Endress+Hauser 50E Promag 50E Economy PTFE Flowmeter

Description

50E: where economy meets fieldbus capability

TI01161D presents the Endress+Hauser 50E as the economical flowmeter with a modular electronic concept, fully suitable for basic applications in the chemical and process industry. It carries a PTFE liner, offers sizes up to DN 600, and, unlike the plainer Promag 10E, lists Ex approvals for Zone 2 and communication through HART or PROFIBUS DP/PA.

Application-specific Quick Setups speed up commissioning, and the display is two-line, backlit, with push buttons. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and we quote the 50E by the root printed on the nameplate.

50E key points

  • PTFE liner with 316L, Alloy C22 or tantalum electrodes
  • Sizes to DN 600 in compact or remote versions
  • Zone 2 approvals noted on the cover page
  • HART or PROFIBUS DP/PA, modular transmitter
  • Medium temperature from minus 10 to plus 110 degC

50E parameters

Parameter Value for 50E
Product root 50E, Proline Promag 50E (TI01161D, edition 02.17)
Positioning Economical flowmeter with modular electronic concept
Liner PTFE
Nominal diameters Maximum DN 600 (24 inch)
Medium temperature -10 to +110 degC (+14 to +230 degF)
Ex approvals Zone 2 listed on the cover page
Measuring tube Stainless steel 1.4301 (304) or 1.4306 (304L)
Electrodes 1.4435 (316, 316L), Alloy C22 or tantalum
Sensor housing Die-cast aluminum DN 25 to 300; protective lacquering DN 350 to 600
Minimum conductivity 5 microsiemens per cm; 20 for demineralized water
Pulse output accuracy 0.5 % of reading plus 1 mm/s; optional 0.2 % plus 2 mm/s
Supply 16 to 62 V DC; 20 to 55 V AC; 85 to 260 V AC
Communication HART, PROFIBUS DP/PA
Display Two-line backlit with push buttons
Ambient temperature, transmitter -20 to +60 degC; optional -40 to +60 degC
Protection class IP67 (NEMA 4X)
Vibration Acceleration up to 2 g per IEC 60068-2-6

Typical 50E duties in Gulf industry

Chemical dosing headers, demineralized-water systems, brine lines, wash water and general process water in petrochemical, power and manufacturing plants are within scope. The 5 microsiemens minimum makes it usable on weakly conductive process water, and the 20 microsiemens figure for demineralized water gives a clear selection rule for boiler make-up lines. Hazardous-area approvals for Zone 2 allow installation near flammable-gas sources where the classification permits.

How 50E differs from other Promag 50 variants

The 50E is the cheaper PTFE sensor. The 50P also uses PTFE, but adds PFA, platinum and titanium electrodes, temperatures up to 180 degC and a stronger pressure statement, whereas the 50E stops at 110 degC and offers fewer electrode materials. Compared with the 50W it targets chemical rather than water duty, and compared with the Promag 10E it adds fieldbus and Zone 2 approvals along with the modular transmitter. The 50E is not a hygienic meter like the 50H.

Specifying 50E

Match diameter, flange standard and rating, electrode grade, communication, supply and housing layout with the nameplate. Because the flanges are carbon steel with protective lacquering, confirm that the plant environment is compatible, and ask for stainless alternatives only where the datasheet lists them. Add the details to the RFQ for Seven Star LLC.

Mounting and commissioning 50E

Keep the pipe full, maintain straight-run advice and ground the sensor correctly. Use the Quick Setup menus for the application, set the current output range, and verify the totalizer. If the transmitter is to be used in a cold region, the optional minus 40 degC version is available.

Servicing 50E

Check seals and bolts after thermal cycling, keep electrodes clean in coating media and refresh any lacquer damage on the flanges. Record the PTFE temperature history because the upper limit is 110 degC.

Because PTFE is sensitive to excursions beyond its temperature and pressure limits, any steam-out of the line should be avoided unless the diagrams in the datasheet allow it.

On the electrical side the 50E follows the Proline 50 concept. The current output is galvanically isolated, can be active or passive and has a selectable time constant, and the pulse output can drive remote totalizers. A status input of 3 to 30 V DC can reset totalizers, suppress measured values or clear error messages. For plants with a fieldbus, PROFIBUS DP or PA removes the need for separate analog wiring. The two-line display shows flow and totalizer values and the Quick Setup menus guide the user through the application, which shortens start-up on a dosing header or a demineralized-water line.

For quotations, send the nameplate root, diameter, flange standard, electrode material, communication and supply voltage. If the old meter was in a hazardous area, quote the approval marking as well so that the correct safety documentation can be matched. The sensor is a PTFE-lined carbon-steel-flanged design, and spare gaskets and ground disks are best ordered together with the meter, because the installer will need them at the first replacement of the line. Where a plant already holds a Promag 10E spare, remember that the 50E carries a different transmitter concept, so the two roots are not interchangeable without a review of outputs and communication.

Quick answers on 50E

The 50E supply options are 16 to 62 V DC, 20 to 55 V AC and 85 to 260 V AC. Vibration resistance is up to 2 g following IEC 60068-2-6. Accuracy of the pulse output is 0.5 percent of reading plus 1 mm per second as standard, with an optional 0.2 percent of reading plus 2 mm per second.

Documents and quotation

Technical Information TI01161D is the datasheet for the 50E. Send an RFQ to Seven Star LLC with part number 50E, nominal diameter, flange standard, communication and quantity.

Spares and Lifecycle Considerations

For critical service, many plants hold one Endress+Hauser 50E as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical ultrasonic flowmeters units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.

Other Models in the Promag 50 Range

Seven Star LLC supplies models from the Promag 50 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser 50W Promag 50W Water Electromagnetic FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 50L Promag 50L Lap-Joint Electromagnetic FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 50E Promag 50E Economy PTFE FlowmeterUltrasonic FlowmetersYou are viewing this model
Endress+Hauser 50D Promag 50D Compact Wafer FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 50H Promag 50H Hygienic Electromagnetic FlowmeterUltrasonic FlowmetersView details
Datasheets & Documents
  • PDF Datasheet Endress+Hauser 50E Promag 50E Economy PTFE Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 50E Promag 50E Economy PTFE Flowmeter

Answers from our engineering team on installation, compatibility and integration.

01What is the 50E?
The economical PTFE-lined member of the Promag 50 family with a modular electronic concept, intended for basic chemical and process applications.
02What is the largest size of the 50E?
DN 600 (24 inch) is the maximum nominal diameter listed on the cover page of TI01161D.
03What temperature limits apply to the 50E?
The PTFE liner is rated from minus 10 to plus 110 degC (14 to 230 degF).
04Does the 50E have hazardous-area approvals?
The cover page lists Ex approvals for Zone 2; the safety instructions hold the exact conditions.
05How do I quote the 50E?
Send an RFQ to Seven Star LLC with 50E, nominal diameter, flange standard, communication and quantity.