Endress+Hauser 10W Promag 10W Water Electromagnetic Flowmeter

Description

Overview of the Endress+Hauser 10W

The 10W is the water and wastewater version of the Promag 10 generation. Technical Information TI00093D calls it the specialist for the most demanding water applications and highlights international drinking-water approvals plus a sensor with degree of protection IP68 (Type 6P enclosure) combined with a cost-effective transmitter. A robust, completely welded sensor is claimed to give reliable long-term operation.

It covers DN 25 to DN 2000, which makes it relevant to both building-service pipework and large transmission lines. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the 10W is quoted here against the nameplate data of the unit being replaced or extended.

What is built into the 10W

  • Two liner options: polyurethane for DN 25 to 1200, hard rubber for DN 50 to 2000
  • Optional IP68 for the remote sensor, for chambers that may flood
  • Flange connections to six standards including AWWA Class D and Australian AS 2129
  • Active 4 to 20 mA output with HART, plus a passive pulse or status output
  • Two-line display with push buttons, compact or remote construction

10W technical table

All entries come from TI00093D. Flow windows are the recommended range at v about 0.3 to 10 m/s.

Parameter Value for 10W
Product root 10W, Proline Promag 10W (TI00093D, edition 14.17)
Positioning Water and wastewater specialist, IP68 sensor option
Nominal diameters DN 25 to 2000 (1 to 78 inch)
Liners and limits Polyurethane -20 to +50 degC (DN 25 to 1200); hard rubber 0 to +80 degC (DN 50 to 2000)
Electrodes 1.4435 (316L) or Alloy C22
Measuring tube Stainless steel 1.4301 (304) or 1.4306 (304L) up to DN 300; same grades above
Sensor housing Powder-coated die-cast aluminum to DN 300; protective lacquering DN 350 to 2000
Flow DN 25 9 to 300 dm3/min (factory full scale 75 dm3/min)
Flow DN 32 15 to 500 dm3/min
Flow DN 40 25 to 700 dm3/min
Flow DN 50 35 to 1100 dm3/min
Flow DN 600 310 to 9600 m3/h
Accuracy, pulse output 0.5 % of reading plus 2 mm/s
Repeatability Max. 0.2 % of reading plus 2 mm/s
Minimum conductivity 50 microsiemens per cm
Flange standards EN 1092-1, ASME B16.5, AWWA C207 Class D, JIS B2220, AS 2129 Table E, AS 4087 PN 16
Electrode surface roughness 0.3 to 0.5 micrometer
Ambient temperature Transmitter -20 to +60 degC; sensor with carbon steel flanges -10 to +60 degC
Protection class IP67 (NEMA 4X) standard; optional IP68 (NEMA 6P) for the sensor of the remote version
Supply 85 to 250 V AC; 20 to 28 V AC or 11 to 40 V DC
Current output 4 to 20 mA active, load under 700 ohm (HART at least 250 ohm)
Pulse/status output Passive, 30 V DC, 250 mA
Weight compact / remote sensor DN 25 5.7 kg / 5.3 kg
Weight compact / remote sensor DN 50 (EN) 9.0 kg / 8.6 kg

Water duties for 10W around Oman

Municipal distribution, reservoir inlets, desalination permeate lines and irrigation schemes are the natural home for the 10W. In wastewater plants, hard rubber liners tolerate abrasive loads. Because the standard version is IP67 and the remote sensor can be ordered IP68, pump stations built below ground level can be metered without moving the electronics into the pit. For buried installations the datasheet asks users to contact the manufacturer.

Industrial users meter cooling water and process water in the same way, within the 50 degC or 80 degC liner limits.

How 10W differs from other Promag 10 variants

The largest difference is size range and liner: 10W reaches DN 2000 with rubber liners, while 10P (PTFE, DN 25 to 600) and 10E (PTFE, to DN 600) are chemical meters, 10L is the weight-optimized lap-joint line up to DN 2400, and 10D is a short wafer unit up to DN 100. Temperature separates them too: the 10W is limited to 50 degC with polyurethane and 80 degC with hard rubber, against 130 degC for the 10P.

Compared with Promag W 400 (5W4B), the 10W has no web server or touch display; it has a simple two-line display and HART.

Choosing a 10W configuration

Read size, liner, electrode material and flange standard from the nameplate. Alloy C22 electrodes are for aggressive wastewater, 316L for general use. Pay attention to the flange material list in the datasheet: carbon steel flanges are protected by Al/Zn coating up to DN 300 and by lacquering above. If the meter will be submerged, specify the remote version with the IP68 sensor.

Mounting the 10W

Keep the pipe full at the sensor location and respect straight-run advice. Both electrodes must stay in contact with liquid. With carbon steel flanges the sensor ambient limit is minus 10 degC. In remote versions, minimum conductivity requirement rises with cable length, so keep the connecting cable as short as practical.

Service of the 10W

Keep cable glands tight, check the grounding connection and watch for leaks at the flange. There are no moving parts.

For long-lived installations, record the liner type and flange standard on the asset register. If a replacement is needed years later, the combination of nominal diameter, liner and flange standard matters more than the product name. The electrode surface is specified at 0.3 to 0.5 micrometer roughness, which helps limit fouling in sewage service, and a periodic zero check with a full, stationary pipe confirms the electronics. Cleaning of electrodes is rarely required in clean water, yet sludge lines may need a periodic wash.

Documents and quotation

The datasheet for the 10W is Technical Information TI00093D. Send an RFQ to Seven Star LLC with part number 10W, nominal diameter, liner, flange standard and quantity.

Delivery to Sites in Oman and the GCC

Delivery of the Endress+Hauser 10W is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive ultrasonic flowmeters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Selection Notes for the Endress+Hauser 10W

When comparing the Endress+Hauser 10W with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Endress+Hauser (E & H) ultrasonic flowmeters range and confirm the correct order code before you commit.

Other Models in the Promag 10 Range

Seven Star LLC supplies models from the Promag 10 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser 10E Promag 10E Economy PTFE FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 10D Promag 10D Compact Wafer FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 10P Promag 10P PTFE Electromagnetic FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 10W Promag 10W Water Electromagnetic FlowmeterUltrasonic FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser 10W Promag 10W Water Electromagnetic Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 10W Promag 10W Water Electromagnetic

Answers from our engineering team on installation, compatibility and integration.

01What sizes does the 10W cover?
DN 25 to 2000, equal to 1 to 78 inch, with flow windows from 9 to 300 dm3/min at DN 25 up to 9 600 m3/h at DN 600.
02Which liners are available on the 10W?
Polyurethane at minus 20 to plus 50 degC for DN 25 to 1200 and hard rubber at 0 to plus 80 degC for DN 50 to 2000.
03Can the 10W be submerged?
The remote version can be ordered with an IP68 (NEMA 6P) sensor, while the standard degree of protection is IP67.
04What accuracy is given for the 10W?
Pulse output 0.5 percent of reading plus 2 mm/s, with repeatability up to 0.2 percent of reading plus 2 mm/s.
05How do I request the 10W?
Send an RFQ to Seven Star LLC with 10W, nominal diameter, liner and flange standard, and quantity.