Brand:

FPA 4100™ UV Digital Photometers

Description

Overview

The FPA 4100™ UV Digital Photometer family enables measurement of the concentration of a wide variety of analytes in both liquid and gas streams. The photonics module can accommodate either UV or visible light sources and features a temperature-controlled photodiode block for maximum signal stability, with the light source and detectors coupled to a measurement cell via fiber optic cables.

As an authorized supplier of Galvanic instrumentation, Seven Star LLC proudly offers the FPA 4100™ to chemical processing plants, refineries, and water treatment facilities across the Sultanate of Oman, Muscat, and the wider GCC. Delivering the utmost in ease-of-operation, precise measurements, and consistent, field-proven performance and value, the FPA 4100™ gives process engineers a versatile photometric measurement platform for both gas and liquid analytical applications.

Measurement Principle

The FPA 4100™ achieves ±2% of full scale accuracy, repeatability, and linearity, with 1% sensitivity and a response time of 30 seconds (T-90). Zero drift is compensated through daily auto-zero, keeping the instrument stable over extended unattended operation periods without requiring reagents or compressed gases for continuous measurement.

Because the light source and detector electronics are isolated from the process and coupled via fiber optic cables to the measurement cell, the FPA 4100™ achieves optimum safety and stability even when analyzing corrosive or hazardous process streams. Multi-stream analysis capability allows a single unit to monitor several process points, reducing the total instrumentation footprint compared with dedicated single-stream photometers.

Engineering Design of the FPA 4100™

The FPA 4100™ controller includes an intuitive user interface with an intrinsically safe, removable keypad, LCD screen, 10 LED indicator lights, and data-logging capability. Auto-calibration using external standards, auto-zero compensation, and digital optimization of detector gains simplify ongoing operation and maintenance, while rugged construction supports continuous industrial deployment.

Measuring 610mm H x 400mm W x 25mm D and weighing 30 kg, the FPA 4100™ operates on either 10-36VDC or 90-240VAC power at 30 watts, with a sample flow of 0.5-1 L/min. The FPA 4100™ series enables remote operation and diagnostics via Ethernet connection, and communicates via Modbus RS232, RS485, and optional TCP/IP protocols for integration with plant control systems.

Key Features

The FPA 4100™ combines flexible photometric measurement with rugged, field-proven construction. Core capabilities include:

  • UV or visible light source options with temperature-controlled photodiode block for signal stability.
  • Multi-stream analysis capability with no reagents or compressed gases required.
  • Auto-calibration using external standards and auto-zero compensation.
  • Fiber-optic coupled measurement cell isolating detector electronics from the process.
  • Intrinsically safe, removable keypad with LCD screen and 10 LED indicator lights.
  • Remote operation and diagnostics via Ethernet connection.
  • Modbus RS232, RS485, and optional TCP/IP communication.
  • CSA Class 1 Division 2, Groups BCD certification, with field certifications available upon request.

Industrial Applications

The FPA 4100™ is well suited to chemical processing, refining, and water treatment applications across Oman requiring precise photometric analyte concentration measurement in gas or liquid streams. Its reagent-free, multi-stream design makes it a cost-effective solution for facilities monitoring multiple process points without the ongoing consumable costs of wet chemistry-based analyzers.

As an authorized supplier of Galvanic instrumentation, Seven Star LLC supports chemical processing plants, refineries, and water treatment operators throughout the Sohar and Salalah economic zones and the broader GCC region with the FPA 4100™’s versatile photometric analysis capability.

Technical Specifications

Full technical parameters for the FPA 4100™ UV digital photometer:

ParameterSpecification
ModelFPA 4100™
Accuracy / Repeatability / Linearity±2% of Full Scale
Sensitivity1% of Full Scale
Response Time30 Seconds (T-90)
Zero/Span Drift±2% F.S. with Daily Auto-Zero
Dimensions610mm H x 400mm W x 25mm D (24″ x 15.8″ x 9.8″)
Weight30 kg (66 lbs)
Power Supply10-36VDC or 90-240VAC, 30 Watts
Sample Flow0.5-1 L/min
CommunicationModbus RS232/RS485, Optional TCP/IP, Ethernet
Relays6 x SPDT, 5 Amp @ 30VDC or 8 Amp @ 120/240VAC
CertificationCSA Class 1 Division 2, Groups BCD; CE

Call To Action

To submit a formal Request for Quote (RFQ), check regional stock availability, or arrange technical consultation for the FPA 4100™ UV Digital Photometer, please contact the official instrumentation division at Seven Star LLC today. As an authorized supplier of Galvanic instrumentation in Oman and the GCC, our engineers are ready to assist with rapid sourcing for your process photometric analysis projects.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “FPA 4100™ UV Digital Photometers”

Your email address will not be published.Required fields are marked *

About brand
Galvanic Applied Sciences is a specialized manufacturer of rugged, high-performance gas and liquid analytical systems engineered specifically for harsh industrial processing environments. At Seven Star LLC, we provide Galvanic's comprehensive portfolio of precise process monitoring instrumentation, including advanced H2S analyzers, spectrophotometers, online titrators, and gas chromatographs. Built to withstand the extreme demands of the natural gas, petrochemical, and refining sectors, these measurement systems deliver real-time, accurate chemical composition data without the delay of manual laboratory sampling. By supplying authentic Galvanic instrumentation, Seven Star LLC enables industries across Oman and the GCC to optimize process yields, ensure environmental compliance, and safeguard critical pipeline infrastructure from highly corrosive media.

Frequently Asked Questions

What types of streams can the FPA 4100 analyze?
The FPA 4100 can measure the concentration of a wide variety of analytes in both liquid and gas streams, using either UV or visible light sources.
Does the FPA 4100 require reagents or compressed gases?
No. The FPA 4100 delivers precise continuous measurement with no reagents or compressed gases required.
How does the FPA 4100 support remote operation?
The FPA 4100 series enables remote operation and diagnostics via an Ethernet connection, alongside Modbus RS232, RS485, and optional TCP/IP communication.
How does the FPA 4100 maintain measurement stability?
The FPA 4100 uses a temperature-controlled photodiode block, daily auto-zero compensation, and auto-calibration using external standards to maintain stable, accurate readings over time.
Is Seven Star LLC an authorized supplier for Galvanic products?
Yes. Seven Star LLC is an authorized supplier of Galvanic Applied Sciences instrumentation in Oman and the GCC, providing genuine products with full support.