Michell CD2-WDC-002 Water Dew-Point Sensor Assembly
Description
Overview
The Michell CD2-WDC-002 is a water dew-point sensor assembly engineered for Michell Instruments’ Condumax II hydrocarbon and water dew-point analyzer platform, a system widely deployed for continuous, automatic natural gas quality monitoring across gas processing, transmission, and custody-transfer applications. The sensor cell integrates a pressure transmitter with the Condumax II’s water dew-point measurement, providing the water dew-point reading that operators need to protect downstream equipment from hydrate formation and condensation damage.
With fast quotation turnaround and technical support, Seven Star LLC proudly supplies the Michell CD2-WDC-002 sensor assembly with part-number traceability and calibration documentation. Gas processing and transmission facilities across Muscat, Sohar, and Salalah can source Michell components through Seven Star LLC with a formal quotation and the manufacturer datasheet.
Measurement Principle
The Michell CD2-WDC-002 works alongside the Condumax II, whose hydrocarbon channel uses the “Dark Spot” direct chilled-mirror measurement principle, in which a precisely temperature-controlled mirror surface is cooled until condensation first begins to form on it, and an optical detection system identifies this exact onset point. The mirror temperature at which condensation first appears is, by definition, the water dew point of the sample gas, giving the Condumax II analyzer a direct, physically fundamental measurement rather than inferred or model-based estimate.
Because the chilled-mirror technique measures the actual phase-change point of the sample rather than relying on a secondary correlation, it delivers long-term accuracy and reliability that other dew-point measurement technologies struggle to match over extended field service. The practical consequence for gas quality engineers is a dew-point reading they can trust for custody-transfer and hydrate-prevention decisions without the recurring recalibration burden associated with less direct measurement methods.
Engineering Design of the Michell CD2-WDC-002
The Michell CD2-WDC-002 combines the water dew-point sensor cell with an integrated pressure transmitter, allowing the Condumax II analyzer to reference dew-point readings against the actual sample pressure for accurate correction to standard reference conditions. This integrated pressure-referencing capability is essential for natural gas quality reporting, since dew point varies directly with operating pressure and must be normalized for consistent, comparable readings across changing pipeline conditions.
The sensor assembly is designed as a field-serviceable component of the broader Condumax II system, allowing maintenance teams to exchange the sensor cell during scheduled service without needing to replace the full analyzer chassis. This modular design philosophy reduces both the cost and downtime associated with maintaining accurate, continuous dew-point monitoring on critical gas quality measurement points.
Key Features
The Michell CD2-WDC-002 combines fundamental chilled-mirror measurement with practical field serviceability, and the following features summarize why gas quality engineers specify Condumax II sensor assemblies for critical monitoring points:
- Direct “Dark Spot” chilled-mirror measurement provides a physically fundamental dew-point reading rather than inferred estimate.
- Integrated pressure transmitter allows accurate correction of dew-point readings to standard reference conditions.
- Field-serviceable modular design reduces maintenance downtime compared to full analyzer replacement.
- Long-term measurement stability minimizes recalibration frequency on continuous monitoring installations.
- Purpose-built for integration with the established Condumax II analyzer platform.
- Supports both hydrocarbon and water dew-point monitoring requirements in natural gas quality programs.
- Proven technology base with an established track record in custody-transfer gas quality applications.
- Genuine Michell manufacturing ensures consistent performance matched to the analyzer’s calibration.
Industrial Applications
The Michell CD2-WDC-002 supports continuous water dew-point monitoring at natural gas processing plants, pipeline custody-transfer metering stations, and gas transmission compressor stations where hydrate prevention and gas quality compliance depend on accurate, continuous measurement. In Oman, Condumax II-based dew-point monitoring is widely deployed across the country’s gas processing and export infrastructure to protect pipelines and downstream equipment from condensation and hydrate-related damage.
With engineering support in Muscat, Seven Star LLC supplies sensor assemblies and Condumax II components on request to gas processing operators and instrumentation contractors throughout the Sohar and Salalah economic zones, supporting both new analyzer projects and sensor cell replacement on existing installations across Muscat. Reliable dew-point measurement is a critical safeguard for the GCC’s natural gas transmission and processing infrastructure.
Technical Specifications
The table below summarizes the key parameters of the Michell CD2-WDC-002 water dew-point sensor assembly.
| Parameter | Specification |
|---|---|
| Model | Michell CD2-WDC-002 |
| Function | Water dew-point sensor assembly |
| Measurement Principle | Direct chilled-mirror (“Dark Spot”) |
| Integrated Component | Pressure transmitter for reading correction |
| Compatible System | Michell Condumax II analyzer platform |
| Serviceability | Field-exchangeable sensor cell |
| Application | Natural gas water dew-point and quality monitoring |
Why Choose Seven Star LLC for Michell Water Dew-Point Sensors
A dew-point sensor assembly’s measuring range and process connection have to be matched to your actual gas drying or moisture monitoring application, since a sensor calibrated for a very dry gas stream performs poorly at higher moisture levels, and vice versa. Seven Star LLC confirms the correct CD2-WDC-002 configuration against your specific application and process connection before order confirmation, drawing on our trusted Michell Instruments suppliership across Oman and the wider GCC. We also support gas processing and compressed air facilities across Muscat, Sohar, and Salalah with recalibration scheduling and traceable certificate management, keeping moisture measurement points defensible for both process control and quality documentation purposes.
Request a Quote for Michell CD2-WDC-002 Water Dew-Point Sensor Assembly
Seven Star LLC supports formal RFQ submissions, confirms lead time at quotation, and can provide the full technical datasheet for the Michell CD2-WDC-002 sensor assembly on request. Contact the Seven Star LLC instrumentation division for genuine Michell gas quality analyzers and application engineering support across Muscat, Sohar, and Salalah.
Related Products
- Southland Sensing OMD-625 Oxygen Analyzer
- Servomex SERVOPRO NanoTrace DF-550E Ultra-Trace Oxygen Analyzer
- FPA 4100™ UV Digital Photometers
- Systech ZR810 Zirconia Oxygen Analyzer — O2 in Argon + Hydrogen (≤3%), 0-10/100/1000ppm
- Teledyne 8800B Trace Moisture Analyzer – 8800 Series
- MSA Chillgard 5000 Refrigerant Monitor
- Applied Analytics OMA Odorant Analyzer
Datasheets & Documents
- Instruction Manual Michell CD2-WDC-002 Water Dew-Point Sensor Assembly Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moisture in gas is a small number with large consequences, and measuring it has been the work of Michell Instruments since 1974. Based in Ely, United Kingdom, the company makes dew-point transmitters, hygrometers and process analyzers for moisture, hydrocarbon dew point and oxygen.
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
Related products
Frequently Asked Questions
It is a direct chilled-mirror technique in which a mirror is cooled until condensation first forms, and an optical system detects that exact onset point, giving a physically fundamental dew-point reading rather than inferred estimate.
Dew point varies with sample pressure, so the integrated transmitter allows the Condumax II analyzer to correct readings to standard reference conditions for accurate, comparable gas quality reporting.
Yes. The CD2-WDC-002 is designed as a field-serviceable, modular component of the Condumax II system, so maintenance teams can exchange the sensor cell during scheduled service without full chassis replacement.
Natural gas processing, pipeline custody-transfer metering, and transmission compressor stations rely on this measurement to protect equipment from hydrate formation and to verify gas quality compliance.
Yes. Seven Star LLC is an experienced supplier of Michell in Oman and the GCC, supplying genuine gas quality analyzers and sensor assemblies with part-number traceability.

Reviews
There are no reviews yet.