 to 20 mA, 2 conductor |
| Supply voltage | 8 to 30 V DC |
| Accuracy (DIN 16086) | 0.5 % FS typical |
| Accuracy (BFSL) | 0.25 % FS typical, 0.5 % FS maximum |
| Temperature compensation | 0.015 % FS/°C typical, 0.025 % FS/°C maximum |
| Repeatability / drift | 0.1 % FS / 0.3 % FS per year |
| Rise time | 1.5 ms max. |
| Compensated temperature range | -13 to +185 °F |
| Fluid temperature | -13 to +257 °F |
| Electrical connection | Male M12, 4 pole |
| Protection class | IP 67 |
| Vibration / shock | 25 g / 100 g |
| Wetted parts | Stainless steel, FKM O-ring |
| Approvals as printed | CE; cUL certificate E318391 |
| Weight | 0.12 lb |
What the catalogue and datasheet tell you
The datasheet describes the HDA 8400 as an OEM series with ranges from 0–25 bar to 0–600 bar (roughly 360 to 8700 psi), outputs such as 4 to 20 mA, 0 to 5 V, 1 to 6 V, 0 to 10 V and ratiometric signals, ports in SAE 4, SAE 6 or G1/4 A and many plug options, from M12x1 to Deutsch, AMP and Metri-Pack. This code gives the 2000 psi, 4 to 20 mA, SAE 4 and M12 combination. The catalogue lists an overload of 2000 psi for this item, which differs from the larger overload table in the datasheet, so confirm the overload rating with the supplier. The model-code digits are not decoded in the datasheet text, so state the full code on any order.
Typical use
The small size and the welded stainless steel construction suit mobile machines where space is tight and vibration is high. The datasheet notes ECE type approval for road vehicles and gives vibration resistance of 25 g and shock resistance of 100 g for 6 ms. Make sure the supply stays inside 8 to 30 V DC, use a sealing ring suited to the SAE 4 port, and keep the 15 N·m torque limit.
If the machine already carries an older sensor, compare the port, plug and signal before choosing this unit, because the HDA 8400 offers many combinations and a mismatch is easy to make. Keep a spare for commissioning, as OEM sensors often have lead times.
Because the unit is so small, give it a clear sealing face and keep the connector accessible for service. The ECE type approval named in the datasheet is relevant for road vehicles, so state the application when you enquire in case documentation is needed for approvals.
Documents and quotation
The HDA 8400 datasheet is attached. Please send the full code and the connector you need. See also our pressure instrumentation range.
How the HDA 8466-A-2000-000(psi) works
Like most HYDAC pressure transmitters, the HDA 8400 series is based on a thin-film sensor. A strain gauge bridge is deposited on a stainless steel measuring cell; when system pressure acts on the cell, the bridge resistance changes in proportion to pressure, and the integrated electronics convert this into the output signal. On the HDA 8466-A-2000-000(psi) that signal is a 4 to 20 mA current on two conductors, which is robust against long cable runs and electrical noise. The pressure port contains an orifice to damp pressure peaks.
HYDAC stresses that all parts in contact with the fluid, the sensor and the pressure connection, are stainless steel and welded together, so there are no sealing points inside the sensor and leakage can be excluded. Reverse polarity protection, excess voltage, override and short-circuit protection are provided.
HDA 8400 series data from datasheet E 18.348
| Parameter | Value (series data) |
|---|---|
| Measuring ranges | 25, 40, 60, 100, 160, 250, 400, 600 bar |
| Accuracy to DIN 16086, terminal based | ±0.5 % FS typ., ±1 % FS max. |
| Accuracy, B.F.S.L. | ±0.25 % FS typ., ±0.5 % FS max. |
| Temperature effect, zero and span | ±0.015 % FS/°C typ., ±0.025 % FS/°C max. |
| Rise time | 1.5 ms |
| Long-term drift | ±0.3 % FS typ. per year |
| Operating temperature | –25 to +100 °C (–40 °C on request) |
| Fluid temperature | –25 to +125 °C (–40 °C on request) |
| Vibration resistance | 250 m/s² (5 – 2000 Hz), DIN EN 60068-2-6 |
| Shock resistance | 100 g / 6 ms and 500 g / 1 ms, half sine |
| Protection | IP 65 / IP 67 depending on connector; IP 6K9K to ISO 20653 |
| Current consumption | 22 mA |
| Life expectancy | > 10 million load cycles (0 – 100 % FS) |
| Weight | approx. 55 g |
| 7/16–20 UNF 2A port | Recommended torque 15 N·m, FKM O-ring 8.92 × 1.83 |
| Road approval | E approval available to UN/ECE R10 |
Selection & ordering guide
- Pressure range: choose a range where the normal working pressure is in the upper part of the scale but peaks stay below the overload pressure.
- Output: the series offers 4 – 20 mA, 0 – 5 V, 1 – 6 V, 0 – 10 V and ratiometric 0.5 – 4.5 V at 5 V supply. Code A on this model is the 4 – 20 mA version.
- Port: G1/4 A ISO 1179-2, M14 × 1.5, 9/16–18 UNF (SAE 6) and 7/16–20 UNF (SAE 4) are shown in the datasheet.
- Plug: M12x1, Packard Metri-Pack 150, Deutsch DT04, AMP Superseal, AMP Junior Power Timer or jacketed cable.
- Quantities: HYDAC states the HDA 8400 was developed for OEM customers with minimum order quantities from 500 pieces per type, so check availability for single units of a given code.
Our team can help confirm the correct ordering code for the HDA 8466-A-2000-000(psi) or identify an equivalent HYDAC transmitter for replacement use.
Installation & maintenance
- Fit the transmitter on a clean, undamaged sealing face with the correct FKM O-ring and tighten to the recommended 15 N·m for the 7/16–20 UNF port.
- Use a shielded cable to the M12 connector and keep it away from high-current lines.
- Keep the supply between 8 and 30 V DC and check the loop resistance of the controller input.
- Avoid trapped air and pressure spikes above the overload rating, which can damage the measuring cell.
- Check the zero point periodically; the datasheet gives a typical long-term drift of ±0.3 % FS per year.
Typical applications in Oman & the GCC
HYDAC designed the HDA 8400 for series use, especially mobile applications. In Oman and the GCC the HDA 8466-A-2000-000(psi) suits pressure monitoring on mobile cranes, construction and mining machinery, agricultural equipment, municipal vehicles and compact hydraulic power packs, where high vibration, heat and wash-down conditions are common.
Why source the HDA 8466-A-2000-000(psi) from Seven Star LLC
Seven Star LLC supplies HYDAC pressure transmitters across Oman and the GCC. Send us the full model code, pressure range, port and connector to request a quote, and our team can help confirm the correct ordering code.
Datasheets & Documents
- Datasheet Hydac HDA 8400 OEM pressure transmitter datasheet (E 18.348.2/11.13) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
Related products
Frequently Asked Questions
0 to 2000 psi.
4 to 20 mA on two conductors from an 8 to 30 V DC supply.
SAE 4 male, 7/16-20 UNF 2A, tightened to 15 N·m.
IP 67 with the M12 plug.
Stainless steel with an FKM O-ring.