Brand:

Fluke 9142 Field Metrology Well, -25 to 150 C

Description

9142 low-temperature field metrology well from -25 °C to 150 °C

The Fluke 9142 Field Metrology Well is a portable dry-block temperature calibrator for the low end of the industrial range, from -25 °C to 150 °C. A dry-block heats or cools a metal block with wells into which temperature sensors are inserted, so that thermocouples, RTDs and thermometers can be checked against a known temperature without a liquid bath. The 9142 is the lowest of three models, with the 9143 covering 33 °C to 350 °C and the 9144 covering 50 °C to 660 °C. Seven Star LLC supplies the 9142 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

Ordering uses the pattern 9142-X, or 9142-X-P for the process version. The X is replaced with a letter for the insert, as decoded below.

Element Meaning Detail
9142 Model Low-temperature field metrology well, -25 °C to 150 °C
-X Insert code A to F A misc. imperial holes, B comparison imperial holes, C 0.25 inch holes, D metric comparison holes, E metric misc. holes, F metric comparison holes with 0.25 inch hole
-P Process option Built-in two-channel readout for reference thermometer, RTD, thermocouple and 4 to 20 mA with 24 V loop power

9142 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 9142 (9142-X, 9142-X-P)
Temperature range at 23 °C ambient -25 °C to 150 °C
Display accuracy ±0.2 °C full range
Process version accuracy (built-in reference readout) ±0.01 °C at -25 °C; ±0.02 °C at 155 °C
Stability ±0.01 °C full range
Radial uniformity ±0.01 °C full range
Axial uniformity at 40 mm ±0.05 °C full range
Immersion depth 150 mm (6 in)
Heating time (max) 23 minutes
Cooling time 15 minutes to -25 °C
Size (H x W x D) 290 x 185 x 295 mm
Weight 8.2 kg (18 lb)
Process RTD inputs 2-, 3- or 4-wire: Ni-120, Pt-100 (385), Pt-100 (3926), Pt-100 (JIS), resistance 0 to 400 Ω
Process thermocouple inputs J, K, T, E, R, S, B, L, U, N, C and mV
Process mA 0 to 24 mA with 24 V to 28 V dc loop power, 0.02 % of reading + 0.002 mA
Operating conditions 0 °C to 50 °C; specifications guaranteed at 13 °C to 33 °C ambient

How the 9142 is used for transmitter loop calibration

Temperature transmitters are usually calibrated on the electronics side while the sensor is left unchecked, yet the sensor is often the larger source of error. With the process version of the 9142, the transmitter sensor goes into the well beside a reference PRT, the transmitter output is wired to the front panel, and the 24 V loop supply powers the loop while mA is measured. The calibrator then shows block temperature, reference temperature and loop current together, giving as-found and as-left data for the complete loop in one setup.

The process version stores up to 20 tests with an alphanumeric ID, block temperature, reference value, error, date and time, and the 9930 Interface-it software is supplied to pull data into a report. Thermostatic switches can be tested with an automated routine that cycles the switch three times and reports the deadband.

9142, 9143 and 9144 compared

All three share the same footprint of 290 x 185 x 295 mm and the 150 mm immersion depth. They differ in range, speed and accuracy. The 9142 is the only one that cools below ambient.

Model Range Display accuracy Stability Weight
9142 -25 to 150 °C ±0.2 °C ±0.01 °C 8.2 kg
9143 33 to 350 °C ±0.2 °C ±0.02 to 0.03 °C 7.3 kg
9144 50 to 660 °C ±0.35 to 0.5 °C ±0.03 to 0.05 °C 7.7 kg

Selecting the 9142

  • Check that the temperatures you calibrate are between -25 °C and 150 °C; use the 9143 or 9144 above that.
  • Choose the insert code A to F that matches your sensor diameters, metric or imperial.
  • Decide on the process option if you need a built-in readout and loop power.
  • Order a reference PRT if you want to use the built-in reference thermometry.
  • Confirm mains supply and plug type for delivery to your site.

Commissioning and maintenance of the 9142

Place the unit on a stable surface away from drafts, with airflow clear around the case. Allow time to reach the setpoint and wait for the stability indicator before taking readings. Keep wells clean and dry; moisture in a cold well can freeze and trap probes. Each unit is supplied with a calibration certificate from an accredited laboratory according to the datasheet, a well insert, a user’s manual and a spare probe connector, and a power cord. Recalibrate periodically.

Typical applications of the 9142 in Oman and the GCC

The 9142 suits cold-chain and process checks: refrigeration monitors, HVAC chilled-water sensors, laboratory thermometers, and RTDs used in process lines up to 150 °C. Its quick cooling helps when a team has a long list of sensors to visit. In Oman and the GCC, high ambient temperatures make the ambient limits of 13 °C to 33 °C for guaranteed specifications significant; calibrate in an air-conditioned workshop or cabin when you can.

Information to send with an RFQ for the 9142

  • Part number 9142, process option (-P) or not, and insert code (A to F)
  • Quantity and reference PRT or accessories needed
  • Sensor types and diameters to be calibrated
  • Delivery location and time frame
  • Calibration certificate requirement

Storage, handling and spares for the Fluke 9142

Keep the Fluke 9142 in its carrying case when it is not in use, and store it in a clean, dry place. Remove or charge the batteries as recommended in the user manual before long storage. Field teams in Oman and the GCC should avoid leaving the instrument in a vehicle in the sun, as high cabin temperatures can exceed the storage range and shorten battery life.

  • Check the instrument, cables, hoses or lenses for damage before each job.
  • Clean the unit with a soft, slightly damp cloth only; do not use solvents unless the manual allows them.
  • Plan a calibration interval that matches your quality system, and keep the calibration certificate with the asset record.
  • Order wear parts and accessories, such as batteries, test leads, hoses or adapters, together with the instrument.

For calibration and test work, it helps to state in your RFQ whether you need an accredited calibration certificate with the Fluke 9142, so the right documents can be confirmed with the quotation.

Documents and quotation

A datasheet covering the 9142, 9143 and 9144 is attached on this page.

Send us the part number 9142 with the insert code and process option, and we will confirm availability and a quotation.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 9142 Field Metrology Well, -25 to 150 C

Answers from our engineering team on installation, compatibility and integration.

01What temperature range does the Fluke 9142 cover?
The 9142 covers -25 °C to 150 °C at 23 °C ambient, with a display accuracy of 0.2 °C over the full range and stability of 0.01 °C.
02What does the P option mean on the Fluke 9142?
The -P process version adds a two-channel readout for reference PRT, RTD, thermocouple and 4 to 20 mA, with 24 V loop power and storage of up to 20 tests.
03How fast does the Fluke 9142 cool?
The datasheet states a cooling time of 15 minutes to -25 °C and a heating time of up to 23 minutes, with a weight of 8.2 kg for field portability.
04What do the letters A to F mean in 9142-X?
The letter selects the well insert: imperial or metric holes, comparison or miscellaneous patterns, with a 0.25 inch hole in some versions. Choose according to your sensor diameters.
05Is a certificate included with the Fluke 9142?
The datasheet lists a NIST-traceable certificate of calibration, an accredited calibration certificate for each unit, a user manual, a well insert and, for process units, test leads and software.