Brand:

Fluke Ti300+ Thermal Imager, 320 x 240, 650 C

Description

Ti300+ 320 x 240 thermal imager with LaserSharp Auto Focus

The Fluke Ti300+ is a pistol-grip thermal imager for maintenance technicians who want laser-assisted focus and interchangeable lenses on a 320 x 240 detector. It is a step up from the fixed-focus TiS range, because the focus is set from a measured target distance rather than by eye, and it is a step below the 640 x 480 PRO cameras in resolution and feature count. Seven Star LLC supplies the Ti300+ in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The manufacturer lists the Ti300+ as FLK-Ti300+ 60 Hz and FLK-Ti300+ 9 Hz. The plus sign marks the current generation of the Ti300 and is part of the model name, so keep it when you quote or search.

Ti300+ technical specifications

Parameter Specification
Manufacturer / part number Fluke / Ti300+
Infrared resolution 320 x 240 (76,800 pixels)
Spatial resolution (IFOV) 1.85 mRad, D:S 532:1 with standard lens
Field of view 34 ° H x 24 ° V
Minimum focus distance 15 cm (approx. 6 in)
Focus LaserSharp Auto Focus with laser distance meter; advanced manual focus
Thermal sensitivity (NETD) ≤ 0.075 °C at 30 °C target (75 mK), best possible
Temperature range -20 °C to +650 °C (not calibrated below -10 °C)
Accuracy ±2 °C or 2 % at 25 °C nominal, whichever is greater
Spectral band 7.5 µm to 14 µm
Display 3.5 in landscape touchscreen, 640 x 480 LCD
Visible camera / frame rate 5 MP / 60 Hz or 9 Hz versions
Digital zoom / video No / No
Memory Removable 4 GB micro SD, 4 GB internal flash, USB flash drive saving
Image formats bmp, jpeg, is2
Battery Two lithium-ion smart packs, 2 to 3 hours each, 2.5 hours charge
Operating / storage -10 °C to +50 °C / -20 °C to +50 °C without batteries
Enclosure / drop IP54 / 2 m with standard lens
Size / weight 27.7 x 12.2 x 16.7 cm / 1.04 kg with battery
Warranty / calibration cycle Two years standard / two years recommended

How LaserSharp focus helps the Ti300+ user

Passive autofocus in thermal cameras tends to lock onto whatever has the most contrast, which in a switchgear room can be a nearby cable tray rather than the intended lug. LaserSharp points a laser at the exact target, reads the distance and sets the lens. The same distance is shown on the screen, so an inspector can repeat the shot at a similar range on the next route. The datasheet also notes that the system can image through common obstacles such as chain-link fences, which is practical at outdoor transformer yards.

Where the Ti300+ sits among Fluke thermal cameras

With a 1.85 mRad IFOV, the Ti300+ resolves a target about 1.85 mm across per metre of distance, which is roughly twice the pixel size of the 640 x 480 PRO models. Use it for panels, motors and piping inspected at a few metres. Move to the Ti401 PRO or TiX580 when you need to see small targets from much further away. The TiS60+ gives the same 320 x 240 detector but with fixed focus, 400 °C range and 45 mK sensitivity, while the Ti300+ adds laser focus, lens options and a 650 °C range.

Model Detector Focus Max range Optics
Ti300+ 320 x 240 LaserSharp 650 °C Smart Lens support
TiS60+ 320 x 240 Fixed focus 400 °C No interchange
Ti401 PRO 640 x 480 LaserSharp 650 °C Smart Lens support
TiS75+ 384 x 288 Manual focus 550 °C No interchange

Image files from the Ti300+ can be reviewed on the camera by thumbnail or full screen, and the desktop software exports them to bitmap, GIF, JPEG, PNG or TIFF. Voice annotations of up to 60 seconds and two IR-PhotoNotes can be attached to each image, which helps when a long route covers dozens of similar panels.

Selecting and ordering the Ti300+

  • Decide whether 320 x 240 resolution is enough for your typical working distance.
  • Specify 60 Hz or 9 Hz at ordering.
  • Add optional Smart Lenses: 2x telephoto, 4x telephoto, wide-angle or 25 micron macro.
  • Order spare batteries and the car charger if inspections run a full shift.
  • Remember it has no video recording, digital zoom or auto capture; choose a higher model if you need them.

Commissioning and maintenance of the Ti300+

Set date, language, emissivity default and temperature units, then insert the micro SD card. Check focus on a known target, and keep the lens free of fingerprints and dust. The manufacturer recommends a two-year calibration cycle, which suits the camera used in normal service. Charge the two batteries ahead of each inspection day and rotate them. Because operating temperature is limited to +50 °C, do not leave the Ti300+ on a vehicle dashboard in summer.

Typical applications of the Ti300+ in Oman and the GCC

Technicians use the Ti300+ for electrical panels, motor terminal boxes, bearings, steam lines and heat exchangers in oil and gas, power, water and petrochemical facilities. Its 650 °C ceiling covers most process surfaces below furnace level. IP54 sealing and one-handed operation suit dusty plants, and the distance readout supports consistent route-based inspections across large sites.

Information to send with an RFQ for the Ti300+

  • Part number Ti300+ and frame rate (60 Hz or 9 Hz)
  • Quantity and optional lenses, batteries or charger
  • Targets, temperatures and typical distances
  • Delivery location and time frame
  • Calibration certificate or warranty extension needs

Storage, handling and spares for the Fluke Ti300+

Keep the Fluke Ti300+ in its carrying case when it is not in use, and store it in a clean, dry place. Remove or charge the batteries as recommended in the user manual before long storage. Field teams in Oman and the GCC should avoid leaving the instrument in a vehicle in the sun, as high cabin temperatures can exceed the storage range and shorten battery life.

  • Check the instrument, cables, hoses or lenses for damage before each job.
  • Clean the unit with a soft, slightly damp cloth only; do not use solvents unless the manual allows them.
  • Plan a calibration interval that matches your quality system, and keep the calibration certificate with the asset record.
  • Order wear parts and accessories, such as batteries, test leads, hoses or adapters, together with the instrument.

For calibration and test work, it helps to state in your RFQ whether you need an accredited calibration certificate with the Fluke Ti300+, so the right documents can be confirmed with the quotation.

Documents and quotation

A datasheet for the Ti300+ is attached on this page.

Send us the part number Ti300+, the frame rate and the quantity and we will reply with availability and a quotation.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke Ti300+ Thermal Imager, 320 x 240, 650 C

Answers from our engineering team on installation, compatibility and integration.

01What resolution does the Fluke Ti300+ have?
The Ti300+ uses a 320 x 240 detector with 76,800 pixels. The standard lens gives an IFOV of 1.85 mRad and a 34 by 24 degree field of view.
02Does the Ti300+ have automatic focus?
Yes. LaserSharp Auto Focus measures the distance to the target with a laser and sets the lens. Advanced manual focus is also provided when you want to override it.
03What is the temperature range of the Ti300+?
It measures from -20 °C to +650 °C and is not calibrated below -10 °C. Accuracy is the greater of 2 °C or 2 % at 25 °C nominal.
04Can the Ti300+ record video?
No. The datasheet lists no video recording, no digital zoom and no auto capture for this model. It saves still images in bmp, jpeg and is2 formats.
05Which lenses can be used on the Ti300+?
Optional Smart Lenses are a 2x telephoto, a 4x telephoto, a wide-angle and a 25 micron macro lens. They do not require calibration when fitted.