- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser PMP71B Cerabar Pressure Transmitter up to 700 bar
Description
Endress+Hauser PMP71B summary
The Endress+Hauser PMP71B is the top model of the metallic-membrane Cerabar B range. Its Technical Information TI01509P lists measuring ranges up to 700 bar (10500 psi), process temperatures up to 400 degrees Celsius with a diaphragm seal, and accuracy up to 0.025 percent. It communicates over 4-20 mA with HART, PROFINET with Ethernet-APL or PROFIBUS PA, and it can run the Heartbeat Technology verification package on request.
If you only need 400 bar and 0.055 percent accuracy, the PMP51B costs less in complexity; the PMP71B is selected when the application needs the lowest uncertainty, the highest range or a PROFIBUS PA connection.
PMP71B functions
- Large backlit display with menus guided by wizards, plus Bluetooth operation.
- Heartbeat verification and monitoring detects pressure shocks or supply voltage changes.
- Metallic membrane 316L (1.4435), 316L TempC or Alloy C276.
- Platinum accuracy of 0.025 percent for the 400 mbar and 1 bar cells.
- Stainless dual-compartment housing weighing 3.3 kg, or aluminium at 1.4 kg and single compartment at 1.1 kg.
- Alarm and diagnostics per NAMUR NE 43 on current output versions.
PMP71B technical overview
| Parameter | Value |
|---|---|
| Maximum range | up to 700 bar (10500 psi) |
| Process temperature | up to 400 degrees Celsius with diaphragm seal |
| Reference accuracy 400 mbar cell | 0.05 percent standard, 0.025 percent Platinum at turn down 1 to 1 |
| Reference accuracy 1 bar cell | 0.05 percent standard to turn down 2.5 to 1, 0.025 percent Platinum at 1 to 1 |
| Long-term stability, 400 mbar to 2 bar cells | 0.08 percent 1 year, 0.12 percent 5 years, 0.13 percent 10 years, 0.14 percent 15 years |
| Long-term stability, other cells | 0.05 percent in 1 year, 0.07 percent in 5 years |
| HART supply | 10.5 to 35 V DC, Ex i 10.5 to 30 V DC |
| PROFIBUS PA supply | 9 to 32 V DC; FISCO 9 to 17.5 V DC; entity 9 to 24 V DC; 14 mA |
| APL | power class A, 9.6 to 15 V DC, 540 mW |
| Response time | HART 330 ms minimum acyclic; PROFIBUS PA about 10 to 13 ms cyclic; APL 32 ms |
| Housing weights | 1.1 kg, 1.4 kg aluminium, 3.3 kg stainless steel |
| Ingress protection | IP66/68, Type 4X/6P |
Why PMP71B and not another Cerabar
Against the PMP51B, the PMP71B doubles the quality of the specification: accuracy of 0.025 percent against 0.055 percent, one-year drift of 0.05 percent against 0.10 percent on higher cells, and a ceiling of 700 bar against 400 bar. Against the ceramic PMC71B, the PMP71B swaps the ceramic membrane for metal so that the 40 bar limit disappears.
The Platinum accuracy applies for turn downs up to 5 to 1, and standard accuracy holds up to 100 to 1, so a single transmitter can be re-ranged over a wide span without losing the quoted figures.
PMP71B in demanding duty in Oman and the GCC
The PMP71B suits high-accuracy pressure points such as compressor discharge and suction, wellhead and gas injection lines, hydraulic presses in industry, and boiler feed lines. Where a diaphragm seal is chosen, hot or viscous media such as heavy crude residues or polymers can be measured without plugging impulse lines. PROFIBUS PA is the option to choose when the plant already runs PA segments through a segment coupler.
For level duty, the PMP71B can be configured for volume or mass in vessels of any shape through a freely programmable characteristic, and with a diaphragm seal on a flange it measures level in closed pressurised vessels. The cell choice then decides the span: a 400 mbar or 1 bar cell resolves small hydrostatic heads, while the 10 bar and higher cells follow process pressure. In every case the one-year drift figure scales with the upper range limit, so a smaller cell gives smaller absolute drift.
Mounting and commissioning of PMP71B
Install the PMP71B with a valve manifold for isolation and zeroing. For steam apply a siphon so the membrane sees condensate. Keep ambient temperature between minus 40 and plus 85 degrees Celsius. With diaphragm seals, mount the transmitter below the upper seal or follow the datasheet capillary rules, because the fill fluid column creates a position shift that must be zeroed. The wizard and Bluetooth link guide range setting.
Order code points to check for PMP71B
Because the PMP71B is configurable, the base name is only the start of an order. The Technical Information lists the choices that must be confirmed before a quotation: the cell range and whether it is absolute or gauge, the accuracy class (standard or Platinum), the membrane material, the process connection or diaphragm seal, the communication (HART, Ethernet-APL or PROFIBUS PA), the housing material and cable entry, and the display and Bluetooth option.
Hazardous-area certificates, marine classifications and functional safety documentation are added in the same code. If you are replacing an existing instrument, send the old nameplate text; it lets us match range, connection and approvals quickly. Remember that the standard accuracy is valid up to a turn down of 100 to 1, while the Platinum figures apply up to 5 to 1, so specify the span you really need.
Care for PMP71B
Plan the spare strategy as well: because the electronics, display and sensor of this transmitter family are described in the same documentation, a stock unit with the same order code can replace a failed one and be re-ranged with the wizard in minutes. Verification can be performed on demand through Heartbeat without removing the device, which reduces plant downtime. Otherwise, visually check the connection, keep the cover O-ring seated, and confirm the zero with the process isolated every year.
Documents and quotation
The Technical Information TI01509P for PMP71B is attached as the datasheet. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. For an RFQ please send PMP71B with quantity, range and approvals.
Datasheets & Documents
- Datasheet Endress+Hauser PMP71B Cerabar Pressure Transmitter up to 700 bar Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser PMP71B Cerabar Pressure Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum range of the PMP71B?
The front page of the datasheet gives pressure measuring ranges up to 700 bar (10500 psi), the highest of the Cerabar B transmitters.
02How accurate is the PMP71B?
Accuracy up to plus or minus 0.025 percent is stated. In the Platinum version the 400 mbar cell holds 0.025 percent at turn down 1 to 1, while standard cells list 0.05 percent.
03Which communication versions exist for the PMP71B?
The datasheet covers 4 to 20 mA with HART, PROFINET over Ethernet-APL and PROFIBUS PA, with Bluetooth on the display versions.
04What is the supply voltage on PROFIBUS PA for the PMP71B?
In non-hazardous, Ex d and Ex e areas it is 9 to 32 V DC, under the FISCO principle 9 to 17.5 V DC and under the entity concept 9 to 24 V DC, with 14 mA nominal current.
05How do I get a price for a PMP71B?
Prices are not listed. Send an RFQ with PMP71B, the range, process connection or diaphragm seal, protocol, approvals and quantity and we will respond.


















Reviews