Brand:

Hydac EDS 4448-0400-1-PP-000 High-Pressure Electronic Switch 400 bar

Description

The Hydac EDS 4448-0400-1-PP-000 is the 400 bar version of the programmable EDS 4448 pressure switch, designed for presses, pressure intensifiers and test benches that run well above ordinary hydraulic levels. It still uses the standard G1/4 A male port and the 5-pole M12 plug, and it offers one PNP output that can be set to open or close at the programmed point. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Where EDS 4448-0400-1-PP-000 is the right tool

A 400 bar span carries an overload of 800 bar and a burst pressure of 2000 bar. With a set-point step of 1 bar and an accuracy of 1 percent, the instrument resolves about 4 bar at full scale. That is the correct scale for a pressure intensifier output, a high-pressure cleaning pump or a hydraulic tensioner. EDS 4448-0400-1-PP-000 lets a PLC read the pressure condition as a single contact without an analog card.

Resolution deserves a word at this range. A step of 1 bar against a 400 bar span is 0.25 percent of range, finer than the 1 percent accuracy limit, so the grid is never the limiting error. The temperature coefficient of 0.02 percent per degC typical means roughly 0.08 bar per degree at full scale, so a hot cabinet or a cold outdoor skid shifts the reading by only a few bar over the compensated range of minus 25 to plus 85 degC, which is generally acceptable for outdoor skids in Gulf summers.

Features

  • Range 400 bar, overload 800 bar, burst 2000 bar.
  • 1 bar steps for set point and hysteresis.
  • Programmable direction and delays 8 to 2000 ms.
  • Temperature coefficient 0.02 percent FS per degC typical.
  • IP 67, vibration 20 g, shock 100 g.
  • Housing hex 27 mm, weight about 145 g.

Specifications of EDS 4448-0400-1-PP-000

Parameter Value
Model code EDS 4448-0400-1-PP-000
Material number (catalog) 920092
Setting range 0 to 400 bar
Overload pressure 800 bar
Burst pressure 2000 bar
Process connection G1/4 A ISO 1179-2, male
Tightening torque 20 N·m recommended
Wetted parts Stainless steel connection; FKM seal
Switching output 1 PNP transistor output, programmable, N/O or N/C
Switching current 1.2 A maximum with one output
Switch-point increment 1 bar
Switch point / hysteresis window 5 to 100 percent / 1 to 96 percent of range
Delay times 8 to 2000 ms in 8 ms steps (HPG 3000)
Response time 8 ms
Accuracy 1 percent FS maximum; 0.5 percent typical
Temperature coefficient 0.02 percent FS per degC typical, 0.03 maximum
Repeatability 0.1 percent FS maximum
Long-term drift 0.3 percent FS per year typical
Electrical connection M12x1 male, 5-pole
Pins 1 +UB, 2 not connected, 3 0 V, 4 output 1, 5 not connected
Supply voltage 8 to 32 V DC, ripple 5 percent or less
Current consumption 25 mA inactive; 2.025 A total maximum
Switching cycles more than 100 million
Compensated temperature -25 to 85 degC
Storage temperature -40 to 100 degC
Protection class IP 67
Vibration / shock 20 g (10 to 500 Hz) / 100 g (1 ms)
Weight about 145 g
Approvals / EMC CE (EN 61000-6-1/2/3/4); cULus E318391

Typical uses

Typical uses are press-brake hydraulics, injection moulding clamp units, deep-hole drilling pumps and test stands for valves. In Oman the unit supports maintenance of crane and winch hydraulics at ports, where EDS 4448-0400-1-PP-000 replaces a mechanical switch that had drifted.

How EDS 4448-0400-1-PP-000 differs from lower ranges

Its 400 bar range is ten times the 0040 version and four times the 0100 version. Overload and burst are 800 and 2000 bar compared with 80 and 200 bar at 0040. The grid also coarsens from 0.1 bar to 1 bar. For a trip at 30 bar the lower range would resolve better, so do not select EDS 4448-0400-1-PP-000 unless pressures in the upper range are real.

Selection notes

For circuits at 315 bar working pressure with a relief valve at 350 bar, EDS 4448-0400-1-PP-000 gives enough margin. For FKM-incompatible fluids such as some phosphate esters, ask us about the seal. Keep power supply between 8 and 32 V DC.

Installation

Tighten the G1/4 thread to 20 N·m, hold the 27 mm hex only, connect an M12 five-pole plug and program with the HPG 3000. Test with a hand pump up to the set point; avoid sudden shock beyond 100 g.

Maintenance

Yearly verification of both the set point and the direction is enough. If the unit sees frequent pressure peaks near 800 bar, add a damping screw or choose a snubber in the line to protect EDS 4448-0400-1-PP-000.

Documentation: keep the catalog material number 920092 and the programmed values with the equipment file. For high-pressure circuits, many plants also record the date of the last overpressure event; a simple log entry next to the stored set points keeps the history of the unit complete.

Installation and Commissioning Planning

Planning ahead shortens downtime when a Hydac EDS 4448-0400-1-PP-000 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Hydac equipment can be planned around it.

Typical Questions From Maintenance Teams

Maintenance engineers replacing a Hydac EDS 4448-0400-1-PP-000 usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed pressure switches, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.

Frequently asked questions about EDS 4448-0400-1-PP-000

What is the maximum range of the EDS 4448 type in this listing? 0 to 400 bar on EDS 4448-0400-1-PP-000, with 800 bar overload and 2000 bar burst.

How fine is the switch-point step? 1 bar, per the catalog record.

What cable or plug is needed? A 5-pole M12x1 female connector; it is not supplied with the switch.

Which temperature range applies? Compensated -25 to 85 degC, storage -40 to 100 degC.

How can I get a quotation? Send an RFQ naming EDS 4448-0400-1-PP-000, quantity and destination to Seven Star LLC.

Documents and quotation

The datasheet for EDS 4448-0400-1-PP-000 is available on this page. Submit an RFQ with EDS 4448-0400-1-PP-000, quantity and delivery location for availability and lead time.

Other Models in the EDS 4400 Range

Seven Star LLC supplies models from the EDS 4400 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hydac EDS 4448-0250-1-PP-000 Programmable Pressure Switch 250 barPressure SwitchesView details
Hydac EDS 4448-0100-1-PP-000 Electronic Pressure Switch 100 barPressure SwitchesView details
Hydac EDS 4448-0040-1-PP-000 Programmable Pressure Switch 40 barPressure SwitchesView details
Hydac EDS 4448-0400-1-PP-000 High-Pressure Electronic Switch 400 barPressure SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Hydac EDS 4448-0400-1-PP-000 High-Pressure Electronic Switch 400 bar Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac EDS 4448-0400-1-PP-000 High-Pressure

Answers from our engineering team on installation, compatibility and integration.

01What is the maximum range of the EDS 4448 type in this listing?
0 to 400 bar on EDS 4448-0400-1-PP-000, with 800 bar overload and 2000 bar burst.
02How fine is the switch-point step?
The switch-point increment is 1 bar at the 400 bar range, per the catalog record.
03What cable or plug is needed?
A 5-pole M12x1 female connector; it is not supplied with the switch.
04Which temperature range applies?
Compensated -25 to 85 degC, storage -40 to 100 degC.
05How can I get a quotation?
Send an RFQ naming EDS 4448-0400-1-PP-000, quantity and destination to Seven Star LLC.