Endress+Hauser 10H Promag 10H Sanitary Electromagnetic Flowmeter

Description

10H: the small-bore sanitary electromagnetic meter from the Promag 10 family

Where a process feeds only a few litres per minute, a normal flowmeter is oversized. TI00095D positions the Endress+Hauser 10H as the flowmeter for the smallest flow rates, with a cost-effective transmitter, a PFA liner and a stainless steel sensor housing that the cover page ties to 3-A and EHEDG. Its wetted parts can be cleaned in place or sterilized in place, so the same 10H serves a dairy dosing line and a pharmaceutical buffer skid.

The sensor span starts at DN 2, whose recommended flow window is 0.06 to 1.8 dm3 per minute, and reaches DN 150. The device is offered in a compact and a remote version, always with HART and a two-line display with push buttons. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We can quote 10H sensors from the order code on your existing nameplate.

Notable properties of the 10H

  • Smallest bore of the Promag range, with PFA internal diameters of 2.25 mm at DN 2 and 4.5 mm at DN 4
  • Large list of hygienic process connections, from Tri-Clamp to DIN 11864 and SMS 1145
  • No pressure loss across the sensor, no moving parts
  • Two-line backlit-style display with push buttons for local setup
  • Compliance with IEC, EN and NAMUR as stated in the benefit list

Data table for 10H

Values originate from TI00095D. The flow table in the document continues beyond DN 4; only the two smallest sizes are quoted here because they show the instrument character best.

Parameter Value for 10H
Product root 10H, Proline Promag 10H (TI00095D, edition 16.18)
Positioning Flowmeter for smallest flow rates with a cost-effective transmitter
Liner PFA
Sensor housing Stainless steel (3-A, EHEDG on cover page)
Nominal diameters DN 2 to 150 (1/12 to 6 inch)
PFA internal diameter, DN 2 / 4 / 8 2.25 / 4.5 / 9.0 mm
PFA internal diameter, DN 15 / 1 inch 16.0 / 22.6 mm
Flow range DN 2 0.06 to 1.8 dm3/min (factory full scale 0.5 dm3/min)
Flow range DN 4 0.25 to 7 dm3/min (factory full scale 2 dm3/min)
Typical velocity range v = 0.01 to 10 m/s
Accuracy, pulse output Plus/minus 0.5 % of reading plus 2 mm/s; current output adds typically 5 microampere
Repeatability Max. 0.2 % of reading plus 2 mm/s
Minimum conductivity 50 microsiemens per cm
Medium temperature -20 to +150 degC with EPDM, FKM or Kalrez seals
Ambient temperature Transmitter -20 to +60 degC; sensor -40 to +60 degC
Pressure ratings PN 16 / PN 40 for the listed sizes
Supply 85 to 250 V AC; 20 to 28 V AC; 11 to 40 V DC
Power consumption Below 12 VA (AC 250 V), below 8 VA (AC 28 V), below 6 W (DC), including sensor
Protection class IP67 (NEMA 4X) for transmitter and sensor
Cleaning CIP and SIP
Weight, compact DN 2 to 15 3.6 to 3.7 kg; DN 25: 3.9 kg; DN 40: 5.5 kg; DN 50: 6.0 kg
Remote sensor weight DN 15 / 25 / 50 1.9 / 2.8 / 4.6 kg; wall-mount transmitter 3.1 kg

Using 10H in Gulf food, beverage and pharma plants

Milk standardization, flavor and vitamin dosing, enzyme feeds in bakeries and syrup lines in bottling halls are typical small-flow jobs. In the GCC, where dairy and juice plants run hot, washdown-heavy shifts, the stainless housing and IP67 rating help. Laboratories and pilot plants appreciate that a DN 2 or DN 4 meter keeps hold-up volume low.

Because it is an electromagnetic device, it only measures conductive liquids of at least 50 microsiemens per cm. In the remote version, the minimum conductivity also depends on the connecting cable length, as the datasheet notes.

How 10H differs from other Promag 10 variants

The other Promag 10 members target different pipes: 10W for water at up to DN 2000, 10P for chemical lines with a PTFE liner, 10L for lap-joint water mains, 10D for wafer installation and 10E for basic chemical use. The 10H is the one with a PFA liner, hygienic housing and sizes below DN 25. Its seal choice of EPDM, FKM or Kalrez allows up to 150 degC, higher than the 130 degC of 10P or the 110 degC of 10E.

Compared with the later Promag H 100 and H 300, the 10H has fewer outputs and no web server, which is exactly why it costs less to integrate.

Ordering notes for 10H

Match size, seal material and connection to the old nameplate. For O-ring seals the datasheet lists flange, ISO 228 and NPT couplings for DN 2 to 25. For aseptic gasket seals it lists welding nipples to EN 10357, ODT/SMS, ASME BPE and ISO 2037, Tri-Clamp, DIN 11851, DIN 11864-1, SMS 1145 and a DIN 11864-2 flange. Choose supply: 85 to 250 V AC, 20 to 28 V AC or 11 to 40 V DC.

Installation and checks for 10H

Install with the pipe full and keep electrodes wetted. Ground the sensor as described in the manual, and bring the supply cable to the correct terminals; at 250 V AC the switch-on current can reach 16 A for under 5 ms, so size the breaker accordingly. Do not leave the transmitter below -20 degC without protection because the display readability suffers.

Maintenance on 10H

Apart from regular gasket changes, the instrument needs no service. After a CIP cycle with strong caustic or acid, confirm that the seal material rated for the chemical is in place.

Documents and quotation

The datasheet attached is Technical Information TI00095D for the Promag 10H. Send an RFQ to Seven Star LLC with part number 10H, nominal diameter, seal and connection type, and quantity.

Delivery to Sites in Oman and the GCC

Delivery of the Endress+Hauser 10H is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive ultrasonic flowmeters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Selection Notes for the Endress+Hauser 10H

When comparing the Endress+Hauser 10H with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Endress+Hauser (E & H) ultrasonic flowmeters range and confirm the correct order code before you commit.

Other Models in the Promag 10 Range

Seven Star LLC supplies models from the Promag 10 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser 10E Promag 10E Economy PTFE FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 10D Promag 10D Compact Wafer FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 10P Promag 10P PTFE Electromagnetic FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 10W Promag 10W Water Electromagnetic FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 10H Promag 10H Sanitary Electromagnetic FlowmeterUltrasonic FlowmetersYou are viewing this model
Endress+Hauser 10L Promag 10L Lap-Joint Electromagnetic FlowmeterUltrasonic FlowmetersView details
Datasheets & Documents
  • PDF Datasheet Endress+Hauser 10H Promag 10H Sanitary Electromagnetic Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 10H Promag 10H Sanitary

Answers from our engineering team on installation, compatibility and integration.

01What liner does the 10H have?
A PFA liner inside a stainless steel sensor housing, which the cover page links to 3-A and EHEDG.
02What is the smallest size of the 10H?
DN 2 (1/12 inch) with a recommended flow range of 0.06 to 1.8 dm3 per minute; the series runs up to DN 150.
03How hot may the medium be for the 10H?
Minus 20 to plus 150 degC with EPDM, Viton (FKM) or Kalrez seals, according to TI00095D.
04Which supply voltages does the 10H accept?
85 to 250 V AC, 20 to 28 V AC, or 11 to 40 V DC, with power use up to 12 VA on the AC mains option.
05How do I quote the 10H?
Send an RFQ to Seven Star LLC with 10H, the order code or nameplate data, size, connection and quantity.