Brand:

Fluke 700G27 Precision Pressure Test Gauge, 300 psi

Description

700G27 precision pressure test gauge for 300 psi transmitter and gauge checks

The Fluke 700G27 is a digital precision pressure test gauge covering -12 to 300 psi (-0.83 to 20 bar) with 0.01 psi resolution and an accuracy of 0.05 % of full scale. It is a gauge, not a calibrator: it shows pressure on a 5.5 digit display with a bar graph and acts as the reference when a hand pump applies pressure to a transmitter, switch or mechanical gauge. Seven Star LLC supplies the 700G27 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The code decodes as follows: 700G is the series, and 27 is the range code of the 300 psi gauge in the datasheet ordering list (“Fluke-700G27 Pressure Gauge, 300 PSIG”).

700G27 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 700G27
Range -12 psi to 300 psi (-0.83 bar to 20 bar)
Resolution 0.01 psi, 0.001 bar
Accuracy ±0.05 % of full scale (positive pressure)
Burst pressure 1200 psi (80 bar)
Media Liquids or gases compatible with 316 stainless steel
Display 5.5 digits, 16.53 mm high, with a 20-segment bar graph
Connection 1/4 in NPT male; 1/4 in NPT to 1/4 in ISO adapter included
Housing / weight Cast zinc-aluminium / 0.56 kg with holster
Dimensions 12.7 x 11.4 x 3.7 cm
Power / battery life Three AA alkaline / 1,500 hours without backlight, 2,000 hours at slow sample rate
Temperature compensation 0 °C to 50 °C to rated accuracy; add 0.005 % FS per °C from -10 °C to 0 °C and 50 °C to 55 °C
Logging Up to 8,493 readings with 700G/TRACK software and cable (sold separately)
Hazardous area rating CSA Class 1, Div 2, Groups A-D; ATEX II 3 G Ex ic IIB T6 Gc
Warranty / supplied with Three years / traceable calibration certificate and 1/4 in NPT to ISO adapter

Where 300 psi fits in the 700G series

The series runs from 10 inH2O to 10,000 psi, with absolute gauges at 15, 30, 100 and 300 psia and reference-class gauges at six pressure ranges. The 700G27 sits where compressed air and instrument air headers, hydraulic control circuits and many pumps operate, so one gauge can serve a broad workload. It sits below the 1,000 psi limit that separates the pneumatic and hydraulic pump kits, so either kit can be used depending on the medium and the pressure needed.

Model Range Resolution Burst pressure
700G06 -12 to 100 psi 0.01 psi 400 psi
700G27 -12 to 300 psi 0.01 psi 1200 psi
700G07 -12 to 500 psi 0.01 psi 2000 psi
700G08 -14 to 1000 psi 0.1 psi 4000 psi

Using the 700G27 with pump kits

With the Fluke-700PTPK pneumatic kit, the gauge connects directly to the 700PTP-1 hand pump, which generates up to 600 psi (40 bar) or a vacuum, and the case keeps the pump and gauge together. For hydraulic work, the 700HTPK kit with the 700HTP-2 pump reaches 10,000 psi, but the datasheet recommends hydraulic kits with gauges of 1,000 psi or more, so for a 300 psi gauge the pneumatic kit or a separate pump and hose is the usual choice. Transmitter test hoses rated to 5,000 or 10,000 psi are listed as accessories.

Reading the gauge correctly matters as much as choosing it. The bar graph shows the applied pressure as a percentage of range from 0 to 100 %, which helps to spot a slowly leaking connection, because the bar creeps down while the pump is idle. Hold the pressure steady for a few seconds before recording, allow for small temperature changes in a closed system after pumping, and record the reading together with the device output so that as-found and as-left errors can be calculated at each test point.

Selecting the 700G27

  • Choose a gauge whose full scale is not far above the test pressure, so the resolution and accuracy are well used.
  • Check that burst pressure of 1200 psi is not exceeded by the source or by thermal expansion in a closed system.
  • Verify the media compatibility with 316 stainless steel.
  • Plan a pump kit and hose set that matches the threads on your devices.
  • Order the 700G/TRACK software if you want to log pressure over time.

Use and maintenance of the 700G27

Zero the gauge before each use with the port open to atmosphere, and use thread tape or a bonded seal appropriate to the fitting. Bleed pressure slowly before disconnecting. Keep the gauge in its holster, protect the display from sunlight and store it dry. Replace the three AA cells when the low-battery icon appears. Follow your quality system for the recalibration interval; a traceable certificate is included with the gauge as supplied.

Typical applications of the 700G27 in Oman and the GCC

Instrument workshops and field crews in oil and gas, power, water and desalination plants use a 300 psi gauge to check pressure transmitters on air and water lines, to calibrate dial gauges and to test relief and pressure switch settings. The Class 1 Div 2 and ATEX II 3 G Ex ic IIB T6 Gc ratings listed in the datasheet are useful in classified areas, subject to the site permit and the markings on the unit.

Information to send with an RFQ for the 700G27

  • Part number 700G27
  • Quantity and any pump kit, hose kit or software
  • Pressure range, media and thread type
  • Delivery location and time frame
  • Calibration certificate requirement

Storage, handling and spares for the Fluke 700G27

Keep the Fluke 700G27 in its carrying case when it is not in use, and store it in a clean, dry place. Remove or charge the batteries as recommended in the user manual before long storage. Field teams in Oman and the GCC should avoid leaving the instrument in a vehicle in the sun, as high cabin temperatures can exceed the storage range and shorten battery life.

  • Check the instrument, cables, hoses or lenses for damage before each job.
  • Clean the unit with a soft, slightly damp cloth only; do not use solvents unless the manual allows them.
  • Plan a calibration interval that matches your quality system, and keep the calibration certificate with the asset record.
  • Order wear parts and accessories, such as batteries, test leads, hoses or adapters, together with the instrument.

For calibration and test work, it helps to state in your RFQ whether you need an accredited calibration certificate with the Fluke 700G27, so the right documents can be confirmed with the quotation.

Documents and quotation

A datasheet covering the 700G series is attached on this page.

Send us the part number 700G27 and the quantity and we will confirm availability and a quotation.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 700G27 Precision Pressure Test Gauge, 300 psi

Answers from our engineering team on installation, compatibility and integration.

01What range does the Fluke 700G27 cover?
The 700G27 covers -12 psi to 300 psi, or -0.83 bar to 20 bar, with 0.01 psi resolution and a burst pressure of 1200 psi (80 bar).
02What is the accuracy of the Fluke 700G27?
The datasheet gives an accuracy of 0.05 % of full scale for the gauge, with temperature compensation between 0 °C and 50 °C and extra error outside that band.
03Which pump kit suits the Fluke 700G27?
The 700PTPK pneumatic kit generates up to 600 psi and works with gauges of 1,000 psi or less. The hydraulic kit is intended for gauges of 1,000 psi or more.
04Is the Fluke 700G27 usable in hazardous areas?
The datasheet lists CSA Class 1, Div 2, Groups A-D and ATEX II 3 G Ex ic IIB T6 Gc ratings. Always confirm the markings and your site permit before use.
05Can the Fluke 700G27 log data?
Yes, with the optional 700G/TRACK software and cable it can record up to 8,493 readings and be configured for remote logging events.