- Automation & ControlView all 2,896 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser 50W Promag 50W Water Electromagnetic Flowmeter
Description
50W: water meter with the modular Proline 50 transmitter
The Endress+Hauser 50W combines a water-and-wastewater electromagnetic sensor with the modular Proline 50 transmitter. TI00046D, which also covers the extended 53W, headlines flow measurement of liquids in water or wastewater applications and lists drinking water, wastewater and sewage sludge as typical media. The cover page claims flow up to 110 000 m3 per hour, fluid temperature up to 80 degC and process pressure up to 40 bar, with lengths in accordance with DVGW and ISO.
Compared with the simple Promag 10W, the 50W can speak PROFIBUS DP or PA, FOUNDATION Fieldbus or Modbus RS485 as well as HART, which matters in plants with a DCS already wired for fieldbus. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Capabilities of 50W
- Sensor sizes from DN 25 to DN 2000 with polyurethane or hard rubber liner
- Electrode choice of 1.4435, Alloy C-22 or tantalum for difficult water
- Minimum conductivity of only 5 microsiemens per cm
- Status input and configurable pulse output, backlit display with push buttons
- IP68 sensor option for the remote version
50W data sheet extract
| Parameter | Value for 50W |
|---|---|
| Product root | 50W, Proline Promag 50W (TI00046D, edition 13.17; same document covers 53W) |
| Application | Water, wastewater, drinking water, sewage sludge |
| Maximum flow | Up to 110 000 m3/h (484 315 gal/min) |
| Process pressure | Up to 40 bar (580 psi) |
| Fluid temperature | Up to +80 degC |
| Nominal diameters | DN 25 to 2000 (1 to 78 inch) |
| Polyurethane liner | -20 to +50 degC, DN 25 to 1200 |
| Hard rubber liner | 0 to +80 degC, DN 50 to 2000 |
| Electrodes | 1.4435, Alloy C-22 or tantalum |
| Minimum conductivity | 5 microsiemens per cm |
| Operable flow range | Over 1000 : 1 |
| Pulse output accuracy (Promag 50) | 0.5 % of reading plus 1 mm/s; optional 0.2 % plus 2 mm/s |
| Supply | 85 to 260 V AC; 20 to 55 V AC; 16 to 62 V DC (45 to 65 Hz on AC) |
| Fieldbus and signals | HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485 |
| Status input | 3 to 30 V DC, 5 kilohm, galvanically isolated; configurable for totalizer reset, value suppression, error reset |
| Current output | Active or passive, time constant 0.01 to 100 s, typical temperature coefficient 0.005 % of reading per degC |
| Flange standards | EN 1092-1, ASME B16.5, AWWA C207 Class D, JIS B2220, AS 2129 Table E, AS 4087 PN 16 |
| Ambient temperature, transmitter | -20 to +60 degC; optional -40 to +60 degC |
| Protection class | IP67 (NEMA 4X); optional IP68 (NEMA 6P) for remote sensor |
| Weight DN 25 compact / remote sensor | 7.3 kg / 5.3 kg |
Typical 50W installations in Oman
Water boards and industrial estates in the GCC often combine large-diameter transmission meters with PLC-based SCADA. The 50W fits: its fieldbus options reduce wiring, the status input can reset totalizers remotely, and the hard rubber liner up to DN 2000 suits large raw-water mains. Sewage sludge is called out on the cover, so abrasive slurries are within scope as long as the liner temperature limit is respected.
How 50W differs from other Promag 50 variants
Within the Promag 50 family, 50W uses rubber or polyurethane liners and goes up to DN 2000, whereas 50P uses PTFE or PFA for chemicals up to 180 degC, 50H is a small-bore sanitary meter with PFA, 50L is the lap-joint weight-optimized sensor to DN 2400, 50D is a polyamide wafer unit and 50E is the economy PTFE version. Against the cheaper Promag 10W, the 50W adds electrode choices including tantalum, minimum conductivity of 5 instead of 50 microsiemens per cm and fieldbus connectivity. The 53W in the same document has a better pulse-output accuracy of 0.2 percent of reading plus 2 mm/s as standard.
Ordering 50W
Read the nameplate: nominal diameter, liner, electrode material, flange standard and pressure rating, communication and supply. Keep in mind that the 5 microsiemens limit applies to fluids generally, while remote versions need the minimum conductivity reconsidered for cable length. For submerged chambers pick the remote design with the IP68 sensor.
Installing 50W
Mount with the pipe full, respect inlet and outlet runs, use grounding rings or disks for plastic pipe and maintain the ambient range of minus 20 to plus 60 degC (minus 40 optional). Do not bury the sensor without checking with the manufacturer, as the datasheet asks. Connect the supply and the output, then use the Quick Setup menus or the configuration tool.
Care of 50W
Check flange bolts, cable glands and the coating on carbon steel flanges. Compare totalizer values against the pump station log at intervals. Keep the replacement lining information with the asset file.
When a utility standardizes on one transmitter family, the 50W has an advantage: the modular Proline concept lets maintenance staff use the same menu structure on every Promag 50 meter, and the application-specific Quick Setup menus shorten commissioning. A spare transmitter board or housing can often be shared across sensors of different diameters, because the electronics are independent of the sensor size, while the sensor itself is matched by its calibration data and nameplate. This is why the nameplate code, not just the product name, should accompany every enquiry for spares.
Quick answers on 50W
The meter reads in both flow directions, so reverse flow in a looped main is measured and shown. The current output offers a selectable time constant from 0.01 to 100 seconds, which smooths pulsating pump flow. A status input of 3 to 30 V DC allows remote totalizer reset. If you need the highest accuracy, check the 53W data in the same document.
Documents and quotation
Technical Information TI00046D is the datasheet for the 50W. Send an RFQ to Seven Star LLC with part number 50W, nominal diameter, liner, flange standard, communication type and quantity.
Delivery to Sites in Oman and the GCC
Delivery of the Endress+Hauser 50W is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive ultrasonic flowmeters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.
Datasheets & Documents
- Datasheet Endress+Hauser 50W Promag 50W Water Electromagnetic Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser 50W Promag 50W Water Electromagnetic
Answers from our engineering team on installation, compatibility and integration.
01What is the 50W?
The water and wastewater member of the Promag 50 family, a bidirectional electromagnetic flowmeter with a modular Proline 50 transmitter.
02What sizes and liners does the 50W offer?
DN 25 to 2000, with polyurethane from minus 20 to plus 50 degC (to DN 1200) and hard rubber from 0 to plus 80 degC (DN 50 to 2000).
03Which communication options does the 50W list?
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus and Modbus RS485 are named on the cover of TI00046D.
04What conductivity does the 50W need?
At least 5 microsiemens per cm for fluids in general; the remote version also depends on the cable length.
05How do I quote the 50W?
Send an RFQ to Seven Star LLC with 50W, nominal diameter, liner, flange standard, communication type and quantity.