Endress+Hauser 8I5B Promass I 500 Straight-Tube Coriolis Meter

Description

8I5B Promass I 500: straight-tube Coriolis flow with a remote transmitter

Among the Coriolis sensors made by Endress+Hauser, the 8I5B stands out for its straight, easy-to-clean titanium tube. TI01284D presents the Proline Promass I 500 as the version that combines in-line viscosity and flow measurement with a remote transmitter offering up to 4 I/Os. It uses TMB technology and a full-bore design, which the document links to minimal pressure loss and gentle treatment of the fluid.

That makes it a candidate for slurries, shear-sensitive products, pasty media and hygienic lines where a bent tube would trap residue. As an independent supplier serving Oman and the GCC, Seven Star LLC is not affiliated with the manufacturer; we quote the 8I5B on the strength of the complete order code you send.

Principal features of 8I5B

  • Straight single-tube system in titanium Grade 9, nominal diameters DN 8 to 80
  • Full-bore variants (15 FB to 50 FB) that raise flow capacity within the same line size
  • Immune to process influences, according to the datasheet
  • Optional in-line viscosity measurement through application package EG
  • Hygienic connection list including DIN 11864, Tri-Clamp and eccentric clamp
  • Backlit touch display, WLAN access and Heartbeat Technology

8I5B specification table

Values are quoted from TI01284D. Where the document prints two numbers for one nominal size, the first is the standard bore and the second the full-bore (FB) sensor.

Parameter Value for 8I5B
Product root 8I5B, Proline Promass I 500 (TI01284D, 2025-12-01)
Sensor design Straight single titanium tube, TMB technology, full-bore sizes available
Nominal diameters DN 8 to 80 (3/8 to 3 inch); full-bore: 15 FB, 25 FB, 40 FB, 50 FB
Full scale DN 8 0 to 2 000 kg/h
Full scale DN 15 / 15 FB 0 to 6 500 / 0 to 18 000 kg/h
Full scale DN 25 / 25 FB 0 to 18 000 / 0 to 45 000 kg/h
Full scale DN 40 / 40 FB 0 to 45 000 / 0 to 70 000 kg/h
Full scale DN 50 / 50 FB 0 to 70 000 / 0 to 180 000 kg/h
Full scale DN 80 0 to 180 000 kg/h
Liquid mass and volume flow accuracy Plus/minus 0.10 % of reading
Gas mass flow accuracy Plus/minus 0.50 % of reading
Liquid density accuracy 0.0005 g/cm3 reference; 0.02 g/cm3 standard; 0.004 g/cm3 with Special density package EE
Repeatability 0.05 % of reading for liquids; 0.25 % for gases
Medium temperature -50 to +150 degC (-58 to +302 degF)
Medium density 0 to 5 000 kg/m3
Materials Sensor 1.4301 (304); measuring tubes titanium Grade 9; process connections 1.4301, wetted parts titanium Grade 2
Process connections EN 1092-1 flanges, ASME B16.5, JIS B2220, DIN 11864-2, Tri-Clamp, eccentric Tri-Clamp, DIN 11851, SMS 1145, ISO 2853, DIN 11864-1
Clamp and SMS pressure limit Clamp connections up to 16 bar (232 psi); SMS 1145 up to 16 bar with suitable seals
Viscosity In-line, real-time dynamic viscosity with application package EG
Transmitter weight 1.4 kg digital polycarbonate; 2.4 kg digital aluminum; 6.5 kg aluminum; 15.6 kg cast stainless
Sensor weight, PN 40 flanges DN 8: 11 kg; DN 15: 13 kg; DN 15 FB: 19 kg
Hazardous area EPL Gb, Zone 1 in the measuring tube for listed versions
Current output 4 to 20 mA HART, 250 to 700 ohm load, 28.8 V open circuit active, damping 0 to 999.9 s

Where the 8I5B fits in Gulf process plants

Food, beverage and dairy producers in the GCC need a meter that survives CIP and does not hold product in dead pockets; the straight tube and the DIN 11864 and clamp couplings answer this. Pharmaceutical and personal-care plants use it for syrups and creams, while oil and gas facilities use it on viscous chemicals, lube-oil additives and drilling-mud components.

The viscosity package turns the meter into a quality sensor: a refinery blender or a paint plant can watch dynamic viscosity in real time instead of waiting for laboratory samples. Where the fluid is flammable, TI01284D lists approvals with equipment protection level Gb, Zone 1 in the measuring tube.

How 8I5B differs from other Promass I variants

The I 100 and I 300 integrate electronics in a compact or transmitter head; the 8I5B places a Proline 500 transmitter on a standard cable. The sizes show the clearest contrast with Promass H 500 (8H5B): that meter is limited to DN 50 and fixed flanges, while the 8I5B reaches DN 80 and adds full-bore sensors, with a DN 50 FB range of 0 to 180 000 kg/h. The temperature limit also differs, at 150 degC here against up to 205 degC for the zirconium H 500.

Density accuracy under special calibration is 0.004 g/cm3 for the I 500, against 0.002 g/cm3 for the H 500 with the same package.

Choosing the right 8I5B configuration

Select standard or full-bore according to how much flow the line must pass at the allowed pressure drop; the full-bore sensor trades some mass for a higher range. Verify the process connection against hygienic standards, and observe that clamp connections and SMS 1145 are limited to 16 bar. Choose housings (polycarbonate, aluminum or cast stainless) and decide whether the EG viscosity package is wanted; it must be selected when ordering. Send the whole order code with your RFQ.

Installing 8I5B and putting it into service

Mount the sensor so it remains filled and, for a curved tube, match orientation to the datasheet; here the tube is straight, which simplifies drainage. Observe a minimum distance of one device length between neighboring sensors in a series installation. Wire the remote cable, set the 4 to 20 mA current range and damping, and activate WLAN only during commissioning if site policy requires.

Servicing the 8I5B

Titanium wetted parts need little attention beyond periodic Heartbeat checks and gasket replacement. A zero adjustment is advised only in special cases, for instance at low flow, with very viscous media or with low-pressure gas. Record cleaning cycles to protect seals.

Documents and quotation

Technical Information TI01284D is the datasheet for this part number. Send an RFQ to Seven Star LLC with part number 8I5B, the order code, size, connection and quantity for a prompt reply.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser 8I5B Promass I 500 Straight-Tube Coriolis Meter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 8I5B Promass I 500 Straight-Tube

Answers from our engineering team on installation, compatibility and integration.

01What tube material does the 8I5B use?
The measuring tubes are titanium Grade 9, the sensor housing is 1.4301 (304) and process connection wetted parts are titanium Grade 2.
02Does the 8I5B measure viscosity?
Yes, with application package EG it measures dynamic viscosity in line and in real time alongside flow, density and temperature.
03What sizes are available for the 8I5B?
DN 8 to 80 (3/8 to 3 inch), including full-bore versions 15 FB, 25 FB, 40 FB and 50 FB with higher flow ranges.
04What is the medium temperature range of the 8I5B?
Minus 50 to plus 150 degC (minus 58 to plus 302 degF) according to TI01284D.
05How do I ask for a quote on the 8I5B?
Send an RFQ to Seven Star LLC with 8I5B, full order code, nominal size, connection type and quantity.