Endress+Hauser PMD75 Deltabar S Differential Pressure Transmitter

Description

Endress+Hauser PMD75 Deltabar S differential pressure transmitter for flow, level and filter monitoring

The Endress+Hauser PMD75 is a Deltabar S differential pressure transmitter for flow measurement together with primary devices, for level, volume and mass measurement in liquids, and for differential pressure monitoring such as filters and pumps. It is the high-performance device of the Deltabar family, and is documented in Technical Information TI00382 together with the FMD77 and FMD78.

The Endress+Hauser PMD75 reaches a reference accuracy of up to 0.035 percent, a turn down of up to 100 to 1, and certification for flow and differential pressure monitoring up to SIL 3 under IEC 61508 by TUEV SUED. With a diaphragm seal mount, process temperatures up to 400 degrees C become possible, and the patented TempC process membrane of the diaphragm seal keeps temperature-related error to a minimum.

Key features of the PMD75

  • Reference accuracy up to 0.035 percent with very good reproducibility and long-term stability
  • Turn down up to 100 to 1, higher on request
  • Used for flow and differential pressure monitoring up to SIL 3, certified to IEC 61508 by TUEV SUED
  • Function monitoring from measuring cell to electronics for safe operation
  • HistoRom/M-DAT memory makes electronics replacement quick
  • HART, PROFIBUS PA and FOUNDATION Fieldbus communication options on the PMD75

PMD75 technical specifications

Parameter Value
Product family Deltabar S, type PMD75 (TI00382 covers PMD75, FMD77, FMD78)
Measured variables Differential pressure, flow with primary elements, level, volume and mass in liquids
Reference accuracy Up to 0.035 percent
Turn down Up to 100 to 1, higher on request
Communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Process temperature Up to 400 degrees C possible with diaphragm seal mount
Ambient temperature with display Minus 20 to plus 70 degrees C
Functional safety SIL 3 for flow and differential pressure monitoring (IEC 61508, TUEV SUED)
Diaphragm seal option TempC process membrane reduces temperature effects

The values are taken from the manufacturer Technical Information for the PMD75. Measuring cell ranges, static pressure limits and process connections depend on the ordering code.

Typical applications in Oman and the GCC

In oil and gas, the PMD75 is typically used with orifice plates, Venturi tubes and averaging pitot tubes for gas and liquid flow, with separators for level and with filters, strainers and coalescers for differential pressure monitoring. The SIL 3 certification supports use in safety functions, and the diaphragm seal option handles hot or viscous media.

In power, desalination and water plants, the device measures flow across orifice plates, filter and strainer pressure drop, and level in pressurised tanks. In manufacturing and chemical plants it is used on reactor level, heat exchanger monitoring and steam flow, where accuracy and long-term stability are important.

Selection and compatibility notes for the PMD75

Select the PMD75 when the highest accuracy and safety integrity are needed, or when diaphragm seals are required for high temperature or aggressive media. The Deltabar M PMD55 is a compact alternative for less demanding duties, and the PMD78B is the newer generation with Bluetooth and Heartbeat Technology. Check the measuring cell range, the maximum static pressure, the sealing materials and the output type before requesting a quote for the device.

Installation and commissioning of the PMD75

Mount the PMD75 so that the process connection sits as close to the measuring point as practical and, for liquids, so that no gas pocket can collect in front of the diaphragm. For gases, mount above the tapping point so condensate drains back into the line. Any change of mounting orientation shifts the zero point slightly, so correct the position offset once the device is in its final position and the line is at atmospheric or reference pressure. Use a shut-off valve or a valve manifold so that the device can be isolated and checked without stopping the process, and use a shielded two-core cable with the shield grounded at one end only. Commissioning of the device is a matter of checking the supply voltage at the terminals, setting the lower and upper range values, choosing the damping, and confirming the output at a known pressure.

Maintenance

The PMD75 has no wearing parts, so routine maintenance is limited to periodic inspection. Check the process connection and seal for leakage, look for blocked impulse lines or crystallised product, and verify the zero point at atmospheric pressure when the process allows it. Where a safety function is involved, follow the proof-test interval stated in the safety manual of the device. Replace seals whenever the connection is opened, and keep the diaphragm free of buildup by flushing rather than by scraping, because a scratched diaphragm changes the measurement. Record the as-found and as-left values at every check so that drift of the device can be trended over the years.

Related products and ordering notes

Related devices include the Deltabar M PMD55, the newer Deltabar PMD78B and the Cerabar S PMC71 for pressure. Valve manifolds, mounting brackets and diaphragm seals can be added to the RFQ for the PMD75.

In short: the device is a high-accuracy differential pressure transmitter with up to 0.035 percent accuracy, 100 to 1 turn down and SIL 3 certification. Send an RFQ for availability. When you prepare the enquiry, state the pressure type (gauge or absolute), the lower and upper range values, the wetted material you need, the thread or flange size, the cable entry and any hazardous area marking. A complete enquiry lets us answer quickly and avoids a second round of questions, and it also helps to say whether the device will be used in a safety loop, because that changes the documentation you should request.

Before shipment, a pressure transmitter should be checked for the right range, the right wetted materials, an undamaged diaphragm protection cap and a legible nameplate. We recommend that receiving staff compare the nameplate data with the purchase order, keep the protective cap on until the moment of installation, and store the unit in a dry place. If the application involves oxygen, hydrogen or ultrapure gas, state this in the enquiry so that the correct cleaning and documentation are requested.

Documents and quotation

The official Endress+Hauser Deltabar S PMD75, FMD77, FMD78 Technical Information (TI00382P) is attached to this page as a PDF. The front page lists a reference accuracy of up to 0.035 % and turn down up to 100:1, the Mechanical construction chapter from page 44 shows the process connections and dimensions, and the Ordering information chapter starts on page 102. Quote the PMD75 order code from your nameplate in your request so we can check the configuration before we send a written quotation.

Other Models in the Eh Deltabar Range

Seven Star LLC supplies models from the Eh Deltabar range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser PMD75 Deltabar S Differential Pressure TransmitterPressure TransmittersYou are viewing this model
Endress+Hauser PMD55 Deltabar M Differential Pressure TransmitterPressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet Endress+Hauser Deltabar S PMD75 Technical Information TI00382P (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser PMD75 Deltabar S Differential

Answers from our engineering team on installation, compatibility and integration.

01What can the PMD75 measure?
The datasheet lists flow measurement with primary devices, level, volume and mass in liquids, and differential pressure monitoring of filters and pumps.
02How accurate is the PMD75?
The reference accuracy is up to 0.035 percent, as stated in the Technical Information TI00382.
03Is the PMD75 suitable for safety functions?
It is used for flow and differential pressure monitoring up to SIL 3, certified to IEC 61508 by TUEV SUED.
04Can the PMD75 work with high process temperatures?
Yes. With a diaphragm seal mount, process temperatures up to 400 degrees C are possible according to the datasheet.
05How do I request a quotation for the PMD75?
Send an RFQ to Seven Star LLC with the part number PMD75, quantity, cell range, static pressure, connection and output signal, and we reply with availability and an offer.