- Vibration Monitoring
- PLC & I/O Cards
- Industrial Communications
- Automation Accessories
- Controllers & Data Acquisition
- AC Drives
- Isolator & Barrier
- Industrial Computers
- Encoders
- Automation Software
- Safety Switches & Guard Locking
- HMI Displays
- Motor Soft Starters
- Servo Drives
- CCTV & Security
- Robotics
- Machine Vision
- Pneumatic Cylinders
Southland Sensing Ltd.
Southland Sensing Ltd. builds oxygen analyzers around oxygen sensors it makes in house, for trace and percent measurement. The analyzers carry the OMD name and come as portable units and as online instruments for panels and process lines. Seven Star LLC lists Southland Sensing oxygen analyzers from the OMD series and supplies them, with replacement sensors, to gas plants, laboratories and process users in Oman.
Read more about Southland Sensing Ltd. ↓ Brand profile
About Southland Sensing Ltd.
- Founded
- 2013
- Headquarters
- Ontario, USA
- Speciality
- Electrochemical oxygen sensors
- Listed with us
- 5 products
Southland Sensing Ltd. products by category
Southland Sensing Ltd. builds oxygen analyzers around oxygen sensors it makes in house, for trace and percent measurement. The analyzers carry the OMD name and come as portable units and as online instruments for panels and process lines.
Seven Star LLC lists Southland Sensing oxygen analyzers from the OMD series and supplies them, with replacement sensors, to gas plants, laboratories and process users in Oman.
Southland Sensing OMD analyzers listed here
Five OMD models are on this page:
- OMD-21: portable percent oxygen analyzer
- OMD-501X: 1/4 DIN panel mount analyzer with a remote sensor housing
- OMD-625: online process analyzer for hazardous areas
- OMD-677: online analyzer with ppm and percent ranges
- OMD-190: oxygen analyzer
The measuring range and the sensor are part of the order, so state both with the OMD number.
Where Southland Sensing oxygen analyzers are used
The manufacturer names industrial gas and PSA plants, semiconductor manufacturing, natural gas, biogas monitoring and aerospace among its applications. Typical tasks are checking the purity of nitrogen and other inert gases, watching blanketing and purging, and monitoring glove boxes. Portable units serve spot checks, and online units stay on a sample line. Background gases matter: a stream that carries carbon dioxide or hydrogen sulfide needs a sensor suited to it, which is a frequent question from GCC gas processing sites.
Ordering Southland Sensing analyzers and sensors: what we need
Send the analyzer model and serial number, and for a sensor the type printed on the sensor label. For a new analyzer, tell us the measuring range you need, the background gas composition, the sample pressure and temperature, whether the unit must be portable or fixed, the power supply available, the outputs and alarms required, and the area classification of the mounting location. With this we check the sensor and analyzer selection against the manufacturer documentation. A sensor is a consumable with a limited life, so tell us if a spare sensor should be included.
Request a Quote for Southland Sensing Ltd. Products
Looking for Southland Sensing Ltd. parts not listed here, or pricing for a project? Send us the part numbers and quantities. Seven Star LLC sources genuine Southland Sensing Ltd. products for customers across Oman and the GCC and replies with a formal quotation.
- Genuine OEM products
- Supply across Oman & the GCC
- Formal quotation from our sales team
Free, no-obligation quotation · takes about 1 minute
Other enquiries: [email protected] · WhatsApp
Frequently Asked Questions
Decide first between portable and online use, then state the measuring range, trace or percent, and the gas you are measuring in. Say whether the unit goes in a panel, on a sample line or in a classified area. Send those requirements and we will check the manufacturer documentation for the matching OMD model and sensor.
Read the sensor type and serial number from the label on the sensor body, and the model and serial number of the analyzer. Sensors for trace and percent measurement, and for acid gas backgrounds, are different types. Fitting the wrong one gives wrong readings, so the label data is essential.
Yes, it can. Galvanic oxygen sensors behave differently in inert backgrounds and in streams that contain acid gases such as carbon dioxide or hydrogen sulfide. Give the full gas composition in your inquiry, including minor components, so the sensor type can be checked against the manufacturer selection guidance before the order is placed.
That depends on the model and its certification. Among the models listed here, the OMD-625 is the one described as an online process analyzer for hazardous areas. State the area classification of the location in your inquiry, and we provide the certificate the manufacturer issues for that version, on request. Do not assume a general-purpose model can be used.
No. Seven Star LLC is an independent industrial supplier based in Muscat. We source Southland Sensing oxygen analyzers and sensors through commercial channels, check the model or order code against the manufacturer's documentation before quoting, and provide the manufacturer's datasheet and the certificates the manufacturer issues with the order on request.