Brand:

Hydac HDA 4775-A-1000-000 Pressure Transducer 1000 psi, 4-20 mA

Description

Pressure transducers rated at 1000 psi are among the most requested spares in hydraulics, and HDA 4775-A-1000-000 is the Hydac version with the better accuracy class: 0.25 percent of full scale instead of the 0.5 percent of the 4400 line. It has an SAE-6 male port, a 4 to 20 mA output and a supplied DIN 43650 plug. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

The role of HDA 4775-A-1000-000 in a hydraulic loop

With 1000 psi, the overload of 2900 psi and burst of 7250 psi correspond to factors of 2.9 and 7.25. Typical uses include pressure-compensated pump feedback, clamp-force monitoring and filter condition supervision on high-pressure filters rated to 1000 psi. The accuracy keeps the error under 2.5 psi at full scale, so HDA 4775-A-1000-000 suits closed-loop controls that need a repeatable signal. Hysteresis stays below 0.1 percent and repeatability near 0.05 percent.

A word on scaling: configure the controller for 4 mA equal to 0 psi and 20 mA equal to 1000 psi. A reading of 12 mA therefore equals 500 psi. Because the accuracy limit is 0.25 percent of full scale, alarm thresholds should be separated from control set points by at least 2.5 psi to avoid chatter. Keep signal cables away from drive output cables to preserve the excellent EMC behaviour of the instrument.

Feature list

  • Range 1000 psi; overload 2900 psi; burst 7250 psi.
  • Stainless steel measuring cell with thin-film gauge, no internal seals.
  • Rise time 1 ms or less.
  • Shock-free output within 0.1 percent drift per year.
  • EN175301-803 connector supplied, IP 67 mated.
  • Weight about 145 g.

Data table, HDA 4775-A-1000-000

Parameter Value
Model code HDA 4775-A-1000-000
Material number (catalog) 907186
Measuring range 0 to 1000 psi
Overload pressure 2900 psi
Burst pressure 7250 psi
Process connection 9/16-18 UNF 2A male (SAE 6)
Tightening torque 15 lb-ft (20 N·m)
Output signal 4 to 20 mA, 2-wire; load RLmax = (UB – 8 V) / 20 mA in kOhm
Supply voltage 8 to 30 V DC, ripple 5 percent or less
Current consumption 25 mA or less
Accuracy (terminal based) 0.25 percent FS typical and maximum at max. setting
Accuracy (best-fit line) 0.15 percent FS typical, 0.25 percent maximum
Temperature coefficient 0.008 percent FS per degC typical, 0.015 maximum (zero and span)
Non-linearity / hysteresis 0.3 / 0.1 percent FS maximum
Repeatability 0.05 percent FS
Rise time 1 ms or less
Long-term drift 0.1 percent FS per year typical
Electrical connection EN175301-803 (DIN 43650), 3-pole + PE, mating connector supplied
Pins 1 signal +, 2 signal -, 3 not connected, earth = housing
Protection class IP 67 with the mating connector fitted
Wetted parts Stainless steel connection; FKM seal
Compensated temperature -13 to 185 degF
Fluid temperature -13 to 212 degF
Storage temperature -40 to 212 degF
Vibration 20 g, 10 to 500 Hz
Life expectancy more than 10 million cycles, 0 to 100 percent FS
Weight about 145 g

Field applications

Use it on power-pack manifolds, test rigs, pump-testing benches and valve calibration stands. For process plants the unit monitors lube oil headers, injection water lines and seal-oil systems in the non-hazardous parts of the installation. When the installation is classified, use a flameproof sibling instead of HDA 4775-A-1000-000.

How HDA 4775-A-1000-000 differs from the 750 psi and 3000 psi parts

Compared with 0750 the range grows to 1000 psi, overload to 2900 psi and burst to 7250 psi. Compared with HDA 4775-A-3000-000 the range is a third, with overload 7250 psi against 2900 psi. Electrical specification, SAE-6 thread, plug and temperature data are the same across the group, which allows a common spare connector to serve all four.

Selecting the part

Check that normal pressure remains below about 700 psi; if peaks to 2000 psi happen, move to a 3000 psi range. The 24 V loop can carry up to 800 ohms of load. The SAE-6 port requires an O-ring face on the mating block.

Installation

Fit the O-ring, run the thread by hand, tighten the hex to 20 N·m and fit the connector with its gasket. Connect pin 1 to the positive loop terminal and pin 2 to the return. Confirm 4 mA at atmospheric pressure and 20 mA at 1000 psi on HDA 4775-A-1000-000.

Maintenance

The cell is welded and needs no service. Wipe the connector seal and check torque on the screw whenever panels are opened. A mechanical gauge in parallel provides a useful cross-check for HDA 4775-A-1000-000.

Spare-part planning: because 0750, 1000, 3000 and 5000 psi units share the thread, plug and electrical data, a maintenance store can hold one connector type and one O-ring size for the whole group. Record the catalog material number 907186 on the spares list so that a replacement of the 1000 psi range is not confused with its neighbours.

Installation and Commissioning Planning

Planning ahead shortens downtime when a Hydac HDA 4775-A-1000-000 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Hydac equipment can be planned around it.

Typical Questions From Maintenance Teams

Maintenance engineers replacing a Hydac HDA 4775-A-1000-000 usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed pressure transmitters, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.

Frequently asked questions about HDA 4775-A-1000-000

What is the range of HDA 4775-A-1000-000? 0 to 1000 psi, with an overload pressure of 2900 psi and a burst pressure of 7250 psi.

What connector does it have? A male EN175301-803 (DIN 43650) 3-pole plus PE connector, supplied with a mating connector.

Which pins carry the loop? Pin 1 is signal plus, pin 2 is signal minus, pin 3 is not connected and earth is the housing.

What is the typical temperature range? Compensated -13 to 185 degF; fluid -13 to 212 degF.

How do I send an enquiry? Mail an RFQ with HDA 4775-A-1000-000, the number of units and the delivery location.

Documents and quotation

The datasheet of HDA 4775-A-1000-000 is on this page. For prices and lead time send an RFQ with HDA 4775-A-1000-000, quantity and delivery location.

Other Models in the HDA 4700 Range

Seven Star LLC supplies models from the HDA 4700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hydac HDA 4775-A-3000-000 Pressure Transmitter 3000 psi, SAE-6Pressure TransmittersView details
Hydac HDA 4775-A-1000-000 Pressure Transducer 1000 psi, 4-20 mAPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Hydac HDA 4775-A-1000-000 Pressure Transducer 1000 psi, 4-20 mA Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac HDA 4775-A-1000-000 Pressure Transducer 1000

Answers from our engineering team on installation, compatibility and integration.

01What is the range of HDA 4775-A-1000-000?
0 to 1000 psi, with an overload pressure of 2900 psi and a burst pressure of 7250 psi.
02What connector does it have?
A male EN175301-803 (DIN 43650) 3-pole plus PE connector, supplied with a mating connector.
03Which pins carry the loop?
Pin 1 is signal plus, pin 2 is signal minus, pin 3 is not connected and earth is the housing.
04What is the typical temperature range?
Compensated -13 to 185 degF; fluid -13 to 212 degF.
05How do I send an enquiry?
Mail an RFQ with HDA 4775-A-1000-000, the number of units and the delivery location.