Brand: Endress+Hauser (E & H)
Endress+Hauser 10L Promag 10L Lap-Joint Electromagnetic Flowmeter
Description
10L: a lighter electromagnetic sensor for water lines
The Endress+Hauser 10L is described in TI00100D as the flowmeter with a weight-optimized sensor and high cost-effectiveness. It carries up to 30 percent less sensor weight than conventional designs and uses a lap-joint flange concept that lets the installer rotate the flange to line up bolt holes on pipes smaller than DN 350. The sensor range runs from DN 25 up to DN 2400, which is unusually large for a Promag 10 member, and a reduced installation length follows DVGW and ISO.
The datasheet describes the 10L as fully suitable for standard applications in the water and wastewater industry. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; this page helps buyers find the part when a plant register cites only the root 10L.
Features in short
- Lap-joint flanges below DN 350 that simplify alignment and reduce installation cost
- Three liners across the range: PTFE, polyurethane, hard rubber
- Two-line display with push buttons and HART, compact or remote transmitter
- Shortest practical installation length according to DVGW and ISO
- Galvanized carbon steel lap-joint flanges for corrosion protection
10L data from the datasheet
| Parameter | Value for 10L |
|---|---|
| Product root | 10L, Proline Promag 10L (TI00100D, edition 19.17) |
| Positioning | Weight-optimized sensor, highly cost-effective, for water and wastewater |
| Sensor weight | Up to 30 % less than a conventional sensor |
| Nominal diameters | DN 25 to 2400 (1 to 90 inch) |
| PTFE liner limits | -20 to +90 degC, DN 25 to 300 |
| Polyurethane liner limits | -20 to +50 degC, DN 25 to 1200 |
| Hard rubber liner limits | 0 to +80 degC, DN 350 to 2400 |
| Measuring tube | 1.4301/1.4306 (DN 25 to 300); 1.4301/1.4307 (DN 350 and up) |
| Electrodes | 1.4435 (316L) or Alloy C22, 2.4602 (UNS N06022) |
| Housing | Powder-coated die-cast aluminum for compact and wall-mounted transmitter |
| EN 1092-1 connection | Lap joint flange PN 10/16 up to DN 300; fixed flange PN 6/10 from DN 350 |
| ASME B16.5 | Lap joint Class 150 up to 12 inch; fixed Class 150 from 14 inch |
| AWWA C207 | Fixed flange Class D, 48 to 90 inch |
| Flange protection | Carbon steel lap joint flanges hot-dip galvanized |
| Accuracy, pulse output | 0.5 % of reading plus 2 mm/s |
| Minimum conductivity | 50 microsiemens per cm |
| Supply | 85 to 250 V AC; 20 to 28 V AC; 11 to 40 V DC |
| Ambient temperature | Transmitter -20 to +60 degC; carbon-steel-flange sensor -10 to +60 degC |
| Protection class | IP67 (type 4X); IP20 with housing open |
| Current output | 4 to 20 mA active, below 700 ohm (HART at least 250 ohm) |
Where 10L belongs in Gulf utilities
Large-bore sensors in desert regions are heavy and hard to lift into chambers; the weight advantage helps crews working with limited cranes. Typical places are water transmission lines, treated-sewage-effluent systems for landscape irrigation, reservoir feeds and pumping stations. Because the lap-joint design allows rotation, installers can fit the 10L between existing flanged pipework that is slightly misaligned.
Industrial plants also use it on cooling-water headers where the liner temperature limit is respected, which is 50 degC for polyurethane and 80 degC for hard rubber.
How 10L differs from other Promag 10 variants
The 10W has the same drinking-water focus but different construction: IP68 option, flanged sensors to DN 2000 and no lap-joint concept. The 10D is a short wafer meter limited to DN 100. The 10P and 10E are PTFE chemical meters to DN 600. Only the 10L reaches DN 2400 and offers PTFE in the small sizes together with rubber in the large ones. In the Promag 50 range the corresponding root is 50L, with a more capable transmitter, and the Promag L 400 (5L4B) adds a touch display and web server.
Ordering 10L
Select the nominal diameter and note the liner that the diameter implies: PTFE for DN 25 to 300, polyurethane up to DN 1200, hard rubber for DN 350 and above. Select the electrode material, then the standard: EN 1092-1 PN 10/16 lap joint, ASME B16.5, AWWA C207 Class D, AS 2129 or AS 4087. State the supply voltage and whether the transmitter is compact or wall mounted.
Installing and commissioning 10L
Slide the flanges into position, tighten the bolts evenly, and connect the ground. Keep the pipe full, and avoid air entrainment at high points. Observe that stamped-plate lap-joint flanges are only for PN 10. After powering up, set full scale and pulse value from the factory settings, which use v about 2.5 m/s for the current output.
Care of 10L
Inspect the galvanized flange coating after years of coastal exposure, touch up damage, and keep the transmitter cover sealed. The sensor has no moving parts, so no periodic recalibration is mandated by the document.
If the display becomes unreadable at low temperature, remember that the transmitter rating is minus 20 degC; in the Gulf this rarely matters, but it does for mountain pipelines in winter.
Quick answers on 10L
People ask whether the 10L can replace an older flanged meter. It can when the nominal diameter, face-to-face length and flange standard match, and because the sensor is lighter the existing pipe supports are normally adequate. They also ask about the transmitter: the compact housing and the wall-mounted housing are both powder-coated die-cast aluminum, the supply accepts 85 to 250 V AC, 20 to 28 V AC or 11 to 40 V DC, and the current output is galvanically isolated with a load below 700 ohm. The accuracy statement for the pulse output is 0.5 percent of reading plus 2 mm per second, repeatability is 0.2 percent of reading plus 2 mm per second, and the minimum conductivity of the liquid is 50 microsiemens per cm. In a remote version the sensor and wall-mounted transmitter are joined by a cable, and cable length counts against the conductivity requirement.
Finally, many buyers ask for the weight at a given size. The datasheet tables the weights per diameter for compact and remote versions and for each flange standard; please quote your size and standard and we will confirm it against the table before supply.
Documents and quotation
The datasheet is Technical Information TI00100D for the Promag 10L. Send an RFQ to Seven Star LLC with part number 10L, nominal diameter, liner, flange standard and quantity.
Other Models in the Promag 10 Range
Seven Star LLC supplies models from the Promag 10 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser 10E Promag 10E Economy PTFE Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 10D Promag 10D Compact Wafer Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 10P Promag 10P PTFE Electromagnetic Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 10W Promag 10W Water Electromagnetic Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 10H Promag 10H Sanitary Electromagnetic Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 10L Promag 10L Lap-Joint Electromagnetic Flowmeter | Ultrasonic Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser 10L Promag 10L Lap-Joint Electromagnetic Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser 10L Promag 10L Lap-Joint
Answers from our engineering team on installation, compatibility and integration.
01What makes the 10L different from a standard flanged meter?
It has a weight-optimized sensor, with up to 30 percent less weight, and a lap-joint flange concept below DN 350 for easy bolt-hole alignment.
02How large is the 10L range?
DN 25 to 2400, equal to 1 to 90 inch, with PTFE, polyurethane and hard rubber liners depending on diameter.
03What liner temperatures apply to the 10L?
PTFE minus 20 to 90 degC, polyurethane minus 20 to 50 degC, and hard rubber 0 to 80 degC, per TI00100D.
04Is the 10L suitable for drinking water?
The datasheet states it is suitable for standard applications in the water and wastewater industry; check the approvals for your region.
05How do I quote the 10L?
Send an RFQ to Seven Star LLC with 10L, nominal diameter, liner, flange standard and quantity.


















Reviews
There are no reviews yet.