- Automation & ControlView all 2,317 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Fluke
Fluke Ti401 PRO 640 x 480 Infrared Camera
Description
Ti401 PRO 640 x 480 infrared camera with LaserSharp focus
The Fluke Ti401 PRO is a pistol-grip thermal imager for industrial maintenance teams who need a full 640 x 480 detector without paying for the extra functions of the top-of-range models. It sits at the entry point of the PRO series, below the Ti480 PRO, and is built around the same optics, the same laser-assisted focus and the same wireless workflow. Seven Star LLC supplies the Ti401 PRO in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
The model name is simple, but the ordering information adds one choice that matters: the camera is listed in a 60 Hz version and a 9 Hz version. Both use the same 307,200-pixel detector; the frame rate is the only difference listed in the datasheet.
| Element | Value | Meaning |
|---|---|---|
| Ti401 | Series designation | Four-hundred class, 640 x 480 pixel detector |
| PRO | Product line | Professional industrial range with LaserSharp Auto Focus and Smart Lens support |
| 60 Hz / 9 Hz | Frame rate version | Chosen at ordering; same detector and optics |
| FLK-Ti401 PRO | Ordering prefix | Used in the manufacturer ordering list |
Ti401 PRO technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / Ti401 PRO |
| Infrared resolution | 640 x 480 (307,200 pixels) |
| Spatial resolution (IFOV), standard lens | 0.93 mRad, D:S 1065:1 |
| Field of view | 34 ° H x 24 ° V |
| Minimum focus distance | 15 cm (approx. 6 in) |
| Focus | LaserSharp Auto Focus with built-in laser distance meter; advanced manual focus |
| Thermal sensitivity (NETD) | ≤ 0.075 °C at 30 °C target (75 mK) |
| Temperature range | -20 °C to +650 °C (not calibrated below -10 °C) |
| Accuracy | ±2 °C or 2 % at 25 °C nominal, whichever is greater |
| Spectral band | 7.5 µm to 14 µm (long wave) |
| Display | 3.5 in landscape touchscreen, 640 x 480 LCD |
| Visible camera | 5 MP built-in, with IR-Fusion |
| Frame rate | 60 Hz or 9 Hz versions |
| Memory | Removable 4 GB micro SD, 4 GB internal flash, USB flash drive saving |
| Battery | Two field-replaceable lithium-ion smart packs, 2 to 3 hours each, 2.5 hours charge |
| Operating / storage temperature | -10 °C to +50 °C / -20 °C to +50 °C without batteries |
| Enclosure / drop | IP54; engineered to withstand a 2 m drop with standard lens |
| Size / weight | 27.7 x 12.2 x 16.7 cm / 1.04 kg with battery |
| Warranty | Two years standard |
How the Ti401 PRO produces a focused, measurable image
A thermal image is only useful if the target is in focus, because defocus averages the temperature of a hot connection with its cool surroundings and understates the fault. The Ti401 PRO addresses this with a laser distance meter that measures the range to the point you aim at and drives the lens to the matching focus position. The distance is shown on screen, which also helps when the same inspection route is repeated months later from the same standing position.
The detector registers long-wave infrared between 7.5 µm and 14 µm. The camera converts radiation to temperature using on-screen corrections for emissivity (value or material table), reflected background temperature and transmission, so that bare copper, painted steel and insulating covers can each be set up correctly. IR-Fusion blends the 5 MP visible image with the thermal image so that a hot spot can be tied to a recognisable component, label or terminal.
Where the Ti401 PRO fits in the Fluke thermal range
The Ti401 PRO shares its 640 x 480 detector with the Ti480 PRO, TiX501 and TiX580. What changes between them is the feature set. Compared with the Ti480 PRO and TiX580, the Ti401 PRO has no digital zoom, no video recording, no line temperature graph, no auto capture and no user-definable spot markers, and its measurement ceiling is 650 °C rather than 1,000 °C. In return it is the lightest of the group at 1.04 kg and keeps the one-handed pistol-grip form. The cameras below the PRO line, such as the Ti300+ at 320 x 240 and the TiS series, use smaller detectors.
| Model | Detector | Max range | Display | Digital zoom | NETD |
|---|---|---|---|---|---|
| Ti401 PRO | 640 x 480 | 650 °C | 3.5 in | No | 75 mK |
| Ti480 PRO | 640 x 480 | 1,000 °C | 3.5 in | Yes, 2x and 4x | 50 mK |
| TiX501 | 640 x 480 | 650 °C | 5.7 in articulating | Yes, 2x | 75 mK |
| TiX580 | 640 x 480 | 1,000 °C | 5.7 in articulating | Yes, 2x/4x/8x | 50 mK |
Selecting the Ti401 PRO and its accessories
- Confirm that a 650 °C ceiling covers your hottest target; furnace, kiln or steam-line work may need a 1,000 °C model.
- Choose 60 Hz when you scan moving or vibrating machinery; a 9 Hz version is available where the frame rate is not needed.
- Decide on lenses: the optional 2x telephoto, 4x telephoto, wide-angle and 25 micron macro Smart Lenses need no calibration after fitting.
- Plan spare batteries; each pack gives 2 to 3 hours, and the two-bay charger shortens turnaround.
- Check software needs: the free desktop software exports to BMP, GIF, JPEG, PNG and TIFF.
Installation, commissioning and maintenance of the Ti401 PRO
The Ti401 PRO needs no installation. On first use set the language, date, emissivity default and temperature unit, and insert the micro SD card. Charge both batteries before the first inspection, because smart batteries show their state of charge on a five-segment display. The manufacturer recommends a two-year calibration cycle under normal operation, so plan a verification before the second year if the images feed compliance records. Keep the germanium lens clean with a soft cloth and lens-safe solution only; abrasive wiping damages the coating. Store the camera in the supplied hard case with the batteries removed if it will sit unused for long periods.
Operating temperature is -10 °C to +50 °C. In summer plant areas of the Gulf, a camera left in a vehicle can exceed that limit, so keep it in the cab or in shade and let it settle before use.
Typical applications of the Ti401 PRO in Oman and the GCC
In oil and gas facilities the camera is used to scan motor control centres, switchgear, transformer bushings and cable terminations while equipment is loaded. In power and desalination plants it finds hot bearings, overloaded phases and blocked heat exchanger passes. Petrochemical sites use it to check insulation damage on hot piping and refractory condition on small heaters within the 650 °C range. In hot, dusty and humid conditions the IP54 enclosure and removable memory card keep the routine simple, and the laser-assisted focus lets inspectors keep a safe distance from live panels.
Information to send with an RFQ for the Ti401 PRO
- Part number Ti401 PRO and the required frame rate (60 Hz or 9 Hz)
- Quantity and any optional lenses, extra batteries, charger or car adapter
- Typical target temperatures and working distances
- Delivery location in Oman or the GCC and required lead time
- Whether calibration documents or an extended warranty are required
Documents and quotation
A datasheet for the Ti401 PRO is attached on this page. It covers the Ti401 PRO together with the Ti480 PRO, TiX501 and TiX580, so compare the columns carefully.
Send us the part number Ti401 PRO, the frame rate and the quantity, and we will respond with availability and a quotation.
Other Models in the Fluke Pro Thermal Range
Seven Star LLC supplies models from the Fluke Pro Thermal range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Fluke Ti401 PRO 640 x 480 Infrared Camera | Portable Test & Measurement | You are viewing this model |
| Fluke TiX580 Infrared Camera, 640 x 480, 1000 C | Portable Test & Measurement | View details |
Datasheets & Documents
- Datasheet Fluke Ti401 PRO Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke Ti401 PRO 640 x 480 Infrared Camera
Answers from our engineering team on installation, compatibility and integration.
01What is the detector resolution of the Fluke Ti401 PRO?
The Ti401 PRO uses a 640 x 480 detector, which gives 307,200 pixels. With the standard lens the spatial resolution is 0.93 mRad and the field of view is 34 degrees by 24 degrees.
02What is the maximum temperature the Ti401 PRO can measure?
The measurement range is -20 °C to +650 °C, and it is not calibrated below -10 °C. Models that reach 1,000 °C in the same series are the Ti480 PRO and TiX580.
03Does the Ti401 PRO record video or have digital zoom?
No. According to the combined datasheet the Ti401 PRO has neither video recording nor digital zoom. It captures still images in bmp, jpeg and is2 formats.
04Can lenses be changed on the Ti401 PRO?
Yes. Optional Smart Lenses include a 2x telephoto, a 4x telephoto, a wide-angle and a 25 micron macro lens. They need no calibration after fitting.
05How long does a Ti401 PRO battery last?
Each of the two lithium-ion smart batteries gives about 2 to 3 hours depending on settings and use. A full charge takes about 2.5 hours in the charger or in the camera.


















Reviews
There are no reviews yet.