Brand:

Fluke 5522A Multi-Product Calibrator

Description

Overview

Fluke 5522A is the flagship multi-product calibrator in Fluke’s mid-range calibration lineup, extending the electrical and temperature coverage of the 5502A with pressure calibration support and a substantially higher-bandwidth oscilloscope calibration option. Beyond sourcing DC/AC voltage to ±1020V, current to 20.5A, resistance to 1100 MΩ, and capacitance to 110 mF, the Fluke 5522A interfaces directly with Fluke 700Pxx pressure modules, letting a single calibration platform cover electrical, temperature, and pressure verification for process instrumentation technicians who would otherwise need three separate reference instruments.

Backed by manufacturer datasheet documentation, Seven Star LLC proudly supplies the Fluke 5522A to advanced calibration laboratories and process instrumentation divisions across Oman and the GCC, backed by genuine factory support, technical application guidance, and Fluke’s GPIB/RS-232 automation ecosystem for labs running multi-discipline calibration programs.

Operating Principle

The Fluke 5522A generates its electrical outputs from a precision internal reference with closed-loop feedback regulation, while a dedicated pressure interface reads and controls connected 700Pxx pressure modules directly from the calibrator’s front panel, unifying pressure, electrical, and temperature calibration under one operator workflow and one traceability record. Thermocouple simulation across eleven types (B, C, E, J, K, L, N, R, S, T, U) resolves to 10 µV/°C with automatic cold-junction compensation, and RTD sourcing spans multiple Pt385 and Cu configurations, giving the instrument the temperature-function depth that process calibration technicians require for transmitter verification.

For power-quality and oscilloscope work, the 5522A offers phase lock with frequency uncertainty below 2.5 ppm, and harmonic and flicker simulation with the power quality option, plus an optional oscilloscope calibration path extending to 600 MHz or 1.1 GHz, with edge rise times under 300 picoseconds on the 1.1 GHz option — bandwidth well beyond what the 5502A offers. Reverse power protection and immediate output disconnection or fuse protection on the output terminals, rated to ±300V peak, protect the reference circuitry from accidental miswiring during multi-function test sequences, a practical safeguard in busy calibration labs handling many different instrument types in a single shift.

Engineering Design of the Fluke 5522A

The Fluke 5522A is housed in a rack-mountable bench enclosure with dual alphanumeric displays, dedicated function keys, and a numeric keypad with rotary knob for fast value entry across its wide function set. Front-panel terminals separate normal voltage/current binding posts from auxiliary sense connections, a guard terminal for high-resistance measurements, a dedicated thermocouple/RTD block, and a scope-output BNC connector feeding the optional high-bandwidth oscilloscope calibration path.

A pressure module interface accepts Fluke 700Pxx series pressure modules directly, so a technician swaps in the correct pressure range module for a given calibration job without needing an entirely separate pressure calibrator on the bench. RS-232 and IEEE 488 (GPIB) interfaces are provided as standard for integration with MET/CAL or a laboratory’s own automated calibration procedures, and the instrument’s phase-locking capability supports advanced harmonic and flicker test sequences run under program control.

Key Features

The Fluke 5522A combines electrical, temperature, and pressure calibration with advanced oscilloscope and power-quality functions. Its principal capabilities include:

  • Sources DC voltage to ±1020V and AC voltage from 1 mV to 1020V across 10 Hz to 500 kHz for wideband voltmeter calibration.
  • Delivers DC and AC current to 20.5A across 10 Hz to 30 kHz for clamp meter and current transducer verification.
  • Generates resistance to 1100 MΩ and capacitance from 220 pF to 110 mF for ohmmeter and capacitance meter checks.
  • Simulates eleven thermocouple types at 10 µV/°C resolution and multiple Pt385/Cu RTD configurations for temperature transmitter calibration.
  • Interfaces directly with Fluke 700Pxx pressure modules, adding pressure calibration to the same platform without a separate instrument.
  • Offers optional 600 MHz or 1.1 GHz oscilloscope calibration, with edge rise times under 300 picoseconds on the 1.1 GHz option.
  • Provides phase lock with frequency uncertainty below 2.5 ppm; composite harmonic and flicker simulation are available with the power quality option.
  • Protects output terminals with reverse power protection, immediate disconnection, and fuse protection to ±300V peak against miswiring.

Industrial Applications

Across Oman’s oil and gas, petrochemical, and power generation sectors, advanced calibration laboratories rely on the Fluke 5522A to consolidate electrical, temperature, and pressure verification onto a single accredited reference platform, reducing the number of separate calibrators a lab must maintain traceability records for. Its 700Pxx pressure module compatibility makes it especially valuable to process instrumentation teams servicing pressure transmitters, switches, and gauges alongside electrical and temperature instrumentation during plant turnarounds. Refineries, LNG facilities, and desalination plants in the Sohar and Salalah free zones, where process safety depends on accurately calibrated pressure and temperature loops, depend on this class of multi-discipline reference standard to keep field instrumentation within traceable calibration between major maintenance windows.

Working closely with plant engineers in the region, Seven Star LLC distributes the Fluke 5522A to advanced calibration laboratories and industrial end users throughout the Sultanate of Oman, Muscat, and the wider GCC, supporting hospital biomedical engineering teams, semiconductor and electronics manufacturers, and district cooling operators that all require multi-discipline calibration accuracy in a single accredited instrument. Seven Star LLC’s technical support helps calibration teams in Sohar, Salalah, and Muscat specify and source a 5522A, with lead time confirmed at quotation.

Technical Specifications

The table below summarizes the primary specifications of the Fluke 5522A relevant to advanced calibration laboratory procurement.

Parameter Specification
Model Fluke 5522A
DC Voltage 0 to ±1020V
AC Voltage 1 mV to 1020V, 10 Hz–500 kHz
DC Current 0 to 20.5A
AC Current 29 µA to 20.5A, 10 Hz–30 kHz
Resistance 0 to 1100 MΩ
Capacitance 220 pF to 110 mF
Thermocouple Types B, C, E, J, K, L, N, R, S, T, U (10 µV/°C)
RTD Types Pt385, Cu configurations
Pressure Modules Fluke 700Pxx series (interfaced)
Oscilloscope Calibration (optional) 600 MHz or 1.1 GHz options; edge rise time under 300 ps (1.1 GHz option)
Phase-Lock Frequency Uncertainty <2.5 ppm
Output Protection Reverse power, disconnect/fuse to ±300V peak
Interfaces RS-232, IEEE 488 (GPIB)

Request a Quote for Fluke 5522A Multi-Product Calibrator

Seven Star LLC invites advanced calibration laboratories and process instrumentation divisions across Oman and the GCC to submit a formal RFQ for the Fluke 5522A Multi-Product Calibrator. With fast quotation turnaround and technical support, Seven Star LLC supplies on request with lead time confirmed at quotation, provides the full technical datasheet on request, and connects buyers directly with its instrumentation division for application guidance and 700Pxx pressure module integration — contact Seven Star LLC today to place an order or request a tailored quotation.

Also available: Fluke 5502A Multi-Product Calibrator

Datasheets & Documents
  • PDF Datasheet Fluke 5522A Multi-Product Calibrator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 5522A Multi-Product Calibrator

Answers from our engineering team on installation, compatibility and integration.

01What makes the Fluke 5522A different from the 5502A?
The 5522A supports Fluke 700Pxx pressure modules and offers optional oscilloscope calibration to 1.1 GHz (the 5502A options reach 600 MHz) and a power quality option with harmonic and flicker simulation, extending beyond the electrical and temperature functions the 5502A covers.
02Can the Fluke 5522A calibrate pressure transmitters?
Yes, indirectly. The 5522A interfaces directly with Fluke 700Pxx series pressure modules, letting a technician add pressure calibration to the same instrument and traceability record used for electrical and temperature calibration.
03What oscilloscope bandwidth can the Fluke 5522A calibrate?
With the optional oscilloscope calibration module, the 5522A supports 600 MHz or 1.1 GHz bandwidth, with edge rise times under 300 picoseconds on the 1.1 GHz option, suitable for verifying high-bandwidth digital and mixed-signal oscilloscopes.
04How does the Fluke 5522A protect against miswiring during testing?
The 5522A includes reverse power protection along with immediate output disconnection or fuse protection on the output terminals, rated to ±300V peak, reducing the risk of damage to the reference circuitry during fast-paced multi-function calibration sequences.
05Is Seven Star LLC an experienced supply partner for Fluke products?
Yes. Seven Star LLC is an experienced supplier of Fluke in Oman and the GCC, supplying instruments including the 5522A along with technical support.