Endress+Hauser 10D Promag 10D Compact Wafer Flowmeter

Description

What the 10D is

Endress+Hauser 10D is the compact wafer meter among the Promag 10 roots. TI00081D calls it highly cost-effective, offered as a compact wafer unit for basic water applications where space is limited or where the pipe is plastic. Its housing is designed so that the sensor centers itself quickly between the flanges, and ground disks are integrated, which spares the installer from fitting extra parts on plastic pipes.

The measuring tube is made of polyamide with EPDM O-rings, and the document lists international drinking-water approvals: WRAS BS 6920, ACS, NSF 61 and KTW/W270. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the 10D is available to quote by nameplate code.

Features of the 10D

  • Short installation length and total weights from 2.9 kg at DN 25
  • Integrated stainless steel ground disks
  • Wafer version for DN 25 to DN 100 and a threaded version for DN 25 to 50
  • Compact or remote construction, always with HART
  • Two-line display with push buttons

10D specification table

Parameter Value for 10D
Product root 10D, Proline Promag 10D (TI00081D, edition 14.16)
Design Compact wafer meter, short installation length, low weight
Target Basic water applications, limited space and plastic pipes
Wafer sizes DN 25, 40, 50, 65, 80, 100 (1 to 4 inch)
Threaded sizes DN 25, 40, 50 with G or NPT external thread
Measuring tube Polyamide with EPDM O-rings
Drinking-water approvals WRAS BS 6920, ACS, NSF 61, KTW/W270
Electrodes Two measuring electrodes, 1.4435 (316L)
Ground disks Integrated, stainless steel 1.4301 (304)
Medium temperature 0 to +60 degC (+32 to +140 degF)
Pressure ratings EN 1092-1 up to PN 16; ASME B16.5 up to Class 150; JIS B2220 up to 10 K; G external thread up to PN 16
Mounting bolts Galvanized steel 5.6 or 5.8; stainless A2-70
Minimum conductivity 50 microsiemens per cm
Supply 85 to 250 V AC; 20 to 28 V AC; 11 to 40 V DC
Ambient temperature Sensor and transmitter -20 to +60 degC
Protection class IP67 (NEMA 4X) for transmitter and sensor
Vibration resistance Acceleration up to 2 g per IEC 60068-2-6
Weight compact DN 25 / 40 / 50 2.9 / 3.5 / 4.3 kg total
Remote sensor / field transmitter DN 25 1.8 kg / 3.1 kg
Current output 4 to 20 mA active, below 700 ohm (HART at least 250 ohm)

Everyday uses for 10D in Oman and the GCC

Think of building services and small utilities: chilled water in district cooling substations, boiler make-up, reverse-osmosis permeate on a skid, irrigation pump sets and cooling towers. The low weight allows a pipe to carry the meter without extra supports, and PVC or HDPE pipes are welcome because the integrated ground disks provide the reference potential.

Since the medium temperature is limited to 60 degC, the 10D should not be used on hot water or condensate lines. For those jobs the PTFE versions are better.

How 10D differs from other Promag 10 variants

Compared with 10W, which is flanged and goes to DN 2000, the 10D is a wafer meter to DN 100 with a polyamide tube; its pressure limit is PN 16 rather than the higher ratings of flange-based sensors. Against the 10H hygienic meter it has no PFA liner and cannot be cleaned in place. Unlike 10L, 10P and 10E, the 10D has no liner at all in the usual sense: the measuring tube itself is the plastic part. The threaded versions with G or NPT external threads are unique to this root.

Selecting 10D

First decide between wafer and threaded. Wafer sensors fit EN 1092-1, ASME B16.5 and JIS B2220 flanges and use mounting bolts in galvanized steel (strength 5.6 or 5.8) or stainless A2-70. Threaded sensors are available for DN 25, 40 and 50. Then confirm the drinking-water approval needed in your market and choose the supply voltage. Send the complete code to Seven Star LLC.

Installation hints for 10D

Center the sensor between flanges using the housing guide, tighten bolts to the torque in the manual and connect the transmitter. Inlet runs follow the usual electromagnetic rules, and the pipe must be full. The ambient range of minus 20 to plus 60 degC applies to both transmitter and sensor, so shade outdoor installations in summer.

Servicing 10D

No moving parts and no wear parts beyond the O-rings. Replace those if the sensor is removed. A periodic check of the grounding path in plastic pipe installations is worthwhile.

Quick answers on 10D

A common question is whether the 10D can be fitted to a plastic pipe. The datasheet positions it for exactly that, since the ground disks are integrated and made of stainless steel 1.4301. Another is whether it tolerates vibration: it is rated for acceleration up to 2 g following IEC 60068-2-6. The third is the supply: 85 to 250 V AC at 45 to 65 Hz, 20 to 28 V AC, or 11 to 40 V DC. For a remote version, the sensor weighs 1.8 kg at DN 25 and the field-housing transmitter 3.1 kg, which is handy on small skids where a compact stack would be awkward.

The pressure statement matters too. Flanged wafer sensors are limited by the flange standard used, up to PN 16 for EN 1092-1, Class 150 for ASME B16.5 and 10 K for JIS B2220, while threaded versions with G external thread are good to PN 16. If your operating pressure is higher, select a flanged sensor from another Promag root.

Documents and quotation

Technical Information TI00081D is the datasheet for the 10D. Send an RFQ to Seven Star LLC with part number 10D, wafer or threaded type, nominal diameter and quantity.

Ordering Checklist for the Endress+Hauser 10D

Before you ask for a quotation for the Endress+Hauser 10D, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the ultrasonic flowmeters already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.

Installation and Commissioning Planning

Planning ahead shortens downtime when a Endress+Hauser 10D goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Endress+Hauser (E & H) equipment can be planned around it.

Other Models in the Promag 10 Range

Seven Star LLC supplies models from the Promag 10 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser 10E Promag 10E Economy PTFE FlowmeterUltrasonic FlowmetersView details
Endress+Hauser 10D Promag 10D Compact Wafer FlowmeterUltrasonic FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser 10D Promag 10D Compact Wafer Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 10D Promag 10D Compact Wafer

Answers from our engineering team on installation, compatibility and integration.

01What type of meter is the 10D?
A compact wafer electromagnetic meter for basic water applications, with integrated ground disks and a polyamide measuring tube.
02Which drinking-water approvals does the 10D list?
WRAS BS 6920, ACS, NSF 61 and KTW/W270, as stated in TI00081D.
03What sizes does the 10D cover?
Wafer DN 25, 40, 50, 65, 80 and 100, plus threaded versions in DN 25, 40 and 50 with G or NPT external threads.
04What is the medium temperature limit of the 10D?
0 to plus 60 degC (32 to 140 degF), so it is intended for cold and ambient water, not hot water.
05How do I quote the 10D?
Send an RFQ to Seven Star LLC with 10D, wafer or threaded version, nominal diameter and quantity.