- Automation & ControlView all 3,006 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser 50D Promag 50D Compact Wafer Flowmeter
Description
50D and its role in small-bore water measurement
Endress+Hauser 50D is the compact wafer sensor of the Promag 50 range. TI00082D describes an electromagnetic flow measuring system for liquids in water or wastewater applications with a polyamide lining, fluid temperature up to 60 degC, process pressure up to 16 bar and flow up to 4 700 dm3 per minute. The cover page lists four drinking-water approvals: KTW/W270, WRAS BS 6920, ACS and NSF 61.
Where the 10D is a basic meter, the 50D carries the modular Proline 50 transmitter and can speak HART or PROFIBUS DP/PA. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We quote the 50D from the root on the nameplate.
50D traits
- Short wafer construction with a compact design
- Polyamide measuring tube and EPDM O-rings
- Four international drinking-water approvals
- Minimum conductivity of 5 microsiemens per cm
- HART or PROFIBUS communication with a status input
50D numbers from the datasheet
| Parameter | Value for 50D |
|---|---|
| Product root | 50D, Proline Promag 50D (TI00082D, edition 13.11) |
| Application | Drinking water and wastewater |
| Maximum flow | Up to 4 700 dm3/min (1 250 gal/min) |
| Fluid temperature | 0 to +60 degC (+32 to +140 degF) |
| Process pressure | Up to 16 bar (232 psi) |
| Lining | Polyamide measuring tube, EPDM O-rings |
| Drinking-water approvals | KTW/W270, WRAS BS 6920, ACS, NSF 61 |
| Pressure ratings | EN 1092-1 PN 16; ANSI B16.5 Class 150; JIS B2220 10 K |
| Electrodes | Two measuring electrodes in 1.4435 (316L) |
| Ground disks | 1.4301 (304) |
| Mounting bolts | Galvanized steel 5.6 or 5.8; stainless A2-70 |
| Minimum conductivity | 5 microsiemens per cm; 20 for demineralized water |
| Pulse output accuracy | 0.5 % of reading plus 1 mm/s |
| Supply | 85 to 260 V AC; 20 to 55 V AC; 16 to 62 V DC (HART, PROFIBUS DP) |
| Communication | HART and PROFIBUS DP/PA |
| Housings | Powder-coated die-cast aluminum for sensor and transmitter |
| Ambient temperature | Sensor and transmitter -20 to +60 degC |
| Protection class | IP67 (NEMA 4X) |
| Vibration | Acceleration up to 2 g per IEC 60068-2-6 |
Typical places for 50D in Oman
District cooling substations, building water services, small water treatment skids, pump stations and irrigation systems regularly need a neat, low-cost wafer meter that can be bolted between flanges. The 50D fits where the water is cold and the pressure moderate, and its integrated ground disks make plastic pipes practical. Since it is approved for drinking water, it can also be used on potable supply branches subject to local rules.
How 50D differs from other Promag 50 variants
The 50D is the smallest and lightest of the Promag 50 sensors; its medium temperature ceiling of 60 degC compares with 80 degC for 50W, 110 degC for 50E and 180 degC for 50P, and its pressure limit of 16 bar compares with 40 bar for 50W and 50P. It has no PTFE or rubber liner: the polyamide tube itself carries the medium. Against the 10D, it offers PROFIBUS and the modular transmitter but shares the polyamide tube and approvals, so the sensor itself is similar.
Choosing a 50D
Match diameter and flange family: the wafer sensor accepts EN 1092-1 PN 16, ANSI B16.5 Class 150 and JIS B2220 10 K flanges. Choose between mounting bolts in galvanized steel and in stainless A2-70. Decide on HART or PROFIBUS and the supply voltage. Provide the nameplate code in your RFQ to Seven Star LLC.
Mounting the 50D
Position the sensor between the flanges using the housing guides so it is centered, tighten bolts evenly, and keep the pipe full at all times. The ambient temperature for sensor and transmitter is minus 20 to plus 60 degC, so shade outdoor installations. In remote versions, cable length affects the minimum conductivity that can be measured, which matters for demineralized water.
Maintenance for 50D
No moving parts. If the sensor is dismounted, replace the O-rings. Check the cable glands for moisture and keep the transmitter cover closed.
The electrical side follows the Proline 50 concept used across the range. The current output can be set active or passive, is galvanically isolated and has a selectable time constant, so a small pump station with pulsating flow can be damped. The status input accepts 3 to 30 V DC and can reset totalizers, suppress measured values or clear error messages. For the HART and PROFIBUS DP versions the supply is 85 to 260 V AC, 20 to 55 V AC or 16 to 62 V DC, which means one transmitter variant can serve both mains-powered and 24 V DC cabinets. The sensor weight is low because the housing is die-cast aluminum and the tube is polyamide, so the pipe rarely needs additional supports.
For procurement, record the diameter, the flange family (EN 1092-1 PN 16, ANSI Class 150 or JIS 10 K), the bolt grade and the communication type before sending the enquiry. These four items identify the sensor and transmitter combination without ambiguity and avoid a second round of questions about mounting hardware, which is a frequent cause of delay for wafer meters.
Quick answers on 50D
People ask about accuracy: pulse output is 0.5 percent of reading plus 1 mm per second, with current output adding typically 5 microampere. They also ask about vibration, which the document limits to acceleration of 2 g following IEC 60068-2-6, and about protection, which is IP67 for transmitter and sensor. The supply for HART and PROFIBUS DP versions is 85 to 260 V AC, 20 to 55 V AC or 16 to 62 V DC.
Documents and quotation
Technical Information TI00082D is the datasheet for the 50D. Send an RFQ to Seven Star LLC with part number 50D, nominal diameter, communication type and quantity.
Installation and Commissioning Planning
Planning ahead shortens downtime when a Endress+Hauser 50D goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Endress+Hauser (E & H) equipment can be planned around it.
Other Models in the Promag 50 Range
Seven Star LLC supplies models from the Promag 50 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser 50W Promag 50W Water Electromagnetic Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 50L Promag 50L Lap-Joint Electromagnetic Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 50E Promag 50E Economy PTFE Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 50D Promag 50D Compact Wafer Flowmeter | Ultrasonic Flowmeters | You are viewing this model |
| Endress+Hauser 50H Promag 50H Hygienic Electromagnetic Flowmeter | Ultrasonic Flowmeters | View details |
Datasheets & Documents
- Datasheet Endress+Hauser 50D Promag 50D Compact Wafer Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser 50D Promag 50D Compact Wafer
Answers from our engineering team on installation, compatibility and integration.
01What is the 50D?
A compact wafer electromagnetic flowmeter from the Promag 50 range, with a polyamide lining and four drinking-water approvals.
02What is the maximum temperature and pressure for the 50D?
Fluid temperature up to plus 60 degC and process pressure up to 16 bar (232 psi), per the cover page of TI00082D.
03Which approvals are listed for the 50D?
The cover page of TI00082D lists KTW/W270, WRAS BS 6920, ACS and NSF 61 as drinking-water approvals.
04Which communication does the 50D offer?
HART and PROFIBUS DP/PA are listed as connections to the process control system.
05How do I quote the 50D?
Send an RFQ to Seven Star LLC with 50D, nominal diameter, communication type and quantity.


















Reviews