Fluke 6100A Electrical Power Standard
Description
Overview
Fluke 6100A is a precision electrical power standard purpose-built for calibrating energy meters, power quality analyzers, and revenue metering equipment rather than general-purpose multimeters. It generates pure sinusoidal voltage to 1000V and current to 20A at 100 ppm (0.01%) accuracy, and goes well beyond simple voltage/current sourcing by independently programming up to the first 100 harmonics, interharmonics, flicker per IEC 61000-3-3, and voltage dips and swells — the complex waveform library that utility metering labs and power quality test houses need to validate real-world grid disturbance measurement.
With engineering support in Muscat, Seven Star LLC supplies the Fluke 6100A to utility metering laboratories, power quality test facilities, and energy service providers across Oman and the GCC, with technical application guidance on Fluke’s GPIB-based calibration automation ecosystem.
Operating Principle
The Fluke 6100A synthesizes its output waveform digitally, allowing the fundamental sine wave and each of up to 100 individually addressable harmonic components to be defined, phased, and scaled independently — up to 30% of the fundamental value per harmonic — without the amplitude or phase distortion that limits simpler analog power sources. Phase angle across the multi-phase configuration is controlled to 3 milli-degrees annual accuracy with 200 micro-degree short-term stability, which is the level of precision required to validate the phase-sensitive power and energy calculations performed inside a revenue-grade energy meter.
Because the 6100A can also generate flicker, interharmonics, and voltage dips/swells simultaneously with the fundamental waveform, a test engineer can reproduce the compound disturbance conditions a meter or power quality analyzer will actually see on a live distribution network, rather than testing each disturbance type in isolation. This closed traceability chain, running from the fundamental waveform through every harmonic and disturbance component, is what allows the 6100A to serve as a primary reference standard for accredited energy and power quality calibration laboratories.
Engineering Design of the Fluke 6100A
The Fluke 6100A is built around a modular, rack-mountable master unit with a full-color graphical display for waveform and harmonic configuration, dedicated function keys, and a rotary control knob for fine parameter adjustment. Binding-post output terminals are arranged for direct connection to a meter under test, with separate voltage and current channels sized for continuous operation at the unit’s full 1000V/20A output ratings.
The 6100A’s single-phase master unit extends to two, three, or four-phase configurations through the addition of optional 6101A auxiliary phase modules, letting a metering lab scale a single reference platform from single-phase residential meter testing up to three-phase industrial revenue metering without changing calibration procedures. GPIB connectivity and onboard storage of test setups allow the instrument to be integrated into automated meter test benches that run standardized IEC and ANSI accuracy-class verification sequences with minimal manual intervention.
Key Features
The Fluke 6100A combines high-accuracy power sourcing with a full suite of power-quality disturbance simulation. Its principal capabilities include:
- Generates pure sinusoidal voltage to 1000V and current to 20A at 100 ppm (0.01%) accuracy for revenue meter and power analyzer calibration.
- Programs up to the first 100 harmonics independently, each adjustable to 30% of the fundamental, for realistic distorted-waveform testing.
- Produces flicker per IEC 61000-3-3, interharmonics, fluctuating harmonics, and voltage dips/swells, individually or in combination.
- Delivers phase angle accuracy of 3 milli-degrees annually with 200 micro-degree short-term stability across multi-phase configurations.
- Operates across a fundamental frequency range of 16 Hz to 450 Hz, extending to 6 kHz for harmonic content.
- Scales from single-phase to four-phase output through optional 6101A auxiliary modules for residential through industrial revenue metering.
- Communicates over GPIB for integration into automated meter test benches running IEC and ANSI accuracy-class verification sequences.
- Stores complete test setups for repeatable, auditable calibration procedures across a metering laboratory’s full test bench fleet.
Industrial Applications
Oman’s power utilities and independent power producers rely on precision power standards such as the Fluke 6100A to verify the revenue meters, power quality analyzers, and protection relays that directly determine billing accuracy and grid compliance reporting. Utility metering laboratories responsible for calibrating the meter population across residential, commercial, and industrial connections use the 6100A’s harmonics and disturbance-simulation capability to validate meter performance under the distorted waveform conditions increasingly common with solar inverters and variable-frequency drives connected to the grid. Independent power projects and industrial cogeneration facilities in the Sohar and Salalah free zones, where accurate energy accounting underpins commercial power purchase agreements, depend on this class of primary reference standard to keep their metering infrastructure within accredited traceability.
Backed by manufacturer datasheet documentation, Seven Star LLC distributes the Fluke 6100A to utility metering laboratories and energy service companies throughout the Sultanate of Oman, Muscat, and the wider GCC, supporting solar power plant operators, district cooling providers, and industrial cogeneration facilities that all depend on precisely calibrated power and energy measurement. Seven Star LLC’s technical support helps metering laboratories in Sohar, Salalah, and Muscat specify and source a 6100A reference standard, with lead time confirmed at quotation.
Technical Specifications
The table below summarizes the primary specifications of the Fluke 6100A relevant to utility metering and power quality laboratory procurement.
| Parameter | Specification |
|---|---|
| Model | Fluke 6100A |
| Voltage Output | 6.4V to 1008V |
| Current Output | 0.05A to 20A |
| Voltage/Current Accuracy | 100 ppm (0.01%) |
| Phase Angle Accuracy | 3 milli-degrees (annual), 200 µ-degrees (short-term) |
| Harmonics | First 100, independently set to 30% of fundamental |
| Complex Signals | Flicker (IEC 61000-3-3), interharmonics, dips/swells |
| Frequency Range | 16 Hz–450 Hz fundamental, to 6 kHz harmonics |
| Phase Configuration | 1 to 4 phase (with 6101A auxiliary modules) |
| Interfaces | GPIB, onboard setup storage |
Request a Quote for Fluke 6100A Electrical Power Standard
Seven Star LLC invites utility metering laboratories, power quality test facilities, and energy service providers across Oman and the GCC to submit a formal RFQ for the Fluke 6100A Electrical Power Standard. Working closely with plant engineers in the region, Seven Star LLC supplies on request with lead time confirmed at quotation, provides the full technical datasheet on request, and connects buyers directly with its instrumentation division for application guidance and GPIB automation support — contact Seven Star LLC today to place an order or request a tailored quotation.
Browse the full Fluke range or see more Portable Test & Measurement products supplied by Seven Star LLC in Oman and the GCC.
Datasheets & Documents
- Instruction Manual Fluke 6100A Electrical Power Standard Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 6100A Electrical Power Standard
Answers from our engineering team on installation, compatibility and integration.
01What is the Fluke 6100A used for?
The Fluke 6100A is a precision electrical power standard used to calibrate energy meters, power quality analyzers, and revenue metering equipment by generating accurate voltage, current, harmonics, and power quality disturbance signals.
02Can the Fluke 6100A simulate real-world grid disturbances?
Yes. The 6100A can generate flicker per IEC 61000-3-3, interharmonics, fluctuating harmonics, and voltage dips and swells, individually or simultaneously with the fundamental waveform, reproducing the compound disturbance conditions a meter sees on a live network.
03Does the Fluke 6100A support three-phase meter calibration?
Yes. The 6100A master unit scales from single-phase to two, three, or four-phase configurations through optional 6101A auxiliary phase modules, covering residential through industrial revenue metering from a single reference platform.
04How accurate is the Fluke 6100A for phase angle measurement?
The 6100A delivers phase angle accuracy of 3 milli-degrees on an annual basis with 200 micro-degree short-term stability, precision suitable for validating the phase-sensitive calculations performed inside revenue-grade energy meters.
05Is Seven Star LLC an experienced supply partner for Fluke products?
Yes. Seven Star LLC is an experienced supplier of Fluke in Oman and the GCC, supplying instruments including the 6100A along with technical support.